Characteristic
TYPICAL APPLICATIONS
MODEL | ACP 3003_3 | ACP 6003_3 |
---|---|---|
Current Ranges | 30 / 300 / 3000A | 60 / 600 / 6000A |
Output Sensitivity | 100mV / 10mV / 1mV / A | 50mV / 5mV / 0.5mV / A |
Linearity | ± 0.2% of reading | |
Basic Accuracy | ± 1% of reading ± 0.1A (30A, 60A) | |
± 1% of reading ± 1A (300A/3000A, 600A/6000A) | ||
Conductor position sensitivity | ± 2% of reading | |
Frequency Range (-1dB) | 10Hz do 20kHz | |
Phase shift (45 – 65Hz) | < 1 degrees | |
Load Impedance | > 100 kΩ | |
Output connection | 3 x 0.5m coax terminated with safety male BNC connector |
Technical data
ENVIRONMENTAL DATA
Operating Temperature | -20°C to 65°C |
Temperature Coefficient | ± 0.15% of reading per °C |
Storage Temperature (without battery) | -40°C do 75°C |
POWER SUPPLY
Battery type | 2 x AA MN 1500 LR6 Alkaline |
Battery life | 1000 hours continuous |
External Power Supply | 3V / 100mA |
MECHANICAL DATA
Dimensions (mm) | 110 (W) x 65 (S) x 23 (G) |
Probe Lengths | 610mm (24”), 915mm (36”) 1220mm(48”) |
Cable length | 2m (Probe to Integrator) |
SAFETY
EN61010-2-032:2002,
UL 610101, 2nd Edition, 2005-07-22
CAN/CSA-22.2 No. 61010-1, 2 nd Edition 2004-07
1000V, Measurement Category III, Pollution Degree 2.
EMC Standard EN 61326-2-2:2006
MAXIMUM SAFE VOLTAGES
1000V AC RMS or DC (Probe and Integrator)
POWER SUPPLY 30 Volts max (Output)
All accuracies stated at 23°C ± 1°C
High Accuracy and Wide Dynamic Range
Advanced coupling design results in minimal effect of external magnetic fields and off-centre conductor positioning on probe accuracy.
EN61010-2-032:2002 and EMC Conformance
Safety features provide the user with confidence when making measurements in hazardous voltage areas.
Conformance to EMC standards ensures high reliability through reduced susceptibility to electromagnetic interference.
![]() |
DEGREE OF PROTECTION
|
Máte zájem o tento produkt? Potřebujete další informace nebo individuální ceny?
musíš být přihlášen
Characteristic
TYPICAL APPLICATIONS
MODEL | ACP 3003_3 | ACP 6003_3 |
---|---|---|
Current Ranges | 30 / 300 / 3000A | 60 / 600 / 6000A |
Output Sensitivity | 100mV / 10mV / 1mV / A | 50mV / 5mV / 0.5mV / A |
Linearity | ± 0.2% of reading | |
Basic Accuracy | ± 1% of reading ± 0.1A (30A, 60A) | |
± 1% of reading ± 1A (300A/3000A, 600A/6000A) | ||
Conductor position sensitivity | ± 2% of reading | |
Frequency Range (-1dB) | 10Hz do 20kHz | |
Phase shift (45 – 65Hz) | < 1 degrees | |
Load Impedance | > 100 kΩ | |
Output connection | 3 x 0.5m coax terminated with safety male BNC connector |
Technical data
ENVIRONMENTAL DATA
Operating Temperature | -20°C to 65°C |
Temperature Coefficient | ± 0.15% of reading per °C |
Storage Temperature (without battery) | -40°C do 75°C |
POWER SUPPLY
Battery type | 2 x AA MN 1500 LR6 Alkaline |
Battery life | 1000 hours continuous |
External Power Supply | 3V / 100mA |
MECHANICAL DATA
Dimensions (mm) | 110 (W) x 65 (S) x 23 (G) |
Probe Lengths | 610mm (24”), 915mm (36”) 1220mm(48”) |
Cable length | 2m (Probe to Integrator) |
SAFETY
EN61010-2-032:2002,
UL 610101, 2nd Edition, 2005-07-22
CAN/CSA-22.2 No. 61010-1, 2 nd Edition 2004-07
1000V, Measurement Category III, Pollution Degree 2.
EMC Standard EN 61326-2-2:2006
MAXIMUM SAFE VOLTAGES
1000V AC RMS or DC (Probe and Integrator)
POWER SUPPLY 30 Volts max (Output)
All accuracies stated at 23°C ± 1°C
High Accuracy and Wide Dynamic Range
Advanced coupling design results in minimal effect of external magnetic fields and off-centre conductor positioning on probe accuracy.
EN61010-2-032:2002 and EMC Conformance
Safety features provide the user with confidence when making measurements in hazardous voltage areas.
Conformance to EMC standards ensures high reliability through reduced susceptibility to electromagnetic interference.
![]() |
DEGREE OF PROTECTION
|