The sanitary smart level switch (SIS) is used for signaling high and low positions in tanks or pipelines within the production process. Its compact design makes it easy to transport and install, even in confined spaces or challenging working conditions. It is suitable for use in CIP and SIP cleaning applications, with surface roughness (Ra) adjustable to customer requirements. It is ideal for applications in the pharmaceutical and food industries.
Main Features:
Applications:
Technical Data:
Type | Standard (Standard / Extended / Mini) | Rear Installation | Explosion Proof |
---|---|---|---|
Range (optional) | Water-based, oil-based, powder, two-phase (e.g., oil-water), liquid in distributing systems (e.g., bubbles) | Powdered substances | |
Ambient Temperature | -40...85°C | -40…80°C | -20…70°C |
Process Temperature | Continuous: max. 100°C, for ambient temperature -40…85°C Short period (1 hour): max. 150°C (mini max 135°C for ambient temperature -40…60°C) |
-40…80°C | Max. 100°C, for ambient temperature |
Nominal Voltage | 18…30V DC | ||
Current Consumption | Max. 50mA | ||
Surge Voltage Category | Surge Voltage Category II | ||
Surge Current Protection | Yes | ||
Relay Input (optional) | 2 relays: 1. NO type, 2. NC type | ||
Output Type | PNP/NPN (optional) | ||
Relay Time Function | <1s (maximum 60s) | ||
PNP/NPN Output Time Function | Max. 100mA | Max. 50mA | |
Output Voltage Drop | Max. 2.5V | ||
Reverse Polarity Protection | Yes, short impulse | ||
Short Circuit Protection | Yes | ||
Connector | M12 4-pin | ||
Wetted Material | SUS316 / SUS316L | ||
Process Pressure | 10-40 bar | ||
Nut Specification | G ½” | M32*P1.5 | G ½” |
IP Rating | IP67/IP68 | ||
Probe Material/Surface Roughness | PEEK/Ra<0.8 | PEEK-1000/Ra<0.8 | |
Housing Protection (optional) | IP67/IP68/IP69K (underwater at 1 meter, IP68 can withstand 30 days) | ||
LED Indicator | Yellow LED for activation, green LED for reset | ||
Output Simulation Test | Magnetic test (apply magnet to + for 2 seconds, output will switch) | ||
Digital Communication | IO Link V1.1 | ||
Explosion-Proof Certification | - |
Наличност: Моля, обърнете внимание, че този продукт не е на склад
Можете да направите предварителна поръчка, да отчетете интерес към даден продукт, като кликнете върху бутона „Попитайте за наличност“.
Трябва да сте влезли
The sanitary smart level switch (SIS) is used for signaling high and low positions in tanks or pipelines within the production process. Its compact design makes it easy to transport and install, even in confined spaces or challenging working conditions. It is suitable for use in CIP and SIP cleaning applications, with surface roughness (Ra) adjustable to customer requirements. It is ideal for applications in the pharmaceutical and food industries.
Main Features:
Applications:
Technical Data:
Type | Standard (Standard / Extended / Mini) | Rear Installation | Explosion Proof |
---|---|---|---|
Range (optional) | Water-based, oil-based, powder, two-phase (e.g., oil-water), liquid in distributing systems (e.g., bubbles) | Powdered substances | |
Ambient Temperature | -40...85°C | -40…80°C | -20…70°C |
Process Temperature | Continuous: max. 100°C, for ambient temperature -40…85°C Short period (1 hour): max. 150°C (mini max 135°C for ambient temperature -40…60°C) |
-40…80°C | Max. 100°C, for ambient temperature |
Nominal Voltage | 18…30V DC | ||
Current Consumption | Max. 50mA | ||
Surge Voltage Category | Surge Voltage Category II | ||
Surge Current Protection | Yes | ||
Relay Input (optional) | 2 relays: 1. NO type, 2. NC type | ||
Output Type | PNP/NPN (optional) | ||
Relay Time Function | <1s (maximum 60s) | ||
PNP/NPN Output Time Function | Max. 100mA | Max. 50mA | |
Output Voltage Drop | Max. 2.5V | ||
Reverse Polarity Protection | Yes, short impulse | ||
Short Circuit Protection | Yes | ||
Connector | M12 4-pin | ||
Wetted Material | SUS316 / SUS316L | ||
Process Pressure | 10-40 bar | ||
Nut Specification | G ½” | M32*P1.5 | G ½” |
IP Rating | IP67/IP68 | ||
Probe Material/Surface Roughness | PEEK/Ra<0.8 | PEEK-1000/Ra<0.8 | |
Housing Protection (optional) | IP67/IP68/IP69K (underwater at 1 meter, IP68 can withstand 30 days) | ||
LED Indicator | Yellow LED for activation, green LED for reset | ||
Output Simulation Test | Magnetic test (apply magnet to + for 2 seconds, output will switch) | ||
Digital Communication | IO Link V1.1 | ||
Explosion-Proof Certification | - |