Sie müssen eingeloggt sein
Category
Montaż urządzeń
Modernizacja induktorów
Urządzenia indukcyjne
asd
Fotos dienen nur zu Informationszwecken.
please use latin characters
Application:
Especially recommended in areas where it has meaning of fast shrinking and space savings.
The low shrink temperature reduces installation time and risk of damaging components sensitive to temperatue.
Technical data
Tube | Dimensions [mm] | Standard length of the spool [m] | ||
---|---|---|---|---|
type | D | d | s | |
RUC 1,4 / 0,6 |
1,4 | 0,6 | 0,20 | 200 |
RUC 1,9 / 0,8 |
1,9 | 0,8 | 0,20 | 100 |
RUC 3 / 1,2 |
3,0 | 1,2 | 0,25 | 100 |
RUC 3,5 / 1,6 |
3,5 | 1,8 | 0,25 | 100 |
RUC 5,5 / 2,4 |
5,5 | 2,4 | 0,25 | 100 |
RUC 6,5 / 3,2 |
6,5 | 3,2 | 0,28 | 100 |
RUC 10,5 / 4,8 |
10,5 | 4,8 | 0,28 | 100 |
RUC 13,5 / 6,4 |
13,5 | 6,4 | 0,28 | 50 |
D - minimum internal diamtere before recovery
d - maximum internal diamtere after recovery
s - wall thickness after entire recovery
Properties | Test method | Tubes RUC |
---|---|---|
Operating temperature: | IEC216 | -55°C to +125°C |
Tensile strength | ASTM D 2671 | > 14 MPa |
Elongation at rupture | ASTM D 2671 | > 400% |
Length change after shrinking | UL224 | 0 ±5% |
Elongation at rupture after heat ageing | 158 °C, 168h | > 300% |
Inflammability test | VW-1 | positive |
Dielectric resistance | 1EC 243 | > 20 kV/mm |
Volume resistivity | IEC93 | >10" O./cm |
Infuence on copper | ASTM D 2671 | doesn't corrode |
Interessieren Sie sich für dieses Produkt? Benötigen Sie zusätzliche Informationen oder individuelle Preise?
Sie müssen eingeloggt sein
Application:
Especially recommended in areas where it has meaning of fast shrinking and space savings.
The low shrink temperature reduces installation time and risk of damaging components sensitive to temperatue.
Technical data
Tube | Dimensions [mm] | Standard length of the spool [m] | ||
---|---|---|---|---|
type | D | d | s | |
RUC 1,4 / 0,6 |
1,4 | 0,6 | 0,20 | 200 |
RUC 1,9 / 0,8 |
1,9 | 0,8 | 0,20 | 100 |
RUC 3 / 1,2 |
3,0 | 1,2 | 0,25 | 100 |
RUC 3,5 / 1,6 |
3,5 | 1,8 | 0,25 | 100 |
RUC 5,5 / 2,4 |
5,5 | 2,4 | 0,25 | 100 |
RUC 6,5 / 3,2 |
6,5 | 3,2 | 0,28 | 100 |
RUC 10,5 / 4,8 |
10,5 | 4,8 | 0,28 | 100 |
RUC 13,5 / 6,4 |
13,5 | 6,4 | 0,28 | 50 |
D - minimum internal diamtere before recovery
d - maximum internal diamtere after recovery
s - wall thickness after entire recovery
Properties | Test method | Tubes RUC |
---|---|---|
Operating temperature: | IEC216 | -55°C to +125°C |
Tensile strength | ASTM D 2671 | > 14 MPa |
Elongation at rupture | ASTM D 2671 | > 400% |
Length change after shrinking | UL224 | 0 ±5% |
Elongation at rupture after heat ageing | 158 °C, 168h | > 300% |
Inflammability test | VW-1 | positive |
Dielectric resistance | 1EC 243 | > 20 kV/mm |
Volume resistivity | IEC93 | >10" O./cm |
Infuence on copper | ASTM D 2671 | doesn't corrode |
Your review appreciation cannot be sent
Report comment
Report sent
Your report cannot be sent
Eigenen Kommentar verfassen
Review sent
Your review cannot be sent