TCI series

Categories

Show filters
Hide filtersFiltrationShow filters X
Manufacturers
more... less
Supply voltage
more... less
Width
more... less
Height
more... less
Depth
more... less
Frequency
more... less
Sound pressure level
more... less
Air flow rate (Axial fan)
more... less
Ambient temperature operating limits
more... less
Compressor type
more... less
Digital thermostat
more... less
Fan type
more... less
IP class
more... less
Current draw
more... less
Power consumption
more... less
Minimum fluid flow (emulsion / oil)
more... less
Minimum volume in the tank (emulsion / oil)
more... less
Quantity
more... less
Number of circuits
more... less
Rated Cooling Capacity
more... less
Refrigerant gas
more... less
Secondary supply voltage
more... less
Adjustable fluid temperature range
more... less
Temperature accuracy
more... less
Net weight (approximate)
more... less
Filter
Information close
Products that are marked "On Order" in the "Available Quantity" column are usually not in stock. Such products are available for purchase, however, due to their limited customer base, they usually have higher minimum quantities. DACPOL offers products that are not in stock for the following reasons: DACPOL currently has a large number of electronic components in stock and adds new products every day, however, tens of thousands of additional components and their various variants are available from our suppliers. Even though it is unreasonable to have all these products in stock due to the limited sales, we believe that it is in the best interest of our customers to make them available. Our goal is to inform customers about the maximum number of products available and enable them to make decisions based on specifications, prices, availability, required minimums and our technical advice. Please note that selecting the "In Stock" checkbox may limit the display to only products available for delivery straight from the shelf.
PDF Image
Manufacturer
Product name
View the product No. Manufacturer
Quantity available
Supply voltage
Width
Height
Depth
Frequency
Sound pressure level
Air flow rate (Axial fan)
Ambient temperature operating limits
Compressor type
Digital thermostat
Fan type
IP class
Current draw
Power consumption
Minimum fluid flow (emulsion / oil)
Minimum volume in the tank (emulsion / oil)
Quantity
Number of circuits
Rated Cooling Capacity
Refrigerant gas
Secondary supply voltage
Adjustable fluid temperature range
Temperature accuracy
Net weight (approximate)
-- TCI56 50Hz chillers with immersion coil TEXA industries TCI56 50Hz chillers with immersion coil SEE IT TCI56 50Hz On Order 400/460V (+/-10%) 3ph 50/60Hz V ph Hz 550 mm 1432 mm 550 mm 50 Hz 57 dB(A) 2000 m3/h -5 .. 45 °C Spiralny TX110 Osiowy 44 IP 5.4 A 3700 W 40 ... 60 l/min 60 ... 100 l. 1 no. 1 - 1 no. 6000 W R134a HFC 230V-24V AC V 15 / 25 Woda lub emulsja max 5 cSt - 40°C 20 / 30 olej mineralny 32 cSt - 40°C °C /- 1 K 145 kg
-- Tcia7 50hz chillers with immersion coil TEXA industries Tcia7 50hz chillers with immersion coil SEE IT TCIA7 50Hz On Order 400/460V (+/-10%) 3ph 50/60Hz V ph Hz 549 mm 1636 mm 1002 mm 50 Hz 60 dB(A) 4300 m3/h -5 .. 45 °C Spiralny TX110 Osiowy 44 IP 12.5 A 4100 W 80 ... 120 l/min 150 - 250 l. 2 no. 1 - 1 no. 17800 W R410A HFC 230V-24V AC V 15 / 25 Woda lub emulsja max 5 cSt - 40°C 20 / 30 olej mineralny 32 cSt - 40°C °C /- 1 K 215 kg
-- Tcia4 60hz chillers with immersion coil TEXA industries Tcia4 60hz chillers with immersion coil SEE IT TCIA4 60Hz On Order 400/460V (+/-10%) 3ph 50/60Hz V ph Hz 549 mm 1636 mm 1002 mm 60 Hz 60 dB(A) 4300 m3/h -5 .. 45 °C Spiralny TX110 Osiowy 44 IP 11.8 A 4300 W 80 ... 120 l/min 150 - 250 l. 2 no. 1 - 1 no. 19400 W R410A HFC 230V-24V AC V 15 / 25 Woda lub emulsja max 5 cSt - 40°C 20 / 30 olej mineralny 32 cSt - 40°C °C /- 1 K 215 kg
-- Tcia4 50hz chillers with immersion coil TEXA industries Tcia4 50hz chillers with immersion coil SEE IT TCIA4 50Hz On Order 400/460V (+/-10%) 3ph 50/60Hz V ph Hz 549 mm 1636 mm 1002 mm 50 Hz 60 dB(A) 4300 m3/h -5 .. 45 °C Spiralny TX110 Osiowy 44 IP 12.1 A 4000 W 80 ... 120 l/min 150 ... 250 l. 2 no. 1 - 1 no. 16400 W R410A HFC 230V-24V AC V 15 / 25 Woda lub emulsja max 5 cSt - 40°C 20 / 30 olej mineralny 32 cSt - 40°C °C /- 1 K 215 kg
-- Tcia2 60hz chillers with immersion coil TEXA industries Tcia2 60hz chillers with immersion coil SEE IT TCIA2 60Hz On Order 400/460V (+/-10%) 3ph 50/60Hz V ph Hz 549 mm 1636 mm 1002 mm 60 Hz 60 dB(A) 4300 m3/h -5 .. 45 °C Spiralny TX110 Osiowy 44 IP 9.6 A 3500 W 80 ... 120 l/min 150 ... 250 l. 2 no. 1 - 1 no. 14600 W R410A HFC 230V-24V AC V 15 / 25 Woda lub emulsja max 5 cSt - 40°C 20 / 30 olej mineralny 32 cSt - 40°C °C /- 1 K 215 kg
-- TCIA2 50Hz Chillers with immersion coil TEXA industries TCIA2 50Hz Chillers with immersion coil SEE IT TCIA2 50Hz On Order 400/460V (+/-10%) 3ph 50/60Hz V ph Hz 549 mm 1636 mm 1002 mm 50 Hz 60 dB(A) 4300 m3/h -5 .. 45 °C Spiralny TX110 Osiowy 44 IP 9.8 A 3100 W 80 ... 120 l/min 150 ... 250 l. 2 no. 1 - 1 no. 12300 W R410A HFC 230V-24V AC V 15 / 25 Woda lub emulsja max 5 cSt - 40°C 20 / 30 olej mineralny 32 cSt - 40°C °C /- 1 K 215 kg
-- TCI91 60Hz chillers with immersion coil TEXA industries TCI91 60Hz chillers with immersion coil SEE IT TCI91 60Hz On Order 400/460V (+/-10%) 3ph 50/60Hz V ph Hz 550 mm 1432 mm 550 mm 60 Hz 57 dB(A) 2000 m3/h -5 .. 45 °C Spiralny TX110 Osiowy 44 IP 6.9 A 3600 W 40 ... 60 l/min 60 ... 100 l. 1 no. 1 - 1 no. 11000 W R134a HFC 230V-24V AC V 15 / 25 Woda lub emulsja max 5 cSt - 40°C 20 / 30 olej mineralny 32 cSt - 40°C °C /- 1 K 150 kg
-- TCI91 50Hz chillers with immersion coil TEXA industries TCI91 50Hz chillers with immersion coil SEE IT TCI91 50Hz On Order 400/460V (+/-10%) 3ph 50/60Hz V ph Hz 550 mm 1432 mm 550 mm 50 Hz 57 dB(A) 2000 m3/h -5 .. 45 °C Spiralny TX110 Osiowy 44 IP 6.0 A 2900 W 40 ... 60 l/min 60 ... 100 l. 1 no. 1 - 1 no. 9200 W R134a HFC 230V-24V AC V 15 / 25 Woda lub emulsja max 5 cSt - 40°C 20 / 30 olej mineralny 32 cSt - 40°C °C /- 1 K 150 kg
-- TCI70 60Hz chillers with immersion coil TEXA industries TCI70 60Hz chillers with immersion coil SEE IT TCI70 60Hz On Order 400/460V (+/-10%) 3ph 50/60Hz V ph Hz 550 mm 1432 mm 550 mm 60 Hz 57 dB(A) 2000 m3/h -5 .. 45 °C Spiralny TX110 Osiowy 44 IP 8.0 A 5100 W 40 ... 60 l/min 60 ... 100 l. 1 no. 1 - 1 no. 9650 W R134a HFC 230V-24V AC V 15 / 25 Woda lub emulsja max 5 cSt - 40°C 20 / 30 olej mineralny 32 cSt - 40°C °C /- 1 K 147 kg
-- TCI70 50Hz Chillers with immersion coil TEXA industries TCI70 50Hz Chillers with immersion coil SEE IT TCI70 50Hz On Order 400/460V (+/-10%) 3ph 50/60Hz V ph Hz 550 mm 1432 mm 550 mm 50 Hz 57 dB(A) 2000 m3/h -5 .. 45 °C Spiralny TX110 Osiowy 44 IP 7.1 A 4200 W 40 ... 60 l/min 60 ... 100 l. 1 no. 1 - 1 no. 8100 W R134a HFC 230V-24V AC V 15 / 25 Woda lub emulsja max 5 cSt - 40°C 20 / 30 olej mineralny 32 cSt - 40°C °C /- 1 K 147 kg
-- TCI56 60Hz chillers with immersion coil TEXA industries TCI56 60Hz chillers with immersion coil SEE IT TCI56 60Hz On Order 400/460V (+/-10%) 3ph 50/60Hz V ph Hz 550 mm 1432 mm 550 mm 60 Hz 57 dB(A) 2000 m3/h -5 .. 45 °C Spiralny TX110 Osiowy 44 IP 6.3 A 4500 W 40 ... 60 l/min 60 ... 100 l. 1 no. 1 - 1 no. 7100 W R134a HFC 230V-24V AC V 15 / 25 Woda lub emulsja max 5 cSt - 40°C 20 / 30 olej mineralny 32 cSt - 40°C °C /- 1 K 145 kg
-- Tcia7 60hz chillers with immersion coil TEXA industries Tcia7 60hz chillers with immersion coil SEE IT TCIA7 60Hz On Order 400/460V (+/-10%) 3ph 50/60Hz V ph Hz 549 mm 1636 mm 1002 mm 60 Hz 60 dB(A) 4300 m3/h -5 .. 45 °C Spiralny TX110 Osiowy 44 IP 12.1 A 4700 W 80 ... 120 l/min 150 - 250 l. 2 no. 1 - 1 no. 20450 W R410A HFC 230V-24V AC V 15 / 25 Woda lub emulsja max 5 cSt - 40°C 20 / 30 olej mineralny 32 cSt - 40°C °C /- 1 K 215 kg
Results per page: