Voltage range: | 230V/50Hz - 910V/50Hz |
Power: | 2,3kVAr - 250 kVAr |
It is possible to purchase the whole battery with regulator. For details please contact DACPOL
Standards: | IEC 831-1+2/88, EN 60831-1+2/93, VDE 560-46+47 3/95 |
Over voltage | Ucn + 10% (up to 8 hours per day) |
Ucn + 15% (up to 30 minutes per day) | |
Ucn + 20% (up to 5 minutes) | |
Ucn + 30% (do1 minutes) | |
Over current: | 1,3 * In, |
1,3 * with 10% over voltage, | |
with 15% over capacity and THD | |
capacity tolerance | -5/ + 10% |
Voltage test | (terminal - terminal) 2,15 * Ucn, AC, 2 sec |
((terminal - casing) 4800 VAC, 2 sec | |
Test current | 200*In |
Losses | 0,25 W/kVAr |
Life time: | > 100 000 hours |
IP | IP00 |
Operation temperature | -25 / D (55°C), (-40 / D for request) |
Casing temperature | 65°C |
Cooling | Natural air |
Humidity | max. 95% |
Maximum operation height: | 2000 m above sea level |
Assembly : vertical | |
Assembly: | M12 screw |
Protection | Over pressure safety device, self regenerating |
Casing: | Aluminium box |
Dielectric | polypropylene foil , metallized with zinc |
Impregnate: | Natural oil |
Electrical terminals | casing Ø 84 mm: M5 screw in |
Casing Ø |
Interessieren Sie sich für dieses Produkt? Benötigen Sie zusätzliche Informationen oder individuelle Preise?
Sie müssen eingeloggt sein
Voltage range: | 230V/50Hz - 910V/50Hz |
Power: | 2,3kVAr - 250 kVAr |
It is possible to purchase the whole battery with regulator. For details please contact DACPOL
Standards: | IEC 831-1+2/88, EN 60831-1+2/93, VDE 560-46+47 3/95 |
Over voltage | Ucn + 10% (up to 8 hours per day) |
Ucn + 15% (up to 30 minutes per day) | |
Ucn + 20% (up to 5 minutes) | |
Ucn + 30% (do1 minutes) | |
Over current: | 1,3 * In, |
1,3 * with 10% over voltage, | |
with 15% over capacity and THD | |
capacity tolerance | -5/ + 10% |
Voltage test | (terminal - terminal) 2,15 * Ucn, AC, 2 sec |
((terminal - casing) 4800 VAC, 2 sec | |
Test current | 200*In |
Losses | 0,25 W/kVAr |
Life time: | > 100 000 hours |
IP | IP00 |
Operation temperature | -25 / D (55°C), (-40 / D for request) |
Casing temperature | 65°C |
Cooling | Natural air |
Humidity | max. 95% |
Maximum operation height: | 2000 m above sea level |
Assembly : vertical | |
Assembly: | M12 screw |
Protection | Over pressure safety device, self regenerating |
Casing: | Aluminium box |
Dielectric | polypropylene foil , metallized with zinc |
Impregnate: | Natural oil |
Electrical terminals | casing Ø 84 mm: M5 screw in |
Casing Ø |