CIP-Kabel - C1P / T - C1P / I
  • CIP-Kabel - C1P / T - C1P / I

Fotos dienen nur zu Informationszwecken.

please use latin characters

Hersteller: Flexelec

CIP-Kabel - C1P / T - C1P / I

Aplications

C1P, C1P/T and C1P/I heating cords are mainly used in the household electrical or refrigeration industries, or in machines requiring protection against freezing or temperature maintenance. To ensure that these heating cables elements enjoy a long service life, we recommend using a control device.


Characterictics
  • UL Recognized cords on request.
  • C1P: PVC insulated heating cords.
  • C1P/T: PVC insulated heating cords with tinned copper braid for mechanical protection and earthing.
  • C1P/I: PVC insulated heating cords with stainless steel braid for mechanical protection and earthing.
 
PRODUCTS INSULATION CLASS
C1P CLASS 0 (single insualated)
CLASS III (if low voltage)
C1P/T – C1P/I CLASS I (earthing)

  C1P C1P/T - C1P/
Support Fibre glass
Ø 0.7 or Ø 1.1 mm
Heating wire nickel-copper or nickel-chrome
Insultaion PVC 105°C
Diameter 2.0 to 3.0 mm 2.3 to 3.3 mm
Max. ohmic value 5000 Ω/m
Max. power 15 W/m
Max. voltage 600 V
Permissible surface temperature from - 30 °C to + 200 °C
Tolerances Resistance ± 10 %
Diameter + 0.2 /- 0.1 mm

Senden Sie eine Anfrage

Interessieren Sie sich für dieses Produkt? Benötigen Sie zusätzliche Informationen oder individuelle Preise?

Kontaktiere uns
FRAGEN SIE NACH DEM PRODUKT close
Vielen Dank für die Zusendung Ihrer Nachricht. Wir werden so schnell wie möglich antworten.
FRAGEN SIE NACH DEM PRODUKT close
Durchsuche

Zur Wunschliste hinzufügen

Sie müssen eingeloggt sein

Aplications

C1P, C1P/T and C1P/I heating cords are mainly used in the household electrical or refrigeration industries, or in machines requiring protection against freezing or temperature maintenance. To ensure that these heating cables elements enjoy a long service life, we recommend using a control device.


Characterictics
  • UL Recognized cords on request.
  • C1P: PVC insulated heating cords.
  • C1P/T: PVC insulated heating cords with tinned copper braid for mechanical protection and earthing.
  • C1P/I: PVC insulated heating cords with stainless steel braid for mechanical protection and earthing.
 
PRODUCTS INSULATION CLASS
C1P CLASS 0 (single insualated)
CLASS III (if low voltage)
C1P/T – C1P/I CLASS I (earthing)

  C1P C1P/T - C1P/
Support Fibre glass
Ø 0.7 or Ø 1.1 mm
Heating wire nickel-copper or nickel-chrome
Insultaion PVC 105°C
Diameter 2.0 to 3.0 mm 2.3 to 3.3 mm
Max. ohmic value 5000 Ω/m
Max. power 15 W/m
Max. voltage 600 V
Permissible surface temperature from - 30 °C to + 200 °C
Tolerances Resistance ± 10 %
Diameter + 0.2 /- 0.1 mm