Abschirmungsbänder von einem geflochtenen Gitter
  • Abschirmungsbänder von einem geflochtenen Gitter

Fotos dienen nur zu Informationszwecken.

please use latin characters

Hersteller: TEMAS

Abschirmungsbänder von einem geflochtenen Gitter

  • especially designed for shielding and grounding of electrical and electronic cable assemblies
  • flexible structure to conform to irregular surfaces and contours during the wrapping process
    (50% overlap bandage)
  • tin plating to allow solderability
  • useful for static discharge (esd)
  • tinned copper clad steel is standard material (best performance)
  • several other alloys and wire diameters are available
 

Available materials

  • tinned copper clad steel  (TC)
  • tinned copper  (TR)
  • stainless steel  (SL)
  • monel  (MO)
  • aluminium  (AL)

Complete the P/N with

number of wires (1 is standard)
2-letters METAL SUFFIX
wire diameter (0.11 mm is standard)


Order example

C.0127.TCtape 12.7 mm width, 1 Tinned Copper Clad Steel wire, standard wire diameter (0.11 mm)
C.501.2BR/015tape 50.1 mm width, 2 Tinned Copper wires, wire diameter 0.12 mm

P/N Width
[mm]

C.0127

12,7

C.0191

19,1

C.0254

25,4

C.0508

50,8

C.0762

76,2

C.1016

101,6

C.1524

152,4

ST.111

11.1

ST.127

12.7

Mechanical tolerances:
<20 mm +0,8 -0,8 mm
21-50 mm +1,3 -1,3 mm
51-155 mm +2,0 -2,0 mm

 

Frequency Attenuation
[dB]
  TC MO SL AL TR
1 MHz 78 70 69 73 73
10 MHz 66 64 61 63 65
100 MHz 60 60 58 58 59
1 GHz 55 56 51 56 54
10 GHz 40 42 37 44 40

NOTE:
these values are indicative only and are for 50% overlap, giving effective 4 layers of mesh

 

E-field attenuation

Taśmy ekranujące z plecionej siatki

Senden Sie eine Anfrage

Interessieren Sie sich für dieses Produkt? Benötigen Sie zusätzliche Informationen oder individuelle Preise?

Kontaktiere uns
FRAGEN SIE NACH DEM PRODUKT close
Vielen Dank für die Zusendung Ihrer Nachricht. Wir werden so schnell wie möglich antworten.
FRAGEN SIE NACH DEM PRODUKT close
Durchsuche

Zur Wunschliste hinzufügen

Sie müssen eingeloggt sein

  • especially designed for shielding and grounding of electrical and electronic cable assemblies
  • flexible structure to conform to irregular surfaces and contours during the wrapping process
    (50% overlap bandage)
  • tin plating to allow solderability
  • useful for static discharge (esd)
  • tinned copper clad steel is standard material (best performance)
  • several other alloys and wire diameters are available
 

Available materials

  • tinned copper clad steel  (TC)
  • tinned copper  (TR)
  • stainless steel  (SL)
  • monel  (MO)
  • aluminium  (AL)

Complete the P/N with

number of wires (1 is standard)
2-letters METAL SUFFIX
wire diameter (0.11 mm is standard)


Order example

C.0127.TCtape 12.7 mm width, 1 Tinned Copper Clad Steel wire, standard wire diameter (0.11 mm)
C.501.2BR/015tape 50.1 mm width, 2 Tinned Copper wires, wire diameter 0.12 mm

P/N Width
[mm]

C.0127

12,7

C.0191

19,1

C.0254

25,4

C.0508

50,8

C.0762

76,2

C.1016

101,6

C.1524

152,4

ST.111

11.1

ST.127

12.7

Mechanical tolerances:
<20 mm +0,8 -0,8 mm
21-50 mm +1,3 -1,3 mm
51-155 mm +2,0 -2,0 mm

 

Frequency Attenuation
[dB]
  TC MO SL AL TR
1 MHz 78 70 69 73 73
10 MHz 66 64 61 63 65
100 MHz 60 60 58 58 59
1 GHz 55 56 51 56 54
10 GHz 40 42 37 44 40

NOTE:
these values are indicative only and are for 50% overlap, giving effective 4 layers of mesh

 

E-field attenuation

Taśmy ekranujące z plecionej siatki

Kommentare (0)