The cast resin current transformer is capable to withstanding the aggravate outdoor environmental condition. The current transformer is maintenance-free and only mountable in vertical situation. The secondary windings are used for measurement and / or protection purposes, or for special use like testing winding.
Design | Cast-resin insulated |
---|---|
Colour | brown |
In accordance to | VDE 0414; IEC 60044; ANSI C 57.13; BS 1675 |
Class of insulation | B |
Ith: | 1000 x IN (max. 100 kA); |
Idyn | 2.5 x ITh (max. 125 kA) |
Frequency | 50-60 Hz, other frequency on request |
Rated insulation voltage: | complying with the standard |
Primary currenty | see table |
Secondary current: | 5A; 1A; other current on request |
Burde / Class | depending on the number of cores, accuracy limit factors and the rated output |
Secondary terminal box | with degree of protection IP64 |
Special model: | Secondary switch-over |
Type |
IGWF 12
|
IGWF 24
|
IGWF 12
|
IGWF 24
|
IGWF 36
|
---|---|---|---|---|---|
Insulation voltage [kV] | 12/28/75 | 24/50/125 | 12/28/75 | 24/50/125 | 36/70/170 |
Max. Ipn [A] | 1250 | 1250 | 2500 | 2500 | 2500 |
Creepage distance [mm] | 560 | 560 | 610 | 780 | 1120 |
Max. number of cores | 2 | 2 | 5 | 5 | 5 |
Weight [kg] | 25 | 25 | 40 | 48 | 72 |
Type | A | B | C | D | E | Sec. Terminals | Shield |
---|---|---|---|---|---|---|---|
IGWF 12/24 B 27 |
250 | 180 | 325 | 310 | 240 | 6 | 7 |
IGWF 12 E 43 |
350 | 248 | 325 | 442 | 340 | 10 | 3 |
IGWF 24 E 44 |
350 | 248 | 375 | 442 | 340 | 10 | 4 |
IGWF 36 E 46 |
350 | 248 | 475 | 442 | 340 | 10 | 6 |
Máte zájem o tento produkt? Potřebujete další informace nebo individuální ceny?
musíš být přihlášen
The cast resin current transformer is capable to withstanding the aggravate outdoor environmental condition. The current transformer is maintenance-free and only mountable in vertical situation. The secondary windings are used for measurement and / or protection purposes, or for special use like testing winding.
Design | Cast-resin insulated |
---|---|
Colour | brown |
In accordance to | VDE 0414; IEC 60044; ANSI C 57.13; BS 1675 |
Class of insulation | B |
Ith: | 1000 x IN (max. 100 kA); |
Idyn | 2.5 x ITh (max. 125 kA) |
Frequency | 50-60 Hz, other frequency on request |
Rated insulation voltage: | complying with the standard |
Primary currenty | see table |
Secondary current: | 5A; 1A; other current on request |
Burde / Class | depending on the number of cores, accuracy limit factors and the rated output |
Secondary terminal box | with degree of protection IP64 |
Special model: | Secondary switch-over |
Type |
IGWF 12
|
IGWF 24
|
IGWF 12
|
IGWF 24
|
IGWF 36
|
---|---|---|---|---|---|
Insulation voltage [kV] | 12/28/75 | 24/50/125 | 12/28/75 | 24/50/125 | 36/70/170 |
Max. Ipn [A] | 1250 | 1250 | 2500 | 2500 | 2500 |
Creepage distance [mm] | 560 | 560 | 610 | 780 | 1120 |
Max. number of cores | 2 | 2 | 5 | 5 | 5 |
Weight [kg] | 25 | 25 | 40 | 48 | 72 |
Type | A | B | C | D | E | Sec. Terminals | Shield |
---|---|---|---|---|---|---|---|
IGWF 12/24 B 27 |
250 | 180 | 325 | 310 | 240 | 6 | 7 |
IGWF 12 E 43 |
350 | 248 | 325 | 442 | 340 | 10 | 3 |
IGWF 24 E 44 |
350 | 248 | 375 | 442 | 340 | 10 | 4 |
IGWF 36 E 46 |
350 | 248 | 475 | 442 | 340 | 10 | 6 |
Vaše hodnocení nelze odeslat