Musíte být přihlášen
Category
Montaż urządzeń
Modernizacja induktorów
Urządzenia indukcyjne
asd
Fotografie slouží pouze pro informační účely. Zobrazit specifikaci produktu
please use latin characters
• Continuous operating temperatures: -60 °C to +105 °C • All colours including two-coloured. • UL approval as per standard UL 758 - File no.: E101965. • Cabling for household electrical heating appliances, rotating machines, lighting. • Other nominal cross-sections: contact us. |
![]() 1 • Bare copper or tin-plated core. |
Style | 3232 | 3243 | 3171 | ||||
---|---|---|---|---|---|---|---|
105 °C -300 V | 105 °C - 300 V | 105 °C -600 V | |||||
Nominal cross-section | Avg thickness of insulation | Nominal diameter* | Avg thickness of insulation | Nominal diameter* | Avg thickness of insulation | Nominal diameter* | |
AWG | [mm2] | [mm] | [mm] | [mm] | |||
26 | 0.13 | 0.38 | 1.2 | 0.38 | 1.3 | 0.76 | 2.0 |
24 | 0.22 | 0.38 | 1.4 | 0.38 | 1.5 | 0.76 | 2.2 |
22 | 0.34 | 0.38 | 1.6 | 0.38 | 1.6 | 0.76 | 2.4 |
– | 0.5 | 0.38 | 1.7 | 0.38 | 1.8 | 0.76 | 2.5 |
20 | 0.6 | 0.38 | 1.8 | 0.38 | 1.9 | 0.76 | 2.6 |
– | 0.75 | 0.38 | 1.9 | 0.38 | 2.0 | 0.76 | 2.7 |
18 | 0.93 | 0.38 | 2.0 | 0.38 | 2.1 | 0.76 | 2.8 |
– | 1 | 0.38 | 2.1 | 0.38 | 2.2 | 0.76 | 2.9 |
16 | 1.34 | 0.38 | 2.3 | 0.38 | 2.4 | 0.76 | 3.1 |
– | 1.5 | 0.38 | 2.4 | 0.38 | 2.5 | 0.76 | 3.1 |
14 | – | – | – | – | – | 0.76 | 3.6 |
– | 2.5 | – | – | – | – | 0.76 | 3.8 |
12 | – | – | – | – | – | 0.76 | 4.1 |
– | 4 | – | – | – | – | 0.76 | 4.4 |
Conducting metal | B | BF (Ø 0.05 mm) | BF (Ø 0.05 mm) |
* The diameter is provided for information purposes as it may vary depending on the stranding of the core. Only the average thickness of insulation should be taken into account.
KEY
Conducting metals
B Tin-plated copper
B* Tin-plated copper (Ø > 0.38 mm)
C Nickel-plated copper
D Silver-plated copper
E Nickel
F Bare copper
F* Bare copper (Ø > 0.38 mm)
G Nickel-plated copper 27%
AWM I A Internal wiring, not subject to mechanical abuse
AWM I A/B Internal wiring
AWM II A/B External or Internal wiring
NS Not Specified
VNS Voltage Not Specified
Máte zájem o tento produkt? Potřebujete další informace nebo individuální ceny?
musíš být přihlášen
• Continuous operating temperatures: -60 °C to +105 °C • All colours including two-coloured. • UL approval as per standard UL 758 - File no.: E101965. • Cabling for household electrical heating appliances, rotating machines, lighting. • Other nominal cross-sections: contact us. |
![]() 1 • Bare copper or tin-plated core. |
Style | 3232 | 3243 | 3171 | ||||
---|---|---|---|---|---|---|---|
105 °C -300 V | 105 °C - 300 V | 105 °C -600 V | |||||
Nominal cross-section | Avg thickness of insulation | Nominal diameter* | Avg thickness of insulation | Nominal diameter* | Avg thickness of insulation | Nominal diameter* | |
AWG | [mm2] | [mm] | [mm] | [mm] | |||
26 | 0.13 | 0.38 | 1.2 | 0.38 | 1.3 | 0.76 | 2.0 |
24 | 0.22 | 0.38 | 1.4 | 0.38 | 1.5 | 0.76 | 2.2 |
22 | 0.34 | 0.38 | 1.6 | 0.38 | 1.6 | 0.76 | 2.4 |
– | 0.5 | 0.38 | 1.7 | 0.38 | 1.8 | 0.76 | 2.5 |
20 | 0.6 | 0.38 | 1.8 | 0.38 | 1.9 | 0.76 | 2.6 |
– | 0.75 | 0.38 | 1.9 | 0.38 | 2.0 | 0.76 | 2.7 |
18 | 0.93 | 0.38 | 2.0 | 0.38 | 2.1 | 0.76 | 2.8 |
– | 1 | 0.38 | 2.1 | 0.38 | 2.2 | 0.76 | 2.9 |
16 | 1.34 | 0.38 | 2.3 | 0.38 | 2.4 | 0.76 | 3.1 |
– | 1.5 | 0.38 | 2.4 | 0.38 | 2.5 | 0.76 | 3.1 |
14 | – | – | – | – | – | 0.76 | 3.6 |
– | 2.5 | – | – | – | – | 0.76 | 3.8 |
12 | – | – | – | – | – | 0.76 | 4.1 |
– | 4 | – | – | – | – | 0.76 | 4.4 |
Conducting metal | B | BF (Ø 0.05 mm) | BF (Ø 0.05 mm) |
* The diameter is provided for information purposes as it may vary depending on the stranding of the core. Only the average thickness of insulation should be taken into account.
KEY
Conducting metals
B Tin-plated copper
B* Tin-plated copper (Ø > 0.38 mm)
C Nickel-plated copper
D Silver-plated copper
E Nickel
F Bare copper
F* Bare copper (Ø > 0.38 mm)
G Nickel-plated copper 27%
AWM I A Internal wiring, not subject to mechanical abuse
AWM I A/B Internal wiring
AWM II A/B External or Internal wiring
NS Not Specified
VNS Voltage Not Specified
Vaše hodnocení nelze odeslat