Properties:
• Two element diode power block with water radiator
• Water cooling
Typical applications:
• rectifiers,
• power supplies
Options:
• clamp assembled K-1 – Drawing. 1
• clamp assembled K-2 – Drawing. 2
• clamp assembled K-3 – Drawing. 3
• Thermal protection
• RC circuit
• fuse
Power block selection:
• There are different semiconductors used, depending on the load. Used semiconductor size is given in the Table 1.
Operation conditions:
One element power blocks are used in power electronic systems
• Cooling water temperature 50 C do 300 C at ambient air temperature > -100 C
• Atmospheric pressure 860hPa do 1060hPa
Drawing 1
|
Drawing 2
|
![]() |
![]() |
Drawing 3
|
|
![]()
|
Module type | Mean current IF(AV) [A] | Blocking voltage U RRM [V] |
Overcurrent I FSM [A] |
Semiconductor size [mm] |
Block Weight [kg] |
---|---|---|---|---|---|
MOC75W | 800…1400 | 400…2200 | 8000… 12000 | ![]() |
1,4 |
MOC7W | 450…650 | 400…3000 | 7000…10000 | ![]() |
1,6 |
MOC8W | 630…1000 | 400…6000 | 10000…24000 | ![]() |
1,6 |
MOC9W | 1000…3000 | 400…6000 | 20000…42000 | ![]() |
3,2 |
MOC11W | 2000…4000 | 400…7200 | 27000…65000 | ![]() |
9,8 |
Máte zájem o tento produkt? Potřebujete další informace nebo individuální ceny?
musíš být přihlášen
Properties:
• Two element diode power block with water radiator
• Water cooling
Typical applications:
• rectifiers,
• power supplies
Options:
• clamp assembled K-1 – Drawing. 1
• clamp assembled K-2 – Drawing. 2
• clamp assembled K-3 – Drawing. 3
• Thermal protection
• RC circuit
• fuse
Power block selection:
• There are different semiconductors used, depending on the load. Used semiconductor size is given in the Table 1.
Operation conditions:
One element power blocks are used in power electronic systems
• Cooling water temperature 50 C do 300 C at ambient air temperature > -100 C
• Atmospheric pressure 860hPa do 1060hPa
Drawing 1
|
Drawing 2
|
![]() |
![]() |
Drawing 3
|
|
![]()
|
Module type | Mean current IF(AV) [A] | Blocking voltage U RRM [V] |
Overcurrent I FSM [A] |
Semiconductor size [mm] |
Block Weight [kg] |
---|---|---|---|---|---|
MOC75W | 800…1400 | 400…2200 | 8000… 12000 | ![]() |
1,4 |
MOC7W | 450…650 | 400…3000 | 7000…10000 | ![]() |
1,6 |
MOC8W | 630…1000 | 400…6000 | 10000…24000 | ![]() |
1,6 |
MOC9W | 1000…3000 | 400…6000 | 20000…42000 | ![]() |
3,2 |
MOC11W | 2000…4000 | 400…7200 | 27000…65000 | ![]() |
9,8 |