The characteristics of NA003 as a good grid and system protector:
Iconography that presents where NA003 have to be installed:
Rated data:
Supply circuit | |
---|---|
Terminals | A1 (L), A2 (N) |
Supply voltage | DC: 24V AC: 110-230V |
Supply voltage tolerance | DC: ±10% AC: ±30% |
Rated frequency | 50/60Hz |
Tolerance of rated frequency | 48 – 63Hz |
Rated surge voltage | 4kV |
Measuring circuit | |
Terminals | L1, L2, L3, N |
Measuring input | 3x400V AC |
Measurand | line to line voltage, line to neutral voltage, 10 minutes average voltage, frequency, rate of change of frequency (RoCoF), phase shift (PShift) |
Measuring ranges | |
Line to line voltage | 0-560V AC |
Line to neutral voltage | 0-325V AC |
Frequency | 40-60Hz |
RoCoF | 100mHz/s-2Hz/s |
PShift | 1-15° |
Digital inputs | |
Terminals | I1 i ⊥, I2 i ⊥, I3 i ⊥, I4/I5 i ⊥ |
Type of contact | potential free |
Min. switching voltage/current | 24V/5mA |
Output circuit | |
Terminals | 11-12-14; 21-22-24; 31-32-34; |
Number of contacts | 3 changeover |
Contact material | AgNi |
Rated current | 5A/250V AC |
Electrical endurance | 100x103switching cycles (AC-1) |
Mechanical endurance | 15x106switching cycles |
Accuracy | |
Base accuracy (voltage) | <0,5% @ 25°C |
Temperature influence | <0,01%/°C |
Resolution | 10mV |
Base accuracy (frequency) | <0,01 Hz dla 25°C |
Temperature influence | <0,00002Hz/°C |
Resolution | 1mHz |
Isolation data | |
Rated insulation voltage | 400V |
Supply circuit/measuring circuit | protective separation |
Supply circuit/output circuit | protective separation |
Supply circuit/digital inputs | protective separation |
Output circuit/measuring circuit | protective separation |
Output circuit/digital inputs | protective separation |
Environmental conditions | |
Ambient temperature operation | -25…55°C |
Ambient temperature storage | -40…70°C |
Ambient temperature display | -15…55°C |
Relative humidity | 5…95% (non-condensing) |
Weight | 300g |
Electrical connection | |
Wire size | max. 2,5mm2 |
Stripping length | max. 8mm |
Electrical strength | max. 450V/16A (digital inputs, relay outputs) max. 750V/16A (measuring inputs) |
Torque | max. 0,5Nm |
Screw | M3, slotted recess for screw driver 0,6 x 3,5mm |
Sealing wire | dMAX = 0,8mm |
In order to ensure the proper function during power failures, an external UPS has to be used.
Máte zájem o tento produkt? Potřebujete další informace nebo individuální ceny?
musíš být přihlášen
The characteristics of NA003 as a good grid and system protector:
Iconography that presents where NA003 have to be installed:
Rated data:
Supply circuit | |
---|---|
Terminals | A1 (L), A2 (N) |
Supply voltage | DC: 24V AC: 110-230V |
Supply voltage tolerance | DC: ±10% AC: ±30% |
Rated frequency | 50/60Hz |
Tolerance of rated frequency | 48 – 63Hz |
Rated surge voltage | 4kV |
Measuring circuit | |
Terminals | L1, L2, L3, N |
Measuring input | 3x400V AC |
Measurand | line to line voltage, line to neutral voltage, 10 minutes average voltage, frequency, rate of change of frequency (RoCoF), phase shift (PShift) |
Measuring ranges | |
Line to line voltage | 0-560V AC |
Line to neutral voltage | 0-325V AC |
Frequency | 40-60Hz |
RoCoF | 100mHz/s-2Hz/s |
PShift | 1-15° |
Digital inputs | |
Terminals | I1 i ⊥, I2 i ⊥, I3 i ⊥, I4/I5 i ⊥ |
Type of contact | potential free |
Min. switching voltage/current | 24V/5mA |
Output circuit | |
Terminals | 11-12-14; 21-22-24; 31-32-34; |
Number of contacts | 3 changeover |
Contact material | AgNi |
Rated current | 5A/250V AC |
Electrical endurance | 100x103switching cycles (AC-1) |
Mechanical endurance | 15x106switching cycles |
Accuracy | |
Base accuracy (voltage) | <0,5% @ 25°C |
Temperature influence | <0,01%/°C |
Resolution | 10mV |
Base accuracy (frequency) | <0,01 Hz dla 25°C |
Temperature influence | <0,00002Hz/°C |
Resolution | 1mHz |
Isolation data | |
Rated insulation voltage | 400V |
Supply circuit/measuring circuit | protective separation |
Supply circuit/output circuit | protective separation |
Supply circuit/digital inputs | protective separation |
Output circuit/measuring circuit | protective separation |
Output circuit/digital inputs | protective separation |
Environmental conditions | |
Ambient temperature operation | -25…55°C |
Ambient temperature storage | -40…70°C |
Ambient temperature display | -15…55°C |
Relative humidity | 5…95% (non-condensing) |
Weight | 300g |
Electrical connection | |
Wire size | max. 2,5mm2 |
Stripping length | max. 8mm |
Electrical strength | max. 450V/16A (digital inputs, relay outputs) max. 750V/16A (measuring inputs) |
Torque | max. 0,5Nm |
Screw | M3, slotted recess for screw driver 0,6 x 3,5mm |
Sealing wire | dMAX = 0,8mm |
In order to ensure the proper function during power failures, an external UPS has to be used.