Objective: Heat a 0.50” (12.7)mm brass insert for debonding application.


Frequency: 215 kHz


Equipment:
  • Ambrell 2kW induction heating system, equipped with a remote heat station containing two 0.66μF capacitors for a total capacitance of 1.32μF;
  • An induction heating coil designed and developed specifically for this application.

Material: Intake manifold and 0.50” (12.7)mm diameter brass insert.


Temperature: 500 °F (260 °C)


Process:

A four-turn two-position helical coil is used to debond the inserts from the plastic. The coil is placed against the manifold and power is applied to the two inserts for 15 seconds to soften the plastic. Power is turned off and a threaded steel screw is inserted into the parts and the inserts are easily removed from the manifold.
This debonding process is for recycling 10,000 defective parts that QES has received the contract for debond the brass from the plastic and recycle the plastic. Induction makes it possible to simultaneously heat both inserts for removal saving time in the recycle process.


Benefits:
  • Rapid and accurate placement of heat;
  • Faster process time;
  • Consistent and repeatable results;
  • Easier removal of inserts;
  • Even distribution of heating.

Zašlete dotaz

Máte zájem o tento produkt? Potřebujete další informace nebo individuální ceny?

Kontaktujte nás
ZEPTEJTE SE O PRODUKT close
Děkujeme za zaslání zprávy. Odpovíme co nejdříve.
ZEPTEJTE SE O PRODUKT close
Procházet

Přidat do seznamu přání

musíš být přihlášen

Debonding inserts in manifolds for recycling


Objective: Heat a 0.50” (12.7)mm brass insert for debonding application.


Frequency: 215 kHz


Equipment:
  • Ambrell 2kW induction heating system, equipped with a remote heat station containing two 0.66μF capacitors for a total capacitance of 1.32μF;
  • An induction heating coil designed and developed specifically for this application.

Material: Intake manifold and 0.50” (12.7)mm diameter brass insert.


Temperature: 500 °F (260 °C)


Process:

A four-turn two-position helical coil is used to debond the inserts from the plastic. The coil is placed against the manifold and power is applied to the two inserts for 15 seconds to soften the plastic. Power is turned off and a threaded steel screw is inserted into the parts and the inserts are easily removed from the manifold.
This debonding process is for recycling 10,000 defective parts that QES has received the contract for debond the brass from the plastic and recycle the plastic. Induction makes it possible to simultaneously heat both inserts for removal saving time in the recycle process.


Benefits:
  • Rapid and accurate placement of heat;
  • Faster process time;
  • Consistent and repeatable results;
  • Easier removal of inserts;
  • Even distribution of heating.