Snímač odpor proti směru ACT-04
  • Snímač odpor proti směru ACT-04

Fotografie slouží pouze pro informační účely. Zobrazit specifikaci produktu

please use latin characters

Výrobce: DACPOL

Snímač odpor proti směru ACT-04

Straight resistant sensor with stub pipe is used for temperature measurement in machines, pipelines and gas or liquid containers in temperature range -200°C - +600°C. Protection pipe is made from steel 1.4571, 1.7335 and Hastelloy C22, which allows to use thermometer for aggressive media measurement. Version without stub pipe also available.

 
SPECIFICATION:
Model Execution Insert type Length L
U With not changeable insert not changeable arbitrary
PS With changeable insert WP-OP-01/PS
PS/Exi Spark safe with changeable insert
PS/Exe Strengthen casing with changeable insert

SENSOR TECHNICAL PARAMETERS
Measurement resistor Version Characteristic Measurement range Accuracy class Max measurement current Connection type
1xPt100
2xPt100

normal

shockproof

wg PN-EN-60751 from -200°C
up to +600°C
B 8 mA 2 cables
A 5 mA 3, 4
cables
-50°C+150°C 1/3 B DIN 2 mA


Protection pipes
Diameter
d[mm]

Materials according to
WNr/ DIN

Materials according to
ASTM /AISI
Ø4,Ø6,Ø8,Ø9,Ø10, Ø11,Ø12,Ø15 1.4571 316 Ti
Ø10,Ø11,Ø15 1.7335 A182 Grade Fil
Ø13,7 Hastelloy C22 A576 Grade 1020
 
Stub pipe D
M20x1,5
M27x2
G 1/2"
G 3/4"
G 1”
Connection head
Type Max operation temperature Material
B +100°C Al
NA (with silicone washer) +150°C Al
 
Measurement transducer
according to order

 

Marking:

A. Execution
A
 
With not changeable insert
U
 
With changeable insert
PS
 
Spark safe with changeable insert
PS/Exi
 
Strengthen casing with changeable insert
PS/Exe
B. Resistor type
B
 
Single
1xPt100
 
Double
2xPt100
C. Accuracy class
C
 
B
B
 
A
A
 
1/3 B DIN
1/3 B DIN
D. Connection type
D
 
2 - cables
2p
 
3 - cables
3p
 
4 - cables
4p
E. Shield diameter
E
 
Ø4mm
4
 
Ø6mm
6
 
Ø8mm
8
 
Ø9mm
9
 
Ø10mm
10
 
Ø11mm
11
 
Ø12mm
12
 
Ø13.7mm
13.7
 
Ø15mm
15
F. Shield length
F
 
L
give in mm
G. Shield material
G
 
1.4571
1.4571
 
1.7335
1.7335
 
Hastelloy C22
C22
H. Stub pipe
H
 
M20x1.5
M20x1.5
 
M27x2
M27x2
 
G 1/2
G 1/2
 
G 3/4
G 3/4
 
G 1
G 1
I. Head
I
 
NH (at operation temperature up to +100°C)
N1
 
NA (at operation temperature up to +150°C)
N2
 
B
B
K. Operation temperature
K
 
T
give in mm °C
L. Measurement transducer
L
    give type and range in °C
M. Sensor type
M
 
normal 
Z
  shockproof W
 

Zašlete dotaz

Máte zájem o tento produkt? Potřebujete další informace nebo individuální ceny?

Kontaktujte nás
ZEPTEJTE SE O PRODUKT close
Děkujeme za zaslání zprávy. Odpovíme co nejdříve.
ZEPTEJTE SE O PRODUKT close
Procházet

Přidat do seznamu přání

musíš být přihlášen

Straight resistant sensor with stub pipe is used for temperature measurement in machines, pipelines and gas or liquid containers in temperature range -200°C - +600°C. Protection pipe is made from steel 1.4571, 1.7335 and Hastelloy C22, which allows to use thermometer for aggressive media measurement. Version without stub pipe also available.

 
SPECIFICATION:
Model Execution Insert type Length L
U With not changeable insert not changeable arbitrary
PS With changeable insert WP-OP-01/PS
PS/Exi Spark safe with changeable insert
PS/Exe Strengthen casing with changeable insert

SENSOR TECHNICAL PARAMETERS
Measurement resistor Version Characteristic Measurement range Accuracy class Max measurement current Connection type
1xPt100
2xPt100

normal

shockproof

wg PN-EN-60751 from -200°C
up to +600°C
B 8 mA 2 cables
A 5 mA 3, 4
cables
-50°C+150°C 1/3 B DIN 2 mA


Protection pipes
Diameter
d[mm]

Materials according to
WNr/ DIN

Materials according to
ASTM /AISI
Ø4,Ø6,Ø8,Ø9,Ø10, Ø11,Ø12,Ø15 1.4571 316 Ti
Ø10,Ø11,Ø15 1.7335 A182 Grade Fil
Ø13,7 Hastelloy C22 A576 Grade 1020
 
Stub pipe D
M20x1,5
M27x2
G 1/2"
G 3/4"
G 1”
Connection head
Type Max operation temperature Material
B +100°C Al
NA (with silicone washer) +150°C Al
 
Measurement transducer
according to order

 

Marking:

A. Execution
A
 
With not changeable insert
U
 
With changeable insert
PS
 
Spark safe with changeable insert
PS/Exi
 
Strengthen casing with changeable insert
PS/Exe
B. Resistor type
B
 
Single
1xPt100
 
Double
2xPt100
C. Accuracy class
C
 
B
B
 
A
A
 
1/3 B DIN
1/3 B DIN
D. Connection type
D
 
2 - cables
2p
 
3 - cables
3p
 
4 - cables
4p
E. Shield diameter
E
 
Ø4mm
4
 
Ø6mm
6
 
Ø8mm
8
 
Ø9mm
9
 
Ø10mm
10
 
Ø11mm
11
 
Ø12mm
12
 
Ø13.7mm
13.7
 
Ø15mm
15
F. Shield length
F
 
L
give in mm
G. Shield material
G
 
1.4571
1.4571
 
1.7335
1.7335
 
Hastelloy C22
C22
H. Stub pipe
H
 
M20x1.5
M20x1.5
 
M27x2
M27x2
 
G 1/2
G 1/2
 
G 3/4
G 3/4
 
G 1
G 1
I. Head
I
 
NH (at operation temperature up to +100°C)
N1
 
NA (at operation temperature up to +150°C)
N2
 
B
B
K. Operation temperature
K
 
T
give in mm °C
L. Measurement transducer
L
    give type and range in °C
M. Sensor type
M
 
normal 
Z
  shockproof W
 
Komentáře (0)