

Sie müssen eingeloggt sein
Category
Montaż urządzeń
Modernizacja induktorów
Urządzenia indukcyjne
asd
Fotos dienen nur zu Informationszwecken.
please use latin characters
The biggest advantage of split core current transformers is their easy installation. They could be mounted on the various conductors without the need to disconnect the grid.
There are 4 types of protection CT for measuring up to 5000A in classes: 5P5, 5P10 i 5P15.
Type | Ratio | Code | |||||
---|---|---|---|---|---|---|---|
VA | 5P5 | VA | 5P10 | VA | 5P15 | ||
TAA032 21x32 | 200/5A | 2 | TAA032200K05 | ||||
250/5A | 2,5 | TAA032250K05 | |||||
300/5A | 2,5 | TAA032300K05 | |||||
400/5A | 5 | TAA032400K05 | |||||
TAA082 50x81 | 400/5A | 3 | TAA082400K05 | ||||
500/5A | 4 | TAA082500K05 | |||||
600/5A | 5 | TAA082600K05 | |||||
800/5A | 3 | TAA082800K05 | 1 | TAA082800L05 | |||
1000/5A | 5 | TAA0821K0K05 | 1 | TAA0821K0L05 | |||
TAA122 80,5x120 | 800/5A | 3 | TAA122800K05 | 1 | TAA122800L05 | ||
1000/5A | 5 | TAA1221K0K05 | 1 | TAA1221K0L05 | |||
1200/5A | 5 | TAA1221K2K05 | 1 | TAA1221K2L05 | |||
1500/5A | 7 | TAA1221K5K05 | 1 | TAA1221K5L05 | |||
TAA162 80,5x161 | 1000/5A | 20 | TAA1621K0K05 | 6 | TAA1621K0L05 | 1 | TAA1621K0M05 |
1500/5A | 25 | TAA1621K5K05 | 10 | TAA1621K5L05 | 1 | TAA1621K5M05 | |
2000/5A | 45 | TAA1622K0K05 | 15 | TAA1622K0L05 | 3 | TAA1622K0M05 | |
2500/5A | 50 | TAA1622K5K05 | 15 | TAA1622K5L05 | 2 | TAA1622K5M05 | |
3000/5A | 60 | TAA1623K0K05 | 20 | TAA1623K0L05 | 2 | TAA1623K0M05 | |
4000/5A | 80 | TAA1624K0K05 | 25 | TAA1624K0L05 | 2 | TAA1624K0M05 | |
5000/5A | 100 | TAA1625K0K05 | 30 | TAA1625K0L05 | 2 | TAA1625K0M05 |
Technical data
Self estinguishing | UL94-V0 |
---|---|
Thermoplastic material | 50-60Hz |
Insulation reference voltage | 0.72V |
Test voltage | 3 kV 1min. 50 Hz |
Insulation | E |
Protection degree | IP 20 |
Continous overcurrent | 1,2 In |
Rated short-time thermal current (Ith) | 60 In |
Rated dynamic current (I dyn) | 2.5 x I th |
Safety factor | N < 5 |
Operating temperature | -5 +50 ˚C |
Storage temperature | -20 +80 ˚C |
Manufactured according to | IEC/EN 6044-1, VDE, BS, UTE |
Integrated secondary terminals | 6 mm2 |
Sealable termina covers | integrated |
Supplied accessories:
- busbar fixing
- Insulated protective caps for busbar mounting
- C.T. fixing wall mounting fixing feet
Primary and secondary connections marking
Options
Vibration proof version |
VACXXXAVB |
Tropicalisation |
VACXXXTRP |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
Interessieren Sie sich für dieses Produkt? Benötigen Sie zusätzliche Informationen oder individuelle Preise?
Sie müssen eingeloggt sein
The biggest advantage of split core current transformers is their easy installation. They could be mounted on the various conductors without the need to disconnect the grid.
There are 4 types of protection CT for measuring up to 5000A in classes: 5P5, 5P10 i 5P15.
Type | Ratio | Code | |||||
---|---|---|---|---|---|---|---|
VA | 5P5 | VA | 5P10 | VA | 5P15 | ||
TAA032 21x32 | 200/5A | 2 | TAA032200K05 | ||||
250/5A | 2,5 | TAA032250K05 | |||||
300/5A | 2,5 | TAA032300K05 | |||||
400/5A | 5 | TAA032400K05 | |||||
TAA082 50x81 | 400/5A | 3 | TAA082400K05 | ||||
500/5A | 4 | TAA082500K05 | |||||
600/5A | 5 | TAA082600K05 | |||||
800/5A | 3 | TAA082800K05 | 1 | TAA082800L05 | |||
1000/5A | 5 | TAA0821K0K05 | 1 | TAA0821K0L05 | |||
TAA122 80,5x120 | 800/5A | 3 | TAA122800K05 | 1 | TAA122800L05 | ||
1000/5A | 5 | TAA1221K0K05 | 1 | TAA1221K0L05 | |||
1200/5A | 5 | TAA1221K2K05 | 1 | TAA1221K2L05 | |||
1500/5A | 7 | TAA1221K5K05 | 1 | TAA1221K5L05 | |||
TAA162 80,5x161 | 1000/5A | 20 | TAA1621K0K05 | 6 | TAA1621K0L05 | 1 | TAA1621K0M05 |
1500/5A | 25 | TAA1621K5K05 | 10 | TAA1621K5L05 | 1 | TAA1621K5M05 | |
2000/5A | 45 | TAA1622K0K05 | 15 | TAA1622K0L05 | 3 | TAA1622K0M05 | |
2500/5A | 50 | TAA1622K5K05 | 15 | TAA1622K5L05 | 2 | TAA1622K5M05 | |
3000/5A | 60 | TAA1623K0K05 | 20 | TAA1623K0L05 | 2 | TAA1623K0M05 | |
4000/5A | 80 | TAA1624K0K05 | 25 | TAA1624K0L05 | 2 | TAA1624K0M05 | |
5000/5A | 100 | TAA1625K0K05 | 30 | TAA1625K0L05 | 2 | TAA1625K0M05 |
Technical data
Self estinguishing | UL94-V0 |
---|---|
Thermoplastic material | 50-60Hz |
Insulation reference voltage | 0.72V |
Test voltage | 3 kV 1min. 50 Hz |
Insulation | E |
Protection degree | IP 20 |
Continous overcurrent | 1,2 In |
Rated short-time thermal current (Ith) | 60 In |
Rated dynamic current (I dyn) | 2.5 x I th |
Safety factor | N < 5 |
Operating temperature | -5 +50 ˚C |
Storage temperature | -20 +80 ˚C |
Manufactured according to | IEC/EN 6044-1, VDE, BS, UTE |
Integrated secondary terminals | 6 mm2 |
Sealable termina covers | integrated |
Supplied accessories:
- busbar fixing
- Insulated protective caps for busbar mounting
- C.T. fixing wall mounting fixing feet
Primary and secondary connections marking
Options
Vibration proof version |
VACXXXAVB |
Tropicalisation |
VACXXXTRP |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
Your review appreciation cannot be sent
Report comment
Report sent
Your report cannot be sent
Eigenen Kommentar verfassen
Review sent
Your review cannot be sent