Current setting range | 0,03...10,0A (co 0,01A) |
---|---|
current accuracy | +/- 5% v.m. / rdg +/- 1 dgt |
Delay setting range | 0,03...5,00s (co 0,01sec) |
Delay accuracy | 5% |
Operating frequency | 47...63Hz |
Third harmonic filter | Osłabienie 88% @ 150Hz |
Operation characteristic | Typ A wg.IEC775 |
Toroid connection test | Ciągła |
Trip contact | SPDT, 5A 250Vac |
Alarm contact | SPDT, 5A 250Vac |
Operating temperature | 0...+50°C, U.R. / R.H. <90% n.c. |
Storage temperature | -20...+70°C |
Insulation | 2kV 50Hz, 1 min. |
Connections | faston 6,3 x 0,8 mm |
Thermoplastic material | UL 94V0 |
Protection for housing | IP52 |
Protection for terminals | IP20 |
According to | IEC 60947-2 |
TYPE |
X96DD |
---|
Characteristics to be specified | |||
---|---|---|---|
Aux. supply voltage | Standard | Va.c. (±10%, 45÷65Hz, 3VA) | 115 - 230 V |
On demand with extraprice |
Va.c. (±10%, 45÷65Hz, 3VA) 115 - 230 V | 24V; 48V; 400V | |
Vd.c. (-15...+20%, 3W) | 24V; 48V; 110V; 220V | ||
Va.c./d.c. (5VA/5W) | 20÷60V; 80÷260V |
DESCRIPTION
The X...DD series earth leakage relays are designedto measure the leakage or unbalance currents caused by conductors or appliances insulation losses and to react, in case the set limits are exceeded, switching off the power supply to thedefective system. Thanks to their distinctive feature (the displaying of the leakage current) it is possible to continuously monitor the insulation state and to program the preventive maintenance in order to avoid unexpected power breaks. Main features:
Dimension
Connection diagram
Máte zájem o tento produkt? Potřebujete další informace nebo individuální ceny?
musíš být přihlášen
Current setting range | 0,03...10,0A (co 0,01A) |
---|---|
current accuracy | +/- 5% v.m. / rdg +/- 1 dgt |
Delay setting range | 0,03...5,00s (co 0,01sec) |
Delay accuracy | 5% |
Operating frequency | 47...63Hz |
Third harmonic filter | Osłabienie 88% @ 150Hz |
Operation characteristic | Typ A wg.IEC775 |
Toroid connection test | Ciągła |
Trip contact | SPDT, 5A 250Vac |
Alarm contact | SPDT, 5A 250Vac |
Operating temperature | 0...+50°C, U.R. / R.H. <90% n.c. |
Storage temperature | -20...+70°C |
Insulation | 2kV 50Hz, 1 min. |
Connections | faston 6,3 x 0,8 mm |
Thermoplastic material | UL 94V0 |
Protection for housing | IP52 |
Protection for terminals | IP20 |
According to | IEC 60947-2 |
TYPE |
X96DD |
---|
Characteristics to be specified | |||
---|---|---|---|
Aux. supply voltage | Standard | Va.c. (±10%, 45÷65Hz, 3VA) | 115 - 230 V |
On demand with extraprice |
Va.c. (±10%, 45÷65Hz, 3VA) 115 - 230 V | 24V; 48V; 400V | |
Vd.c. (-15...+20%, 3W) | 24V; 48V; 110V; 220V | ||
Va.c./d.c. (5VA/5W) | 20÷60V; 80÷260V |
DESCRIPTION
The X...DD series earth leakage relays are designedto measure the leakage or unbalance currents caused by conductors or appliances insulation losses and to react, in case the set limits are exceeded, switching off the power supply to thedefective system. Thanks to their distinctive feature (the displaying of the leakage current) it is possible to continuously monitor the insulation state and to program the preventive maintenance in order to avoid unexpected power breaks. Main features: