The biggest advantage of split core current transformers is their easy installation. They could be mounted on the various conductors without the need to disconnect the grid.
There are 4 types of protection CT for measuring up to 5000A in classes: 5P5, 5P10 i 5P15.
Type | Ratio | Code | |||||
---|---|---|---|---|---|---|---|
VA | 5P5 | VA | 5P10 | VA | 5P15 | ||
TAA032 21x32 | 200/5A | 2 | TAA032200K05 | ||||
250/5A | 2,5 | TAA032250K05 | |||||
300/5A | 2,5 | TAA032300K05 | |||||
400/5A | 5 | TAA032400K05 | |||||
TAA082 50x81 | 400/5A | 3 | TAA082400K05 | ||||
500/5A | 4 | TAA082500K05 | |||||
600/5A | 5 | TAA082600K05 | |||||
800/5A | 3 | TAA082800K05 | 1 | TAA082800L05 | |||
1000/5A | 5 | TAA0821K0K05 | 1 | TAA0821K0L05 | |||
TAA122 80,5x120 | 800/5A | 3 | TAA122800K05 | 1 | TAA122800L05 | ||
1000/5A | 5 | TAA1221K0K05 | 1 | TAA1221K0L05 | |||
1200/5A | 5 | TAA1221K2K05 | 1 | TAA1221K2L05 | |||
1500/5A | 7 | TAA1221K5K05 | 1 | TAA1221K5L05 | |||
TAA162 80,5x161 | 1000/5A | 20 | TAA1621K0K05 | 6 | TAA1621K0L05 | 1 | TAA1621K0M05 |
1500/5A | 25 | TAA1621K5K05 | 10 | TAA1621K5L05 | 1 | TAA1621K5M05 | |
2000/5A | 45 | TAA1622K0K05 | 15 | TAA1622K0L05 | 3 | TAA1622K0M05 | |
2500/5A | 50 | TAA1622K5K05 | 15 | TAA1622K5L05 | 2 | TAA1622K5M05 | |
3000/5A | 60 | TAA1623K0K05 | 20 | TAA1623K0L05 | 2 | TAA1623K0M05 | |
4000/5A | 80 | TAA1624K0K05 | 25 | TAA1624K0L05 | 2 | TAA1624K0M05 | |
5000/5A | 100 | TAA1625K0K05 | 30 | TAA1625K0L05 | 2 | TAA1625K0M05 |
Technical data
Self estinguishing | UL94-V0 |
---|---|
Thermoplastic material | 50-60Hz |
Insulation reference voltage | 0.72V |
Test voltage | 3 kV 1min. 50 Hz |
Insulation | E |
Protection degree | IP 20 |
Continous overcurrent | 1,2 In |
Rated short-time thermal current (Ith) | 60 In |
Rated dynamic current (I dyn) | 2.5 x I th |
Safety factor | N < 5 |
Operating temperature | -5 +50 ˚C |
Storage temperature | -20 +80 ˚C |
Manufactured according to | IEC/EN 6044-1, VDE, BS, UTE |
Integrated secondary terminals | 6 mm2 |
Sealable termina covers | integrated |
Supplied accessories:
- busbar fixing
- Insulated protective caps for busbar mounting
- C.T. fixing wall mounting fixing feet
Primary and secondary connections marking
Options
Vibration proof version |
VACXXXAVB |
Tropicalisation |
VACXXXTRP |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
Интересувате ли се от този продукт? Имате ли нужда от допълнителна информация или индивидуални цени?
Трябва да сте влезли
The biggest advantage of split core current transformers is their easy installation. They could be mounted on the various conductors without the need to disconnect the grid.
There are 4 types of protection CT for measuring up to 5000A in classes: 5P5, 5P10 i 5P15.
Type | Ratio | Code | |||||
---|---|---|---|---|---|---|---|
VA | 5P5 | VA | 5P10 | VA | 5P15 | ||
TAA032 21x32 | 200/5A | 2 | TAA032200K05 | ||||
250/5A | 2,5 | TAA032250K05 | |||||
300/5A | 2,5 | TAA032300K05 | |||||
400/5A | 5 | TAA032400K05 | |||||
TAA082 50x81 | 400/5A | 3 | TAA082400K05 | ||||
500/5A | 4 | TAA082500K05 | |||||
600/5A | 5 | TAA082600K05 | |||||
800/5A | 3 | TAA082800K05 | 1 | TAA082800L05 | |||
1000/5A | 5 | TAA0821K0K05 | 1 | TAA0821K0L05 | |||
TAA122 80,5x120 | 800/5A | 3 | TAA122800K05 | 1 | TAA122800L05 | ||
1000/5A | 5 | TAA1221K0K05 | 1 | TAA1221K0L05 | |||
1200/5A | 5 | TAA1221K2K05 | 1 | TAA1221K2L05 | |||
1500/5A | 7 | TAA1221K5K05 | 1 | TAA1221K5L05 | |||
TAA162 80,5x161 | 1000/5A | 20 | TAA1621K0K05 | 6 | TAA1621K0L05 | 1 | TAA1621K0M05 |
1500/5A | 25 | TAA1621K5K05 | 10 | TAA1621K5L05 | 1 | TAA1621K5M05 | |
2000/5A | 45 | TAA1622K0K05 | 15 | TAA1622K0L05 | 3 | TAA1622K0M05 | |
2500/5A | 50 | TAA1622K5K05 | 15 | TAA1622K5L05 | 2 | TAA1622K5M05 | |
3000/5A | 60 | TAA1623K0K05 | 20 | TAA1623K0L05 | 2 | TAA1623K0M05 | |
4000/5A | 80 | TAA1624K0K05 | 25 | TAA1624K0L05 | 2 | TAA1624K0M05 | |
5000/5A | 100 | TAA1625K0K05 | 30 | TAA1625K0L05 | 2 | TAA1625K0M05 |
Technical data
Self estinguishing | UL94-V0 |
---|---|
Thermoplastic material | 50-60Hz |
Insulation reference voltage | 0.72V |
Test voltage | 3 kV 1min. 50 Hz |
Insulation | E |
Protection degree | IP 20 |
Continous overcurrent | 1,2 In |
Rated short-time thermal current (Ith) | 60 In |
Rated dynamic current (I dyn) | 2.5 x I th |
Safety factor | N < 5 |
Operating temperature | -5 +50 ˚C |
Storage temperature | -20 +80 ˚C |
Manufactured according to | IEC/EN 6044-1, VDE, BS, UTE |
Integrated secondary terminals | 6 mm2 |
Sealable termina covers | integrated |
Supplied accessories:
- busbar fixing
- Insulated protective caps for busbar mounting
- C.T. fixing wall mounting fixing feet
Primary and secondary connections marking
Options
Vibration proof version |
VACXXXAVB |
Tropicalisation |
VACXXXTRP |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |