Rogls-3PH-Serie-Spule
  • Rogls-3PH-Serie-Spule

Fotos dienen nur zu Informationszwecken.

please use latin characters

Hersteller: PEM

Rogls-3PH-Serie-Spule

The RCTrms-3ph is a 3-Channel AC current transducer for permanent installation. Simple to install and easy to retrofit it combines the benefits of a thin, flexible, clip-around Rogowski (sense) coil with a signal conditioner providing accurate, true rms measurement, of AC current. The RCTrms-3ph has an industry standard 4-20mA or 0-5V output making it ideal for process control, status alarming or system monitoring purposes. Typically the RCTrms is used with SCADA systems, PLCs, data loggers

Features:

  • Easy to retrofit
  • Simple to install in applications where space is limited
  • The size of the Rogowski coil can be specified independently of the primary current
  • Does not suffer from magnetic saturation
  • Ideal for process control, status alarming or system monitoring in a wide variety of applications, from arc furnaces to power distribution.
  • CE marked
  • Complies with EMC EN 61326-1 2006
  • Complies with IEC61010-1:2001 

Specifications:

  • Traceable calibration
    • Every unit is supplied with a traceable calibration certificate
    • No magnetic materials means excellent linearity<0.1% reading
  • Fully isolated measurement
    • Isolated power supply 2kVdc
    • Coil rated at 2kVpeak (withstand test is 4kVrms /50Hz/ 60 sec)
  • Small DIN rail (or panel mount) enclosure – UL94 V-0 rated
 

Options:

  • Isolated BNC-BNC cable split option
    - Between coil and electronics to enable ease of installation e.g. threading through existing conduit. Standard cable permanently fixed.
Rated current [Arms] 100, 250, 500, 800, 1000, 1600, 2000, 2500, 3000, 4000, 5000, 8000,10000,16000, 20000, 25000, 40000, 50000
Rated output (Full scale FS)

4 ÷ 20mAdc or 0 ÷ 5Vdc

Output limit 150% FS (28mA or 7.5Vdc)
Supply voltage (Wide input) 12Vdc (-10%) to 24Vdc (+20%)
Input power 2.1W (at rated output)
Operating temperature range -5°C do +65°C (Integrator)
-20°C do +80°C (Coil and cable)
Bandwidth (-3dB) 2Hz do 100kHz
Max. Response time (10 to 90%) (10 do 90%) 1000ms
Accuracy (typ.) ±1.0% of reading (0-5V)
±1.5% of reading (4-20mA)
(10% to 150% FS, 25°C)
Output load <300Ω for 4-20mA output
>1kΩ for 0-5V output
Coil Length 300mm, 500mm or 700mm (Custom lengths available)
Cable Length 1m or 2.5m
(coil to electronics)
1m or 2,5m (Custom lengths available)

Connection
RCTrms-3ph series connection
Catalogue number
 
RCTrms-3ph series catalogu number
Output
420 – 4-20mAdc
005 – 0-5Vdc
Current range [A]:
250, 500, 800, 1000, 1600, 2000, 2500, 3000, 4000, 5000, 8000, 10000, 16000, 20000, 25000, 30000, 40000, 50000
Cable Length [m]:
1
2,5
.... Custom lengths available
Coil Lengthi [mm]:
300
500
700
.... Custom lengths available
Options:
Isolated BNC-BNC cable split option
Dimensions [mm]

RCTrms-3ph series dimensions

Senden Sie eine Anfrage

Interessieren Sie sich für dieses Produkt? Benötigen Sie zusätzliche Informationen oder individuelle Preise?

Kontaktiere uns
FRAGEN SIE NACH DEM PRODUKT close
Vielen Dank für die Zusendung Ihrer Nachricht. Wir werden so schnell wie möglich antworten.
FRAGEN SIE NACH DEM PRODUKT close
Durchsuche

Zur Wunschliste hinzufügen

Sie müssen eingeloggt sein

The RCTrms-3ph is a 3-Channel AC current transducer for permanent installation. Simple to install and easy to retrofit it combines the benefits of a thin, flexible, clip-around Rogowski (sense) coil with a signal conditioner providing accurate, true rms measurement, of AC current. The RCTrms-3ph has an industry standard 4-20mA or 0-5V output making it ideal for process control, status alarming or system monitoring purposes. Typically the RCTrms is used with SCADA systems, PLCs, data loggers

Features:

  • Easy to retrofit
  • Simple to install in applications where space is limited
  • The size of the Rogowski coil can be specified independently of the primary current
  • Does not suffer from magnetic saturation
  • Ideal for process control, status alarming or system monitoring in a wide variety of applications, from arc furnaces to power distribution.
  • CE marked
  • Complies with EMC EN 61326-1 2006
  • Complies with IEC61010-1:2001 

Specifications:

  • Traceable calibration
    • Every unit is supplied with a traceable calibration certificate
    • No magnetic materials means excellent linearity<0.1% reading
  • Fully isolated measurement
    • Isolated power supply 2kVdc
    • Coil rated at 2kVpeak (withstand test is 4kVrms /50Hz/ 60 sec)
  • Small DIN rail (or panel mount) enclosure – UL94 V-0 rated
 

Options:

  • Isolated BNC-BNC cable split option
    - Between coil and electronics to enable ease of installation e.g. threading through existing conduit. Standard cable permanently fixed.
Rated current [Arms] 100, 250, 500, 800, 1000, 1600, 2000, 2500, 3000, 4000, 5000, 8000,10000,16000, 20000, 25000, 40000, 50000
Rated output (Full scale FS)

4 ÷ 20mAdc or 0 ÷ 5Vdc

Output limit 150% FS (28mA or 7.5Vdc)
Supply voltage (Wide input) 12Vdc (-10%) to 24Vdc (+20%)
Input power 2.1W (at rated output)
Operating temperature range -5°C do +65°C (Integrator)
-20°C do +80°C (Coil and cable)
Bandwidth (-3dB) 2Hz do 100kHz
Max. Response time (10 to 90%) (10 do 90%) 1000ms
Accuracy (typ.) ±1.0% of reading (0-5V)
±1.5% of reading (4-20mA)
(10% to 150% FS, 25°C)
Output load <300Ω for 4-20mA output
>1kΩ for 0-5V output
Coil Length 300mm, 500mm or 700mm (Custom lengths available)
Cable Length 1m or 2.5m
(coil to electronics)
1m or 2,5m (Custom lengths available)

Connection
RCTrms-3ph series connection
Catalogue number
 
RCTrms-3ph series catalogu number
Output
420 – 4-20mAdc
005 – 0-5Vdc
Current range [A]:
250, 500, 800, 1000, 1600, 2000, 2500, 3000, 4000, 5000, 8000, 10000, 16000, 20000, 25000, 30000, 40000, 50000
Cable Length [m]:
1
2,5
.... Custom lengths available
Coil Lengthi [mm]:
300
500
700
.... Custom lengths available
Options:
Isolated BNC-BNC cable split option
Dimensions [mm]

RCTrms-3ph series dimensions

Kommentare (0)