Sie müssen eingeloggt sein
-
zurückX
-
Komponenten
-
-
Category
-
Halbleiter
- Dioden
- Thyristoren
-
Elektroisolierte Module
- Elektroisolierte Module | VISHAY (IR)
- Elektroisolierte Module | INFINEON (EUPEC)
- Elektroisolierte Module | Semikron
- Elektroisolierte Module | POWEREX
- Elektroisolierte Module IXYS
- Elektroisolierte Module | POSEICO
- Elektroisolierte Module ABB
- Elektroisolierte Module | TECHSEM
- Gehen Sie zur Unterkategorie
- Brückengleichrichter
-
Transistoren
- Transistoren | GeneSiC
- SiC-MOSFET-Module | Mitsubishi
- SiC-MOSFET-Module | STARPOWER
- ABB SiC-MOSFET-Module
- IGBT-Module | MITSUBISHI
- Transistormodule | MITSUBISHI
- MOSFET-Module von MITSUBISHI
- Transistormodule | ABB
- IGBT-Module | POWEREX
- IGBT-Module | INFINEON (EUPEC)
- Halbleiterkomponente aus Siziliumkarbid
- Gehen Sie zur Unterkategorie
- Treiber
- Leistungsblöcke
- Gehen Sie zur Unterkategorie
-
Strom- und Spannungswandler von LEM
-
Stromwandler von LEM
- Stromwandler mit geschlossener Rückkopplungsschleife (C / L)
- Stromwandler mit offener Rückkopplungsschleife (O / L)
- Stromwandler mit unipolarer Spannung
- Wandler in der Eta-Technologie
- Hochgenaue Stromwandler der Serie LF xx10
- Stromwandler der Serie LH
- HOYS und HOYL - zur direkten Montage auf einer Leiterschiene
- Stromwandler in der SMD-Technologie der Serien GO-SME und GO-SMS
- AUTOMOBIL-Stromwandler
- Gehen Sie zur Unterkategorie
- Spannungswandler | LEM
- Präzisionsstromwandler | LEM
- Gehen Sie zur Unterkategorie
-
Stromwandler von LEM
-
Passive Elemente (Kondensatoren, Widerstände, Sicherungen, Filter)
- Widerstände
-
Sicherungen
- Miniatursicherungen für elektronische Schaltungen der Serien ABC und AGC
- Schnelle Röhrensicherungen
- Zeitverzögerungssicherungen mit GL / GG- und AM-Eigenschaften
- Ultraschnelle Sicherungseinsätze
- Britische und amerikanische schnelle Sicherungen
- Schnelle europäische Sicherungen
- Traktionssicherungen
- Hochspannungs-Sicherungseinsätze
- Gehen Sie zur Unterkategorie
-
Kondensatoren
- Kondensatoren für Motoren
- Elektrolytkondensator
- Island Filmkondensatoren
- Leistungskondensatoren
- Kondensatoren für Gleichstromkreise
- Kondensatoren zur Leistungskompensation
- Hochspannungskondensatoren
- Induktionsheizkondensatoren
- Impulskondensatoren
- DC LINK-Kondensatoren
- Kondensatoren für AC / DC-Schaltungen
- Gehen Sie zur Unterkategorie
- Entstörungsfilter
- Superkondensatoren
-
Überspannungsschutz
- Überspannungsableiter für HF-Anwendungen
- Überspannungsableiter für Bildverarbeitungssysteme
- Überspannungsableiter für Stromleitungen
- Überspannungsableiter für LED
- Überspannungsableiter für die Photovoltaik
- Überspannungsableiter für Wägesysteme
- Überspannungsableiter für den Feldbus
- Gehen Sie zur Unterkategorie
- Gehen Sie zur Unterkategorie
-
Relais und Schütze
- Theorie der Relais und Schütze
- Dreiphasen-Halbleiterrelais AC
- Halbleiterrelais DC
- Regler, Steuerungen und Zubehör
- Sanftstarter und Schaltschütze
- Elektromechanische Relais
- Schütze
- Drehschalter
-
Einphasen-Halbleiterrelais AC
- Einphasen-Wechselstrom-Halbleiterrelais, Serie 1 | D2425 | D2450
- Einphasige AC-Halbleiterrelais der Serien CWA und CWD
- Einphasen-Wechselstrom-Halbleiterrelais der Serien CMRA und CMRD
- Einphasen-Wechselstrom-Halbleiterrelais, PS-Serie
- Doppel- und Vierfach-Wechselstrom-Halbleiterrelais, Serie D24 D, TD24 Q, H12D48 D.
- 1-phasige Festkörperrelais, gn-Serie
- Einphasige Wechselstrom-Halbleiterrelais, Serie ckr
- Einphasen-Wechselstromrelais der ERDA- UND ERAA-SERIE für die DIN-Schiene
- Einphasige Wechselstromrelais für 150A Strom
- Doppelte Halbleiterrelais mit integriertem Kühlkörper für eine DIN-Schiene
- Gehen Sie zur Unterkategorie
- Einphasen-Halbleiterrelais AC für Leiterplatten
- Interface-Relais
- Gehen Sie zur Unterkategorie
- Induktive Komponente
- Radiatoren, Varistoren, Thermoschütze
- Ventilatoren
- Klimaanlagen, Ausrüstung für Schaltschränke, Industriekühler
-
Batterien, Ladegeräte, Pufferstromversorgungen und Wechselrichter
- Batterien, Ladegeräte - theoretische Beschreibung
- Lithium-Ionen-Batterien. Kundenspezifische Batterien. Batteriemanagementsystem (BMS)
- Batterien
- Ladegeräte und Zubehör
- USV-Notstromversorgung und Pufferstromversorgung
- Konverter und Zubehör für die Photovoltaik
- Energiespeicher
- Brennstoffzellen
- Lithium-Ionen-Batterien
- Gehen Sie zur Unterkategorie
-
Automation
- Futaba Drone Parts
- Grenzschalter, Microschalter
- Sensoren, Wandler
-
Pyrometer
- Infrarot-Temperatursensor, kabellos, wasserdicht, IR-TE-Serie
- Infrarot-Temperatursensor, kabellos, IR-TA-Serie
- Infrarot-Temperatursensor, kabellos, IR-H-Serie
- Ein schnelles stationäres Pyrometer in einem sehr kleinen IR-BA-Gehäuse
- Lichtleiter-Temperatursensoren, IR-FA-Serie
- Das stationäre Pyrometer der IR-BZ-Serie
- Gehen Sie zur Unterkategorie
- Zähler, Zeitrelais, Einbaumessgeräte
- Industrielle Schutzausrüstung
- Licht- und Signalentechnik
- Infrarot-Kamera
- LED-Anzeigen
- Taster, Schalter und Zubehör
-
Datenerfassung und Datenlogger
- Temperaturschreiber mit Display und Textdruck AL3000
- Digitale Temperaturschreiber mit LCD Display KR 2000-Serie
- Sicherheitstemperaturwächter KR 5000
- Temperatur / Feuchtigkeit Hand-Meter mit Datenlogger HN-CH-Serie
- Messdatenerfassung und Datenlogger Zubehör
- Kompakter Bildschirmschreiber 71VR1
- Sicherheitstemperaturwächter KR 3000-Serie
- PC-Datenerfassung R1M-Serie
- PC-Datenerfassung R2M-Serie
- PC-Datenerfassung, 12 universelle isolierte Eingänge, Typ RZMS-U9
- PC-Datenerfassung, 12 universelle isolierte Eingänge, USB, RZUS-Serie
- Gehen Sie zur Unterkategorie
- Gehen Sie zur Unterkategorie
-
Adern, Litzen, Schutzhüllen, Flexible Verbingungen
- Drähte
- Litzen
-
Kabel für spezielle Anwendungen
- Verlängerungskabel und Kompensations
- Kabel für Thermoelemente
- Die Verbindungsdrähte zu czyjnków PT
- Mehradrige Kabel Temp. -60 ° C bis + 1400 ° C
- SILICOUL Mittelspannungskabeln
- Zündkabel
- Heizleitungen
- Einadriges Temp. -60 ° C bis + 450 ° C
- Zugbegleiter
- Heizleitungen im Ex
- Gehen Sie zur Unterkategorie
- Schläuche
-
Geflochtene Kabel
- Zöpfe flach
- Zöpfen Runde
- Sehr flexible Geflecht - flach
- Sehr flexible Geflecht - Rund
- Kupfergeflecht zylindrischen
- Kupfergeflechtschirm und zylindrischer
- Flexible Massebänder
- Geflechte zylindrischen verzinkt und Edelstahl
- PVC-isolierte Kupferlitzen - Temperatur 85 ° C
- Flach geflochtene Aluminium
- Connection Kit - Zöpfe und Röhren
- Gehen Sie zur Unterkategorie
- Leitungen und Sonstiges für Traktion
- Crimpverbinder
- Flexible isolierte Kupferschienen
- Mehrschichte flexible Kupferschienen
- Kabelrohre, Kabelkanäle und Kabelführung
- Kabelschutzschlauchsysteme
- Gehen Sie zur Unterkategorie
- Alle Kategorien
-
Halbleiter
-
-
- Lieferanten
-
Applications
- AC- und DC-Antriebe (Wechselrichter)
- Ausrüstung für Verteilungs-, Steuerungs- und Telekommunikationsschränke
- Bergbau, Metallurgie und Gründung
- CNC-Werkzeugmaschinen
- Energy bank
- HLK-Automatisierung
- Induktionsheizung
- Industrielle Automatisierung
- Industrielle Automatisierung
- Industrielle Schutzvorrichtungen
- Komponenten für explosionsgefährdete Bereiche (EX)
- Maschinen zum Tiefziehen von Kunststoffen
- Maschinen zum Trocknen und Verarbeiten von Holz
- Motoren und Transformatoren
- Schweißmaschinen und Schweißmaschinen
- Straßenbahn- und Bahntraktion
- Temperaturmessung und -regelung
- Temperaturmessung und -regelung
- USV- und Gleichrichtersysteme
-
Installation
-
-
Montaż urządzeń
- Schaltschränkebau
- Design und Montage von Schränken
- Installation von Stromversorgungssystemen
- Komponenten
- Maschinen, die auf Bestellung gebaut werden
- F&E-Forschungs- und Entwicklungsarbeiten
-
Produktionsprozessen Messungsanlagen
- Dioden und Thyristoren Messungsanlagen
- Schaltungen Messungsanlagen
- Varistor- und Überspannungsableiter-Tester
- Messungsanlagen für Kfz-Sicherungen
- Qr Sperrverzögerungsladung Messungsanlagen
- FD-Serie Schaltungen Rotorentester
- Audit-Messungsanlagen der Fehlerstromschutzschalter
- Tester für Kalibrierung der Relais
- Anlage für Video Qualitätskontrollsysteme
- Hochstrom-Thyristorschalter
- Maschenbruch-Tester
- Gehen Sie zur Unterkategorie
- Alle Kategorien
-
-
-
Inductors
-
-
Modernizacja induktorów
- Reparatur gebrauchter Induktivitäten
- Modernisierung von Induktoren
-
Produktion neuer Induktoren
- Härten von Kurbelwellen
- Aushärten der Bandsägezähne
- Erwärmung der Elemente vor dem Verkleben
- Härtung von Laufbahnen von Radnabenlagern für Kraftfahrzeuge
- Härtung der Antriebsgetriebekomponenten
- Härten von Stufenwellen
- Erwärmung in Kontraktionsfugen
- Scan-Härtung
- Weichlöten
- Knüppelheizungen
- Gehen Sie zur Unterkategorie
- Wissensbasis
- Alle Kategorien
-
-
-
Induktionsgeräte
-
-
Urządzenia indukcyjne
-
Generatoren für Induktionserwärmung
-
Ambrell Induktionsheizgeneratoren
- Generatoren: Leistung 500 W, Frequenz 150-400 kHz
- Generatoren: Leistung 1.2 - 2.4 kW, Frequenz 150 - 400 kHz
- Generatoren: Leistung 4.2 - 10 kW, Frequenz 150 - 400 kHz
- Generatoren: Leistung 10 - 15 kW, Frequenz 50 - 150 kHz
- Generatoren: Leistung 30-45 kW, Frequenz 50-150 kHz
- Generatoren: Leistung 65-135 kW, Frequenz 50-150 kHz
- Generatoren: Leistung 180-270 kW, Frequenz 50-150 kHz
- Generatoren: Leistung 20-35-50 kW, Frequenz 15-45 kHz
- Generatoren: Leistung 75-150 kW, Frequenz 15-45 kHz
- Generatoren: Leistung 200-500 kW, Frequenz 15-45 kHz
- Generatoren: Leistung 20-50 kW, Frequenz 5-15 kHz
- Gehen Sie zur Unterkategorie
- Denki Kogyo Induktionsheizungsgeneratoren
-
JKZ Induktionsheizungsgeneratoren
- Generatoren der CX-Serie, Frequenz: 50-120 kHz, Leistung: 5-25 kW
- Generatoren der SWS-Serie, Frequenz: 15-30 kHz, Leistung: 25-260 kW
- Generatoren (Öfen) zum Formen und Schmieden der MFS-Serie, Frequenz: 0,5-10 kHz, Leistung: 80-500 kW
- MFS-Schmelzöfen, Frequenz: 0,5-10 kHz, Leistung: 70-200 kW
- Generatoren der UHT-Serie, Frequenz: 200-400 kHz, Leistung: 10-160 kW
- Gehen Sie zur Unterkategorie
- Lampengeneratoren für Induktionsheizung
- Himmelwerk Induktionsheizungsgeneratoren
- Gehen Sie zur Unterkategorie
-
Ambrell Induktionsheizgeneratoren
- Reparaturen und Modernisierung
- Peripheriegeräte
-
Applikationen
- Medizinische Anwendungen
- Automobilindustrie Applikationen
- Löten
- Hartlöten
- Hartlöten von Aluminium
- Löten von magnetischen Edelstahlwerkzeugen
- Präzisionslöten
- Löten unter Atmosphäre
- Löten von Kühlkörperkappen aus Messing und Stahl
- Löten von Sintercarbiden
- Löten der Kupferspitze und des Drahtes
- Gehen Sie zur Unterkategorie
- Wissensbasis
- Alle Kategorien
-
Generatoren für Induktionserwärmung
-
-
-
Service
-
-
asd
- Wartung von Brauchwasserkühlern und Klimaanlagen
- Reparaturen und Modernisierung von Maschinen
- Reparatur der Leistungselektronik und elektonischen und automatischen Vorrichtungen
- Hochspannungsnetzteile für Elektrofilter
- Industriedrucker und Etikettierer
- Certyfikaty / uprawnienia
- Alle Kategorien
-
-
- Kontakt
- Zobacz wszystkie kategorie
Fotos dienen nur zu Informationszwecken.
please use latin characters
Adaptive 4-stage charge characteristic: bulk – absorption – float – storage
The Phoenix charger features a microprocessor controlled ‘adaptive’ battery management system that can be preset to suit different types of batteries. The ‘adaptive’ feature will automatically optimise the process relative to the way the battery is being used.
The right amount of charge: variable absorption time
When only shallow discharges occur (a yacht connected toshore power for example) the absorption time is kept short in order to prevent overcharging of the battery. After a deep discharge the absorption time is automatically increased to make sure that the batteryis completely recharged.
Preventing damage due to excessive gassing: the BatterySafe mode (see fig. 2 below)
If, in order to quickly charge a battery, a high chargecurrent in combination with a high absorption voltage has been chosen, the Phoenix charger will prevent damage due to excessive gassing by automatically limiting the rate of voltage increase once the gassing voltage has been reached (see the charge curve between 14,4 V and 15,0 V in fig. 2 below).
Less maintenance and aging when the battery is not in use: the Storage mode (see fig. 1 [&] 2 below)
The storage mode kicks in whenever the battery has not been subjected to discharge during 24 hours. In the storage mode float voltage is reduced to 2,2 V/cell (13,2 V for 12 V battery) to minimise gassing and corrosion of the positive plates. Once a week the voltage is raised back to the absorption level to ‘equalize’ the battery. This feature prevents stratification of the electrolyte and sulphation, a major cause of early battery failure.
Phoenix charger 12V 30A |
Phoenix charger 24V 25A |
To increase battery life: temperature compensation
Every Phoenix charger comes with a battery temperaturesensor. When connected, charge voltage will automatically decrease with increasing battery temperature. This feature is especially recommended for sealed batteries and/or when important fluctuations of battery temperature are expected.
Battery voltage sense
In order to compensate for voltage loss due to cable resistance, Phoenix chargers are provided with a voltage sense facility so that the battery always receives the correct charge voltage.
Universal 90-265V AC input voltage range and also suitable for DC supply (AC-DC and DC-DC operation)
The chargers will accept a 90-400V DC supply.
Computer interface
Every Phoenix Charger is ready to communicate with a computer through its RS-485 data port. Together with our VEConfiguresoftware, which can be downloaded free of charge fromour website www.victronenergy.com and the data link MK1b (see accessories), all parameters of the chargers can be customised.
Learn more about batteries and battery charging
To learn more about batteries and charging batteries, please refer to our book ‘Energy Unlimited’ (available free of charge from Victron Energy and downloadable from www.victronenergy.com). For more information about adaptive charging please look under Technical Information on our website.
Charge curves: up to the gassing voltage (wykres.1), and exceeding the gassing voltage (wykres.2)
Phoenix Charger | 12/30 | 12/50 | 24/16 | 24/25 |
---|---|---|---|---|
Input voltage range (V AC) | 90-265 | |||
Input voltage range (V DC) | 90-400 | |||
Frequency (Hz) | 45-65 | |||
Power factor | 1 | |||
Charge voltage 'absorption' (V DC) | 14,4 | 14,4 | 28,8 | 28,8 |
Charge voltage 'float' (V DC) | 13,8 | 13,8 | 27,6 | 27,6 |
Storage mode (V DC) | 13,2 | 13,2 | 26,4 | 26,4 |
Charge current house batt. (A) (2) | 30 | 50 | 16 | 25 |
Charge current starter batt. (A) | 4 | 4 | 4 | 4 |
Charge characteristic | 4 stage adaptive | |||
Battery capacity (Ah) | 100-400 | 200-800 | 100-200 | 100-400 |
Temperature sensor | V | V | V | V |
Can be used as power supply | V | V | V | V |
Forced cooling | V | V | V | V |
Protection (1) | a,b,c,d | |||
Operating temp. range | -20 to 60°C (0 - 140°F) | |||
Humidity (non condensing) | max 95% | |||
ENCLOSURE | ||||
Material [&] Colour | aluminium (blue RAL 5012) | |||
Battery-connection | M6 studs | |||
AC-connection | screw-clamp 4 mm² (AWG 11) | |||
Protection category | IP 21 | |||
Weight kg (lbs) | 3,8 (8) | |||
Dimensions (hxwxd in mm and inches) | 350x200x108 mm (13.8x7.9x4.3 inch) | |||
STANDARDS | ||||
Safety | EN 60335-1, EN 60335-2-29 | |||
Emission Immunity | EN 55014-1, EN 61000-3-2, | |||
Automotive Directive | EN 55014-2, EN 61000-3-3 | |||
Vibration | IEC68-2-6:10-150Hz/1.0G | |||
1) Protection 2) Up to 40 °C (100 °F) ambient a)Output short circuit b)Battery reverse polarity detection c) Battery voltage too high d) Temperature too high |
An excessively high or low battery voltage is indicated by an audible and visual alarm, and potential free contacts.
The PCC panel provides remote control and monitoring of the charge process with LED indication of the charger status. In addition, the remote panel also offers output current adjustment that can be used to limit the output current and thus the power drawn from the AC supply. This is particularly useful when operating the charger from limited shore power or small gensets. The panel can also be used to change the battery charging parameters.
The brightness of the LED’s is automatically reduced during night time.
Connection to the charger is with a standard UTP – cable.
The BMV 600S Battery Monitor features an advanced microprocessor control system combined with high resolution measuring systems for battery voltage and charge/discharge current. Besides this, the software includes complex calculation algorithms, like Peukert’s formula, to exactly determine the state of charge of the battery. The BMV 600S selectively displays battery voltage, current, consumed Ah or time to go
Senden Sie eine Anfrage
Interessieren Sie sich für dieses Produkt? Benötigen Sie zusätzliche Informationen oder individuelle Preise?
Kontaktiere uns
Sie müssen eingeloggt sein
Adaptive 4-stage charge characteristic: bulk – absorption – float – storage
The Phoenix charger features a microprocessor controlled ‘adaptive’ battery management system that can be preset to suit different types of batteries. The ‘adaptive’ feature will automatically optimise the process relative to the way the battery is being used.
The right amount of charge: variable absorption time
When only shallow discharges occur (a yacht connected toshore power for example) the absorption time is kept short in order to prevent overcharging of the battery. After a deep discharge the absorption time is automatically increased to make sure that the batteryis completely recharged.
Preventing damage due to excessive gassing: the BatterySafe mode (see fig. 2 below)
If, in order to quickly charge a battery, a high chargecurrent in combination with a high absorption voltage has been chosen, the Phoenix charger will prevent damage due to excessive gassing by automatically limiting the rate of voltage increase once the gassing voltage has been reached (see the charge curve between 14,4 V and 15,0 V in fig. 2 below).
Less maintenance and aging when the battery is not in use: the Storage mode (see fig. 1 [&] 2 below)
The storage mode kicks in whenever the battery has not been subjected to discharge during 24 hours. In the storage mode float voltage is reduced to 2,2 V/cell (13,2 V for 12 V battery) to minimise gassing and corrosion of the positive plates. Once a week the voltage is raised back to the absorption level to ‘equalize’ the battery. This feature prevents stratification of the electrolyte and sulphation, a major cause of early battery failure.
Phoenix charger 12V 30A |
Phoenix charger 24V 25A |
To increase battery life: temperature compensation
Every Phoenix charger comes with a battery temperaturesensor. When connected, charge voltage will automatically decrease with increasing battery temperature. This feature is especially recommended for sealed batteries and/or when important fluctuations of battery temperature are expected.
Battery voltage sense
In order to compensate for voltage loss due to cable resistance, Phoenix chargers are provided with a voltage sense facility so that the battery always receives the correct charge voltage.
Universal 90-265V AC input voltage range and also suitable for DC supply (AC-DC and DC-DC operation)
The chargers will accept a 90-400V DC supply.
Computer interface
Every Phoenix Charger is ready to communicate with a computer through its RS-485 data port. Together with our VEConfiguresoftware, which can be downloaded free of charge fromour website www.victronenergy.com and the data link MK1b (see accessories), all parameters of the chargers can be customised.
Learn more about batteries and battery charging
To learn more about batteries and charging batteries, please refer to our book ‘Energy Unlimited’ (available free of charge from Victron Energy and downloadable from www.victronenergy.com). For more information about adaptive charging please look under Technical Information on our website.
Charge curves: up to the gassing voltage (wykres.1), and exceeding the gassing voltage (wykres.2)
Phoenix Charger | 12/30 | 12/50 | 24/16 | 24/25 |
---|---|---|---|---|
Input voltage range (V AC) | 90-265 | |||
Input voltage range (V DC) | 90-400 | |||
Frequency (Hz) | 45-65 | |||
Power factor | 1 | |||
Charge voltage 'absorption' (V DC) | 14,4 | 14,4 | 28,8 | 28,8 |
Charge voltage 'float' (V DC) | 13,8 | 13,8 | 27,6 | 27,6 |
Storage mode (V DC) | 13,2 | 13,2 | 26,4 | 26,4 |
Charge current house batt. (A) (2) | 30 | 50 | 16 | 25 |
Charge current starter batt. (A) | 4 | 4 | 4 | 4 |
Charge characteristic | 4 stage adaptive | |||
Battery capacity (Ah) | 100-400 | 200-800 | 100-200 | 100-400 |
Temperature sensor | V | V | V | V |
Can be used as power supply | V | V | V | V |
Forced cooling | V | V | V | V |
Protection (1) | a,b,c,d | |||
Operating temp. range | -20 to 60°C (0 - 140°F) | |||
Humidity (non condensing) | max 95% | |||
ENCLOSURE | ||||
Material [&] Colour | aluminium (blue RAL 5012) | |||
Battery-connection | M6 studs | |||
AC-connection | screw-clamp 4 mm² (AWG 11) | |||
Protection category | IP 21 | |||
Weight kg (lbs) | 3,8 (8) | |||
Dimensions (hxwxd in mm and inches) | 350x200x108 mm (13.8x7.9x4.3 inch) | |||
STANDARDS | ||||
Safety | EN 60335-1, EN 60335-2-29 | |||
Emission Immunity | EN 55014-1, EN 61000-3-2, | |||
Automotive Directive | EN 55014-2, EN 61000-3-3 | |||
Vibration | IEC68-2-6:10-150Hz/1.0G | |||
1) Protection 2) Up to 40 °C (100 °F) ambient a)Output short circuit b)Battery reverse polarity detection c) Battery voltage too high d) Temperature too high |
An excessively high or low battery voltage is indicated by an audible and visual alarm, and potential free contacts.
The PCC panel provides remote control and monitoring of the charge process with LED indication of the charger status. In addition, the remote panel also offers output current adjustment that can be used to limit the output current and thus the power drawn from the AC supply. This is particularly useful when operating the charger from limited shore power or small gensets. The panel can also be used to change the battery charging parameters.
The brightness of the LED’s is automatically reduced during night time.
Connection to the charger is with a standard UTP – cable.
The BMV 600S Battery Monitor features an advanced microprocessor control system combined with high resolution measuring systems for battery voltage and charge/discharge current. Besides this, the software includes complex calculation algorithms, like Peukert’s formula, to exactly determine the state of charge of the battery. The BMV 600S selectively displays battery voltage, current, consumed Ah or time to go
Your review appreciation cannot be sent
Report comment
Report sent
Your report cannot be sent
Eigenen Kommentar verfassen
Review sent
Your review cannot be sent