IM-04DCCT Insulation monitoring relay
  • IM-04DCCT Insulation monitoring relay
  • IM-04DCCT Insulation monitoring relay

Photos are for informational purposes only. View product specification

please use latin characters

Manufacturer: Trafox

IM-04DCCT Insulation monitoring relay

Insulation monitoring relay for DC charging stations

  • Designed for use in demanding environments
  • Suitable for use with converters
  • Measures insulation resistance and capacitance of AC/DC networks
  • Detects symmetrical insulation faults
  • A wide range of applications - DC charging stations, DC networks
  • Rated system voltage 0...1000 VDC
  • N/C and N/O selectable
  • Modbus RTU
  • Automatic adaptation to leakage of capacitance up to 5 uF
  • Selectable start delay
  • Compliant with IEC 61851-23

MEASUREMENT SPECIFICATION

Maximum input voltage 1000VDC / 690 VAC
Resistance measurement range 10kΩ...1MΩ
Capacitance measurement range 100nF-5uF
System frequency DC, 10Hz - 500Hz
Start delay 0...30 s

POWER SPECIFICATION

Nominal input voltage 110-240 VAC, 110-300 VDC
Line frequency 15 - 460 Hz

GENERAL

Dimensions (W x L x D) IM-04DCCT 54 x 110 x 62 mm
Housing material plastic
Mounting interface DIN rail clamp or screw mounting
Temperature range -25°C … + 55°C

STANDARDS

Measurement IEC 61557-8:2014
Security IEC 61010-1:2010 (wydanie trzecie)
IEC 60664-1 i IEC 60664-3
EMC IEC 61326-2-4
CISPR 11 / EN55011
IEC61000-4-2
IEC61000-4-3
IEC61000-4-4
IEC61000-4-5
IEC61000-4-6
IEC61000-4-11
traction vehicle IEC 61851-23
charging station IEC 61851-23

Send an inquiry

Are you interested in this product? Do you need additional information or individual pricing?

Contact us
ASK FOR THE PRODUCT close
Thank you for sending your message. We will respond as soon as possible.
ASK FOR THE PRODUCT close
Browse

Add to Wishlist

You must be logged in

Insulation monitoring relay for DC charging stations

  • Designed for use in demanding environments
  • Suitable for use with converters
  • Measures insulation resistance and capacitance of AC/DC networks
  • Detects symmetrical insulation faults
  • A wide range of applications - DC charging stations, DC networks
  • Rated system voltage 0...1000 VDC
  • N/C and N/O selectable
  • Modbus RTU
  • Automatic adaptation to leakage of capacitance up to 5 uF
  • Selectable start delay
  • Compliant with IEC 61851-23

MEASUREMENT SPECIFICATION

Maximum input voltage 1000VDC / 690 VAC
Resistance measurement range 10kΩ...1MΩ
Capacitance measurement range 100nF-5uF
System frequency DC, 10Hz - 500Hz
Start delay 0...30 s

POWER SPECIFICATION

Nominal input voltage 110-240 VAC, 110-300 VDC
Line frequency 15 - 460 Hz

GENERAL

Dimensions (W x L x D) IM-04DCCT 54 x 110 x 62 mm
Housing material plastic
Mounting interface DIN rail clamp or screw mounting
Temperature range -25°C … + 55°C

STANDARDS

Measurement IEC 61557-8:2014
Security IEC 61010-1:2010 (wydanie trzecie)
IEC 60664-1 i IEC 60664-3
EMC IEC 61326-2-4
CISPR 11 / EN55011
IEC61000-4-2
IEC61000-4-3
IEC61000-4-4
IEC61000-4-5
IEC61000-4-6
IEC61000-4-11
traction vehicle IEC 61851-23
charging station IEC 61851-23