Текущи трансформатори за разпределителни устройства - SVA170

The SVA170 is specially designed for application in medium voltage installations as Ring Main Units. This cast measuring transformer is cost effective and very reliable. Multi-core and multi ratio types are available in measuring and protection classes.


Environmental conditionss
This product is designed to be safe under the following conditions:
Location: Indeoor use
Ambient temperature: -5°C .. +40°C
Relative humidity: 5% .. 85%, non condensing
Protection drgree IP20
Suitable for: Cables, bus-bar
Application conditions
Standard: IEC 60044-1
Rated short-time thermal current(lth) 60 x In/1s
Continuous thermal current (lth) 100%
Rated insulation level: 0,72/3/-kv
Rated frequency: 50/60Hz
Class of insulation: E
Primary current 30-1000A
Primaty windows dimensions: Ø 110mm
Secondary terminal Screw terminals (max. 2Nm)
Wire diameter max. 6mm² solid max 4mm² stranded


 

Ratio Class Burden Articele number
100/1A 10P10 2VA 106532

Wiring diagram

Przekładniki prądowe do rozdzielnic - SVA170  schemat podłączenia

Przekładniki prądowe do rozdzielnic - SVA170 wentylatory

Изпратете запитване

Интересувате ли се от този продукт? Имате ли нужда от допълнителна информация или индивидуални цени?

Свържете се с нас
ПОИСКАЙТЕ ПРОДУКТА close
Благодарим ви, че изпратихте съобщението си. Ние ще отговорим възможно най-скоро.
ПОИСКАЙТЕ ПРОДУКТА close
Преглед

Добави към списъка с желания

Трябва да сте влезли

The SVA170 is specially designed for application in medium voltage installations as Ring Main Units. This cast measuring transformer is cost effective and very reliable. Multi-core and multi ratio types are available in measuring and protection classes.


Environmental conditionss
This product is designed to be safe under the following conditions:
Location: Indeoor use
Ambient temperature: -5°C .. +40°C
Relative humidity: 5% .. 85%, non condensing
Protection drgree IP20
Suitable for: Cables, bus-bar
Application conditions
Standard: IEC 60044-1
Rated short-time thermal current(lth) 60 x In/1s
Continuous thermal current (lth) 100%
Rated insulation level: 0,72/3/-kv
Rated frequency: 50/60Hz
Class of insulation: E
Primary current 30-1000A
Primaty windows dimensions: Ø 110mm
Secondary terminal Screw terminals (max. 2Nm)
Wire diameter max. 6mm² solid max 4mm² stranded


 

Ratio Class Burden Articele number
100/1A 10P10 2VA 106532