The current transformer for self powered relay in SVR109 housing is specially designed for application in medium voltage installations as Ring Main Units (RMU). This solid, cast resin transformer is cost effective and very reliable. The transformer is fitted lengthwise with the cable. The transformer is provided with a permanent lead with connector for connection to the relay. The standard connector code is FKCVR 2.5/4-ST . The transformers are specially designed for dynamic loads and applicable for the so called self powered relays like Woodward SEG, WIC1 and others.
Rated data
Location | Indoor use |
---|---|
Protection degree | IP20 |
Rated frequency | 50/60Hz |
Insulation class | E (120°C) |
Primary window sutable for cable | Ø73mm |
Material | PU i PA6.6 |
Secondart terminal | Cable 110mm with connector FKCVR 2.5/4-ST |
Test winding | 0.288A |
Burden | Contact manufacturer for details |
Current range | Class | Cable diameter | Number |
---|---|---|---|
16-56A | 5P80 | 73mm |
4G2115N |
16-56A | 10P80 | 73mm |
4G2111N |
32-112A | 5P80 | 73mm |
4G2112N |
64-224A | 5P80 | 73mm |
4G2113N |
128-448A | 5P80 | 73mm |
4G2114N |
Connection diagram
Dimensions
Интересувате ли се от този продукт? Имате ли нужда от допълнителна информация или индивидуални цени?
Трябва да сте влезли
The current transformer for self powered relay in SVR109 housing is specially designed for application in medium voltage installations as Ring Main Units (RMU). This solid, cast resin transformer is cost effective and very reliable. The transformer is fitted lengthwise with the cable. The transformer is provided with a permanent lead with connector for connection to the relay. The standard connector code is FKCVR 2.5/4-ST . The transformers are specially designed for dynamic loads and applicable for the so called self powered relays like Woodward SEG, WIC1 and others.
Rated data
Location | Indoor use |
---|---|
Protection degree | IP20 |
Rated frequency | 50/60Hz |
Insulation class | E (120°C) |
Primary window sutable for cable | Ø73mm |
Material | PU i PA6.6 |
Secondart terminal | Cable 110mm with connector FKCVR 2.5/4-ST |
Test winding | 0.288A |
Burden | Contact manufacturer for details |
Current range | Class | Cable diameter | Number |
---|---|---|---|
16-56A | 5P80 | 73mm |
4G2115N |
16-56A | 10P80 | 73mm |
4G2111N |
32-112A | 5P80 | 73mm |
4G2112N |
64-224A | 5P80 | 73mm |
4G2113N |
128-448A | 5P80 | 73mm |
4G2114N |
Connection diagram
Dimensions