Трябва да сте влезли в
Category
https://www.dacpol.eu/pl/naprawy-i-modernizacje
Снимките са само с информационна цел. Вижте спецификацията на продукта
please use latin characters
With the offered active differential probe voltages up to 600V can be connected to the Bode 100. Since the measurement input of the probe is potential free it is possible to avoid grounding problems and to measure circuits which input and output have no common ground.
Key features:
Rated data:
Bandwidth | DC…25MHz (-3dB) |
---|---|
Ratio | 1/10 or 1/100 |
Accuracy | ±2% |
Input impedance | 4MΩ, 5.5pF |
Rise time | 14ns |
Input voltage (differential range) | ±70V (DC + Peak AC) lub 70VRMS – 1/10 ±700V (DC + Peak AC) lub 700VRMS– 1/100 |
Input voltage (common mode range) | ±700V (DC + Peak AC) lub 700VRMS1/10 i 1/100 |
Absolute max. voltage | ±1400V (DC + Peak AC) lub 1000VRMS CAT III1/10 i 1/100 |
Swing | ±7V (load 50kΩ) |
Offset | <±5mV |
Noise | 0.7mVRMS |
Source impedance | 1Ω at 1kHz, 8Ω at 1MHz |
CMRR | -86dB at 50Hz, -66dB at 20kHz |
Operating temperature | -10…40°C |
Storage temperature | -30…70°C |
Humidity | 25…85% RH |
DC input voltage range | 5…10V DC |
Polarity | “+” inside, “-“ outside, protect against wrong polarity |
Mains adapter | 9V DC/40mA |
Batteries | 4xAA |
Weight | <0.5kg |
Dimensions probe | 170x63x21mm |
Интересувате ли се от този продукт? Имате ли нужда от допълнителна информация или индивидуални цени?
Трябва да сте влезли
With the offered active differential probe voltages up to 600V can be connected to the Bode 100. Since the measurement input of the probe is potential free it is possible to avoid grounding problems and to measure circuits which input and output have no common ground.
Key features:
Rated data:
Bandwidth | DC…25MHz (-3dB) |
---|---|
Ratio | 1/10 or 1/100 |
Accuracy | ±2% |
Input impedance | 4MΩ, 5.5pF |
Rise time | 14ns |
Input voltage (differential range) | ±70V (DC + Peak AC) lub 70VRMS – 1/10 ±700V (DC + Peak AC) lub 700VRMS– 1/100 |
Input voltage (common mode range) | ±700V (DC + Peak AC) lub 700VRMS1/10 i 1/100 |
Absolute max. voltage | ±1400V (DC + Peak AC) lub 1000VRMS CAT III1/10 i 1/100 |
Swing | ±7V (load 50kΩ) |
Offset | <±5mV |
Noise | 0.7mVRMS |
Source impedance | 1Ω at 1kHz, 8Ω at 1MHz |
CMRR | -86dB at 50Hz, -66dB at 20kHz |
Operating temperature | -10…40°C |
Storage temperature | -30…70°C |
Humidity | 25…85% RH |
DC input voltage range | 5…10V DC |
Polarity | “+” inside, “-“ outside, protect against wrong polarity |
Mains adapter | 9V DC/40mA |
Batteries | 4xAA |
Weight | <0.5kg |
Dimensions probe | 170x63x21mm |
Your review appreciation cannot be sent
Report comment
Report sent
Your report cannot be sent
Напишете свой отзив
Review sent
Your review cannot be sent