The cast resin current transformer is capable to withstanding the aggravate outdoor environmental condition. The current transformer is maintenance-free and only mountable in vertical situation. The secondary windings are used for measurement and / or protection purposes, or for special use like testing winding.
Design | Cast-resin insulated |
---|---|
Colour | brown |
In accordance to | VDE 0414; IEC 60044; ANSI C 57.13; BS 1675 |
Class of insulation | B |
Ith: | 1000 x IN (max. 100 kA); |
Idyn | 2.5 x ITh (max. 125 kA) |
Frequency | 50-60 Hz, other frequency on request |
Rated insulation voltage: | complying with the standard |
Primary currenty | see table |
Secondary current: | 5A; 1A; other current on request |
Burde / Class | depending on the number of cores, accuracy limit factors and the rated output |
Secondary terminal box | with degree of protection IP64 |
Special model: | Secondary switch-over |
Type |
IGWF 12
|
IGWF 24
|
IGWF 12
|
IGWF 24
|
IGWF 36
|
---|---|---|---|---|---|
Insulation voltage [kV] | 12/28/75 | 24/50/125 | 12/28/75 | 24/50/125 | 36/70/170 |
Max. Ipn [A] | 1250 | 1250 | 2500 | 2500 | 2500 |
Creepage distance [mm] | 560 | 560 | 610 | 780 | 1120 |
Max. number of cores | 2 | 2 | 5 | 5 | 5 |
Weight [kg] | 25 | 25 | 40 | 48 | 72 |
Type | A | B | C | D | E | Sec. Terminals | Shield |
---|---|---|---|---|---|---|---|
IGWF 12/24 B 27 |
250 | 180 | 325 | 310 | 240 | 6 | 7 |
IGWF 12 E 43 |
350 | 248 | 325 | 442 | 340 | 10 | 3 |
IGWF 24 E 44 |
350 | 248 | 375 | 442 | 340 | 10 | 4 |
IGWF 36 E 46 |
350 | 248 | 475 | 442 | 340 | 10 | 6 |
Интересувате ли се от този продукт? Имате ли нужда от допълнителна информация или индивидуални цени?
Трябва да сте влезли
The cast resin current transformer is capable to withstanding the aggravate outdoor environmental condition. The current transformer is maintenance-free and only mountable in vertical situation. The secondary windings are used for measurement and / or protection purposes, or for special use like testing winding.
Design | Cast-resin insulated |
---|---|
Colour | brown |
In accordance to | VDE 0414; IEC 60044; ANSI C 57.13; BS 1675 |
Class of insulation | B |
Ith: | 1000 x IN (max. 100 kA); |
Idyn | 2.5 x ITh (max. 125 kA) |
Frequency | 50-60 Hz, other frequency on request |
Rated insulation voltage: | complying with the standard |
Primary currenty | see table |
Secondary current: | 5A; 1A; other current on request |
Burde / Class | depending on the number of cores, accuracy limit factors and the rated output |
Secondary terminal box | with degree of protection IP64 |
Special model: | Secondary switch-over |
Type |
IGWF 12
|
IGWF 24
|
IGWF 12
|
IGWF 24
|
IGWF 36
|
---|---|---|---|---|---|
Insulation voltage [kV] | 12/28/75 | 24/50/125 | 12/28/75 | 24/50/125 | 36/70/170 |
Max. Ipn [A] | 1250 | 1250 | 2500 | 2500 | 2500 |
Creepage distance [mm] | 560 | 560 | 610 | 780 | 1120 |
Max. number of cores | 2 | 2 | 5 | 5 | 5 |
Weight [kg] | 25 | 25 | 40 | 48 | 72 |
Type | A | B | C | D | E | Sec. Terminals | Shield |
---|---|---|---|---|---|---|---|
IGWF 12/24 B 27 |
250 | 180 | 325 | 310 | 240 | 6 | 7 |
IGWF 12 E 43 |
350 | 248 | 325 | 442 | 340 | 10 | 3 |
IGWF 24 E 44 |
350 | 248 | 375 | 442 | 340 | 10 | 4 |
IGWF 36 E 46 |
350 | 248 | 475 | 442 | 340 | 10 | 6 |