Technical Data
Thermoplastic material | UL94-V0 |
Operating frequency | 50-60Hz |
Voltage | 0.72kV |
Test voltage | 3kV * 1’50Hz |
Insulation | Klasa E |
Protection degree | IP 20 |
Continuous overcurrent | 1.2In |
Rated short-time thermal current (I th) | 80 In |
Rated dynamic current (I dyn) | 2.5 x I th |
Safety factor | N<5 |
max. power dissipation (max range value) | <16W |
Operating temperature | -25 +50o C |
Storage temperature | -40+80o C |
Manufactured according to |
IEC/E N 60044-1, |
SECONDARY 5A
Ratio | Burdens [VA] |
Code | |
---|---|---|---|
cl. 0.5 | cl. 1 | ||
400/5 A | 4 | 8 |
TAT080400X05 |
500/5 A | 6 | 12 |
TAT080500X05 |
600/5 A | 10 | 20 |
TAT080600X05 |
800/5 A | 15 | 30 |
TAT080800X05 |
1000/5 A | 20 | 40 |
TAT0801K0X05 |
1200/5 A | 30 | 60 |
TAT0801K2X05 |
1500/5 A | 40 | 80 |
TAT0801K5X05 |
2000/5 A | 50 | 100 |
TAT0802K0X05 |
2500/5 A | 60 | 120 |
TAT0802K5X05 |
SECONDARY 1A
Ratio | Burdens [VA] |
Code | |
---|---|---|---|
cl. 0.5 | cl. 1 | ||
400/1 A | 4 | 8 |
TAT080400X01 |
500/1 A | 6 | 12 |
TAT080500X01 |
600/1 A | 10 | 20 |
TAT080600X01 |
800/1 A | 15 | 30 |
TAT080800X01 |
1000/1 A | 20 | 40 |
TAT0801K0X01 |
1200/1 A | 30 | 60 |
TAT0801K2X01 |
1500/1 A | 40 | 80 |
TAT0801K5X01 |
2000/1 A | 50 | 100 |
TAT0802K0X01 |
2500/1 A | 60 | 120 |
TAT0802K5X01 |
Dimensions
Interessieren Sie sich für dieses Produkt? Benötigen Sie zusätzliche Informationen oder individuelle Preise?
Sie müssen eingeloggt sein
Technical Data
Thermoplastic material | UL94-V0 |
Operating frequency | 50-60Hz |
Voltage | 0.72kV |
Test voltage | 3kV * 1’50Hz |
Insulation | Klasa E |
Protection degree | IP 20 |
Continuous overcurrent | 1.2In |
Rated short-time thermal current (I th) | 80 In |
Rated dynamic current (I dyn) | 2.5 x I th |
Safety factor | N<5 |
max. power dissipation (max range value) | <16W |
Operating temperature | -25 +50o C |
Storage temperature | -40+80o C |
Manufactured according to |
IEC/E N 60044-1, |
SECONDARY 5A
Ratio | Burdens [VA] |
Code | |
---|---|---|---|
cl. 0.5 | cl. 1 | ||
400/5 A | 4 | 8 |
TAT080400X05 |
500/5 A | 6 | 12 |
TAT080500X05 |
600/5 A | 10 | 20 |
TAT080600X05 |
800/5 A | 15 | 30 |
TAT080800X05 |
1000/5 A | 20 | 40 |
TAT0801K0X05 |
1200/5 A | 30 | 60 |
TAT0801K2X05 |
1500/5 A | 40 | 80 |
TAT0801K5X05 |
2000/5 A | 50 | 100 |
TAT0802K0X05 |
2500/5 A | 60 | 120 |
TAT0802K5X05 |
SECONDARY 1A
Ratio | Burdens [VA] |
Code | |
---|---|---|---|
cl. 0.5 | cl. 1 | ||
400/1 A | 4 | 8 |
TAT080400X01 |
500/1 A | 6 | 12 |
TAT080500X01 |
600/1 A | 10 | 20 |
TAT080600X01 |
800/1 A | 15 | 30 |
TAT080800X01 |
1000/1 A | 20 | 40 |
TAT0801K0X01 |
1200/1 A | 30 | 60 |
TAT0801K2X01 |
1500/1 A | 40 | 80 |
TAT0801K5X01 |
2000/1 A | 50 | 100 |
TAT0802K0X01 |
2500/1 A | 60 | 120 |
TAT0802K5X01 |
Dimensions