

Musíte být přihlášen
Category
Montaż urządzeń
Modernizacja induktorów
Urządzenia indukcyjne
asd
Fotografie slouží pouze pro informační účely. Zobrazit specifikaci produktu
please use latin characters
Properties:
• Two element power diode block with both side cooling– RY
• Natural cooling
Typical applications:
• rectifiers, converters, supplies.
• DC power regulators
• power contactors
• soft-starts
Options:
• Standard – Diagram. 1
• Execution with current busses
• With blacken radiator
• Thermal protection
• RC circuit
• fuse
• forced cooling
Power block selection:
• There are different semiconductors used, depending on the load. Used semiconductor size is given in the Table 1.
Operation conditions:
One element power blocks are used in power electronic systems.
• Ambient air temperature -100 C - +400 C;
• Atmospheric pressure 860hPa do 1060hPa;
• Humidity less then 80% @ temperature 400 C
• Cooling air without aggressive factors.
Module type | Mean current IF(AV) [A] | Blocking voltage U RRM [V] |
Overcurrent I FSM [A] |
Semiconductor size [mm] |
Block Weight [kg] |
---|---|---|---|---|---|
M2C7P | 450…650 | 400…2400 | 7000…10000 | ![]() |
6,9 |
M2C8P | 630…1000 | 400…8500 | 10000…24000 | ![]() |
6,9 |
M2C9P | 1000…2000 | 400…7500 | 20000…42000 | ![]() |
16,4 |
M2C11P | 1000…3200 | 400…6000 | 27000…65000 | ![]() |
18,30 |
Máte zájem o tento produkt? Potřebujete další informace nebo individuální ceny?
musíš být přihlášen
Properties:
• Two element power diode block with both side cooling– RY
• Natural cooling
Typical applications:
• rectifiers, converters, supplies.
• DC power regulators
• power contactors
• soft-starts
Options:
• Standard – Diagram. 1
• Execution with current busses
• With blacken radiator
• Thermal protection
• RC circuit
• fuse
• forced cooling
Power block selection:
• There are different semiconductors used, depending on the load. Used semiconductor size is given in the Table 1.
Operation conditions:
One element power blocks are used in power electronic systems.
• Ambient air temperature -100 C - +400 C;
• Atmospheric pressure 860hPa do 1060hPa;
• Humidity less then 80% @ temperature 400 C
• Cooling air without aggressive factors.
Module type | Mean current IF(AV) [A] | Blocking voltage U RRM [V] |
Overcurrent I FSM [A] |
Semiconductor size [mm] |
Block Weight [kg] |
---|---|---|---|---|---|
M2C7P | 450…650 | 400…2400 | 7000…10000 | ![]() |
6,9 |
M2C8P | 630…1000 | 400…8500 | 10000…24000 | ![]() |
6,9 |
M2C9P | 1000…2000 | 400…7500 | 20000…42000 | ![]() |
16,4 |
M2C11P | 1000…3200 | 400…6000 | 27000…65000 | ![]() |
18,30 |
Vaše hodnocení nelze odeslat
Nahlásit komentář
Zpráva odeslána
Váš podnět nelze odeslat
Napište svůj názor
Zkontrolovat před odesláním
Vaši recenzi nelze odeslat