Diferenciální sondy 1: 10/1: 100
  • Diferenciální sondy 1: 10/1: 100

Fotografie slouží pouze pro informační účely. Zobrazit specifikaci produktu

please use latin characters

Výrobce: OMICRON Lab

Diferenciální sondy 1: 10/1: 100

1:10/1:100 Differential Probe

With the offered active differential probe voltages up to 600V can be connected to the Bode 100. Since the measurement input of the probe is potential free it is possible to avoid grounding problems and to measure circuits which input and output have no common ground.

 

Key features:

  • Enables measurements in circuits with high voltages up to 700Vrms
  • Avoids grounding problems
  • CAT III compliant measurement input (maximum input voltage 1000Vrms)
  • CE compliant
  • Powered by mains adapter or battery cells
  • Can be perfectly used with the Bode 100

Rated data:

Bandwidth DC…25MHz (-3dB)
Ratio 1/10 or 1/100
Accuracy ±2%
Input impedance 4MΩ, 5.5pF
Rise time 14ns
Input voltage (differential range) ±70V (DC + Peak AC) lub 70VRMS – 1/10
±700V (DC + Peak AC) lub 700VRMS– 1/100
Input voltage (common mode range) ±700V (DC + Peak AC) lub 700VRMS1/10 i 1/100
Absolute max. voltage ±1400V (DC + Peak AC) lub 1000VRMS CAT III1/10 i 1/100
Swing ±7V (load 50kΩ)
Offset <±5mV
Noise 0.7mVRMS
Source impedance 1Ω at 1kHz, 8Ω at 1MHz
CMRR -86dB at 50Hz, -66dB at 20kHz
Operating temperature -10…40°C
Storage temperature -30…70°C
Humidity 25…85% RH
DC input voltage range 5…10V DC
Polarity “+” inside, “-“ outside, protect against wrong polarity
Mains adapter 9V DC/40mA
Batteries 4xAA
Weight <0.5kg
Dimensions probe 170x63x21mm

Zašlete dotaz

Máte zájem o tento produkt? Potřebujete další informace nebo individuální ceny?

Kontaktujte nás
ZEPTEJTE SE O PRODUKT close
Děkujeme za zaslání zprávy. Odpovíme co nejdříve.
ZEPTEJTE SE O PRODUKT close
Procházet

Přidat do seznamu přání

musíš být přihlášen

1:10/1:100 Differential Probe

With the offered active differential probe voltages up to 600V can be connected to the Bode 100. Since the measurement input of the probe is potential free it is possible to avoid grounding problems and to measure circuits which input and output have no common ground.

 

Key features:

  • Enables measurements in circuits with high voltages up to 700Vrms
  • Avoids grounding problems
  • CAT III compliant measurement input (maximum input voltage 1000Vrms)
  • CE compliant
  • Powered by mains adapter or battery cells
  • Can be perfectly used with the Bode 100

Rated data:

Bandwidth DC…25MHz (-3dB)
Ratio 1/10 or 1/100
Accuracy ±2%
Input impedance 4MΩ, 5.5pF
Rise time 14ns
Input voltage (differential range) ±70V (DC + Peak AC) lub 70VRMS – 1/10
±700V (DC + Peak AC) lub 700VRMS– 1/100
Input voltage (common mode range) ±700V (DC + Peak AC) lub 700VRMS1/10 i 1/100
Absolute max. voltage ±1400V (DC + Peak AC) lub 1000VRMS CAT III1/10 i 1/100
Swing ±7V (load 50kΩ)
Offset <±5mV
Noise 0.7mVRMS
Source impedance 1Ω at 1kHz, 8Ω at 1MHz
CMRR -86dB at 50Hz, -66dB at 20kHz
Operating temperature -10…40°C
Storage temperature -30…70°C
Humidity 25…85% RH
DC input voltage range 5…10V DC
Polarity “+” inside, “-“ outside, protect against wrong polarity
Mains adapter 9V DC/40mA
Batteries 4xAA
Weight <0.5kg
Dimensions probe 170x63x21mm