Size1

Show filters
Hide filtersFiltrationShow filters X
Manufacturers
more... less
Supply voltage
more... less
Width
more... less
Height
more... less
Depth
more... less
Frequency
more... less
Sound pressure level
more... less
Air flow rate (Axial fan)
more... less
Air flow rate (Centrifugal fan optional)
more... less
Ambient temperature operating limits
more... less
Head available
more... less
Compressor type
more... less
Digital thermostat
more... less
Fan type
more... less
Type of fluid
more... less
IN / OUT fluid connections
more... less
IP class
more... less
Current draw
more... less
Power consumption
more... less
The maximum size of the oil contamination
more... less
Nominal head available
more... less
Nominal / maximum fluid flow rate
more... less
Pump type
more... less
Quantity
more... less
Number of circuits
more... less
Rated Cooling Capacity
more... less
Refrigerant gas
more... less
Secondary supply voltage
more... less
Adjustable fluid temperature range
more... less
Temperature accuracy
more... less
Net weight (approximate)
more... less
In stock
more... less
Dostępne nośniki
Środowisko
Filter
Information close
Products that are marked "On Order" in the "Available Quantity" column are usually not in stock. Such products are available for purchase, however, due to their limited customer base, they usually have higher minimum quantities. DACPOL offers products that are not in stock for the following reasons: DACPOL currently has a large number of electronic components in stock and adds new products every day, however, tens of thousands of additional components and their various variants are available from our suppliers. Even though it is unreasonable to have all these products in stock due to the limited sales, we believe that it is in the best interest of our customers to make them available. Our goal is to inform customers about the maximum number of products available and enable them to make decisions based on specifications, prices, availability, required minimums and our technical advice. Please note that selecting the "In Stock" checkbox may limit the display to only products available for delivery straight from the shelf.
PDF Image
Manufacturer
Product name
View the product No. Manufacturer
Quantity available
Supply voltage
Width
Height
Depth
Frequency
Sound pressure level
Air flow rate (Axial fan)
Air flow rate (Centrifugal fan optional)
Ambient temperature operating limits
Head available
Compressor type
Digital thermostat
Fan type
Type of fluid
IN / OUT fluid connections
IP class
Current draw
Power consumption
The maximum size of the oil contamination
Nominal head available
Nominal / maximum fluid flow rate
Pump type
Quantity
Number of circuits
Rated Cooling Capacity
Refrigerant gas
Secondary supply voltage
Adjustable fluid temperature range
Temperature accuracy
Net weight (approximate)
-- TCU15 50Hz Chillers Industrial to liquids polluted or dirty TEXA industries TCU15 50Hz Chillers Industrial to liquids polluted or dirty SEE IT TCU15 50Hz On Order 230V (+/-10%) 1ph 50/60Hz V ph Hz 595 mm 995 mm 678 mm 50 Hz 57 ... 60 dB(A) 2300 ... 2650 m3/h 2100 ... 2400 m3/h 15 ... 45 °C 250 Pa tłokowy TX110 Osiowy Zanieczyszczone płyny (emulsje olejów i olejów mineralnych) 3/4" 44 IP 5.6 A 1030 W 150 μm 3.2 bar 14 ... 55 l/min Odśrodkowy 1 no. 1 - 1 no. 1600 W R134a HFC 230 V 25 ... 40 °C /- 2 K 130 kg
-- TCU15 60Hz Chillers Industrial to liquids polluted or dirty TEXA industries TCU15 60Hz Chillers Industrial to liquids polluted or dirty SEE IT TCU15 60Hz On Order 230V (+/-10%) 1ph 50/60Hz V ph Hz 595 mm 995 mm 678 mm 60 Hz 57 ... 60 dB(A) 2300 ... 2650 m3/h 2100 ... 2400 m3/h 15 ... 45 °C 250 Pa tłokowy TX110 Osiowy Zanieczyszczone płyny (emulsje olejów i olejów mineralnych) 3/4" 44 IP 5.8 A 1060 W 150 μm 3.2 bar 14 ... 55 l/min Odśrodkowy 1 no. 1 - 1 no. 1900 W R134a HFC 230 V 25 ... 40 °C /- 2 K 130 kg
-- TCU22 50Hz Chillers Industrial to liquids polluted or dirty TEXA industries TCU22 50Hz Chillers Industrial to liquids polluted or dirty SEE IT TCU22 50Hz On Order 230V (+/-10%) 1ph 50/60Hz V ph Hz 595 mm 995 mm 678 mm 50 Hz 57 ... 60 dB(A) 2300 ... 2650 m3/h 2100 ... 2400 m3/h 15 ... 45 °C 250 Pa tłokowy TX110 Osiowy Zanieczyszczone płyny (emulsje olejów i olejów mineralnych) 3/4" 44 IP 6.1 A 1150 W 150 μm 3.2 bar 14 ... 55 l/min Odśrodkowy 1 no. 1 - 1 no. 2200 W R134a HFC 230 V 25 ... 40 °C /- 2 K 132 kg
-- TCU22 60Hz Chillers Industrial to liquids polluted or dirty TEXA industries TCU22 60Hz Chillers Industrial to liquids polluted or dirty SEE IT TCU22 60Hz On Order 230V (+/-10%) 1ph 50/60Hz V ph Hz 595 mm 995 mm 678 mm 60 Hz 57 ... 60 dB(A) 2300 ... 2650 m3/h 2100 ... 2400 m3/h 15 ... 45 °C 250 Pa tłokowy TX110 Osiowy Zanieczyszczone płyny (emulsje olejów i olejów mineralnych) 3/4" 44 IP 8.1 A 1500 W 150 μm 3.2 bar 14 ... 55 l/min Odśrodkowy 1 no. 1 - 1 no. 2550 W R134a HFC 230 V 25 ... 40 °C /- 2 K 132 kg
-- TCU36 50Hz Industrial chillers to liquids polluted or dirty TEXA industries TCU36 50Hz Industrial chillers to liquids polluted or dirty SEE IT TCU36 50Hz On Order 230V (+/-10%) 1ph 50/60Hz V ph Hz 595 mm 995 mm 678 mm 50 Hz 57 ... 60 dB(A) 2300 ... 2650 m3/h 2100 ... 2400 m3/h 15 ... 45 °C 250 Pa tłokowy TX110 Osiowy Zanieczyszczone płyny (emulsje olejów i olejów mineralnych) 3/4" 44 IP 9.4 A 1730 W 150 μm 3.0 bar 18 ... 55 l/min Odśrodkowy 1 no. 1 - 1 no. 3300 W R134a HFC 230 V 25 ... 40 °C /- 2 K 132 kg
-- TCU36 60Hz Chillers Industrial to liquids polluted or dirty TEXA industries TCU36 60Hz Chillers Industrial to liquids polluted or dirty SEE IT TCU36 60Hz On Order 230V (+/-10%) 1ph 50/60Hz V ph Hz 595 mm 995 mm 678 mm 60 Hz 57 ... 60 dB(A) 2300 ... 2650 m3/h 2100 ... 2400 m3/h 15 ... 45 °C 250 Pa tłokowy TX110 Osiowy Zanieczyszczone płyny (emulsje olejów i olejów mineralnych) 3/4" 44 IP 0:00 AM 2220 W 150 μm 3.0 bar 18 ... 55 l/min Odśrodkowy 1 no. 1 - 1 no. 3900 W R134a HFC 230 V 25 ... 40 °C /- 2 K 132 kg
Results per page: