SOLITHERM PELTIER

Show filters
Hide filtersFiltrationShow filters X
Manufacturers
more... less
Working temp. range
more... less
Dimensions
more... less
Rated current
more... less
Weight
more... less
Voltage frequency
more... less
Mounting methods
more... less
Current draw
more... less
Starting current
more... less
Connection
more... less
Max. Current
more... less
Max. Power
more... less
Cooling capacity of L35L35
more... less
Cut Out Dimension
more... less
Current L35L35
more... less
Nominal power L35L35
more... less
Fuse
more... less
Air Flow Volume (System / Unimpeded)
more... less
In stock
more... less
Dostępne nośniki
Środowisko
Filter
Information close
Products that are marked "On Order" in the "Available Quantity" column are usually not in stock. Such products are available for purchase, however, due to their limited customer base, they usually have higher minimum quantities. DACPOL offers products that are not in stock for the following reasons: DACPOL currently has a large number of electronic components in stock and adds new products every day, however, tens of thousands of additional components and their various variants are available from our suppliers. Even though it is unreasonable to have all these products in stock due to the limited sales, we believe that it is in the best interest of our customers to make them available. Our goal is to inform customers about the maximum number of products available and enable them to make decisions based on specifications, prices, availability, required minimums and our technical advice. Please note that selecting the "In Stock" checkbox may limit the display to only products available for delivery straight from the shelf.
PDF Image
Manufacturer
Product name
View the product No. Manufacturer
Quantity available
Working temp. range
Dimensions
Rated current
Weight
Voltage frequency
Mounting methods
Current draw
Starting current
Connection
Max. Current
Max. Power
Cooling capacity of L35L35
Cut Out Dimension
Current L35L35
Nominal power L35L35
Air Flow Volume (System / Unimpeded)
-- Thermoelectric cooling unit 3030305 SEIFERT mtm SYSTEM Thermoelectric cooling unit 3030305 SEE IT 3030305 On Order -20°C - +65°C 212 x 158 x 131 mm -- 2.6 kg 12 V DC (używa dostaw NEC klasy 2) Naścienny (z ramą) -- 4.3 A -- 2.9 A 35 W 30 W 180 x 128 mm 2.8 A 34 W -- Obieg powietrza z otoczenia - 39 / 75 m³/h Obieg powietrza szafy - 20 / 62 m³/h
-- Thermoelectric cooling unit 3200310 SEIFERT mtm SYSTEM Thermoelectric cooling unit 3200310 SEE IT 3200310 On Order -20°C - +65°C 500 x 188 x 174 mm -- 13.7 kg 48 V DC Naścienny (z ramą) -- 9.5 A -- 7.5 A 360 W 200 W 469 x 155 mm 4.7 A 226 W -- Obieg powietrza z otoczenia - 120 / 260 m³/h Obieg powietrza szafy - 120 / 260 m³/h
-- Thermoelectric cooling unit 6105303 SEIFERT mtm SYSTEM Thermoelectric cooling unit 6105303 SEE IT 6105303 On Order -20°C - +65°C 280 X 350 x 165 (113+52) mm -- 9.4 kg 120 - 230 V ~ 50/60 Hz Wpuszczany -- 1.6 A @ 120 V 0.8 A @ 230 V -- 1.1 A @ 120 V 0.6 A @ 230 V 131 W 100 W 350 x 280 mm 1.0 A @ 120 V 0.5 A @ 230 V 125 W -- Obieg powietrza z otoczenia - 128 / 213 m³/h Obieg powietrza szafy - 46 / 90 m³/h
-- Thermoelectric cooling unit 6105305 SEIFERT mtm SYSTEM Thermoelectric cooling unit 6105305 SEE IT 6105305 On Order -20°C - +65°C 280 x 350 x 165 mm -- 11 kg 120 - 230 V ~ 50/60 Hz Naścienny (z ramą) -- 1.6 A @ 120 V 0.8 A @ 230 V -- 1.1 A @ 120 V 0.6 A @ 230 V 131 W 100 W 350 x 280 mm 1.0 A @ 120 V 0.5 A @ 230 V 125 W -- Obieg powietrza z otoczenia - 128 / 213 m³/h Obieg powietrza szafy - 46 / 90 m³/h
-- Thermoelectric cooling unit 6155303 SEIFERT mtm SYSTEM Thermoelectric cooling unit 6155303 SEE IT 6155303 On Order -20°C - +65°C 500 x 330 x 196 (130+66) mm -- 18 kg 120 - 230 V ~ 50/60 Hz Wpuszczany -- 2.1 A @ 120 V 1.1 A @ 230 V -- 1.5 A @ 120 V 0.8 A @ 230 V 180 W 150 W 244 x 428 mm 1.4 A @ 120 V 0.7 A @ 230 V 170 W -- Obieg powietrza z otoczenia - 120 / 260 m³/h Obieg powietrza szafy - 60 / 170 m³/h
-- Thermoelectric cooling unit 6155305 SEIFERT mtm SYSTEM Thermoelectric cooling unit 6155305 SEE IT 6155305 On Order -20°C - +65°C 500 x 330 x 200 mm -- 19 kg 120 - 230 V ~ 50/60 Hz Naścienny (z ramą) -- 2.1 A @ 120 V 1.1 A @ 230 V -- 1.5 A @ 120 V 0.8 A @ 230 V 180 W 150 W -- 1.4 A @ 120 V 0.7 A @ 230 V 170 W -- Obieg powietrza z otoczenia - 120 / 260 m³/h Obieg powietrza szafy - 60 / 170 m³/h
-- Thermoelectric cooling unit 6205303 SEIFERT mtm SYSTEM Thermoelectric cooling unit 6205303 SEE IT 6205303 On Order -20°C - +65°C 500 x 330 x 196 (130+66) mm -- 17.2 kg 120 - 230 V ~ 50/60 Hz Wpuszczany -- 3.2 A @ 120 V 1.7 A @ 230 V -- 2.2 A @ 120 V 1.2 A @ 230 V 270 W 200 W 472 x 302 mm 2.1 A @ 120 V 1.1 A @ 230 V 250 W -- Obieg powietrza z otoczenia - 106 / 260 m³/h Obieg powietrza szafy - 150 / 260 m³/h
-- Thermoelectric cooling unit 6205305 SEIFERT mtm SYSTEM Thermoelectric cooling unit 6205305 SEE IT 6205305 On Order -20°C - +65°C 500 x 330 x 200 mm -- 21 kg 120 - 230 V ~ 50/60 Hz Naścienny (z ramą) -- 3.2 A @ 120 V 1.7 A @ 230 V -- 2.2 A @ 120 V 1.2 A @ 230 V 270 W 200 W 244 x 428 mm 2.1 A @ 120 V 1.1 A @ 230 V 250 W -- Obieg powietrza z otoczenia - 106 / 260 m³/h Obieg powietrza szafy - 150 / 260 m³/h
-- Thermoelectric cooling unit 6405303 SEIFERT mtm SYSTEM Thermoelectric cooling unit 6405303 SEE IT 6405303 On Order -20°C - +65°C 600 x 432 x 202 (135+67) mm -- 34 kg 120 - 230 V ~ 50/60 Hz Wpuszczany -- 6.5 A @ 120 V 3.4 A @ 230 V -- 4.5 A @ 120 V 2.3 A @ 230 V 537 W 400 W 382 x 550 mm 4.1 A @ 120 V 2.1 A @ 230 V 490 W -- Obieg powietrza z otoczenia - 240 / 325 m³/h Obieg powietrza szafy - 240 / 325 m³/h
-- Thermoelectric cooling unit 6405305 SEIFERT mtm SYSTEM Thermoelectric cooling unit 6405305 SEE IT 6405305 On Order -20°C - +65°C 600 x 432 x 207.5 mm -- 37 kg 120 - 230 V ~ 50/60 Hz Naścienny (z ramą) -- 6.5 A @ 120 V 3.4 A @ 230 V -- 4.5 A @ 120 V 2.3 A @ 230 V 537 W 400 W 382 x 550 mm 4.1 A @ 120 V 2.1 A @ 230 V 490 W -- Obieg powietrza z otoczenia - 240 / 325 m³/h Obieg powietrza szafy - 240 / 325 m³/h
-- Thermoelectric cooling unit 6805303 SEIFERT mtm SYSTEM Thermoelectric cooling unit 6805303 SEE IT 6805303 On Order -20°C- +65°C 972 x 514 x 211 (135.5+75.5) mm -- 66 kg 120 - 230 V ~ 50/60 Hz Wpuszczany -- 14 A @ 120 V 8 A @ 230 V -- 9 A @ 120 V 4.7 A @ 230 V 1078 W 800 W 464 x 922 mm 8.2 A @ 120 V 4.3 A @ 230 V 979 W -- Obieg powietrza z otoczenia - 480 / 650 m³/h Obieg powietrza szafy - 480 / 650 m³/h
-- Thermoelectric cooling unit 3200308 SEIFERT mtm SYSTEM Thermoelectric cooling unit 3200308 SEE IT 3200308 On Order -20°C - +65°C 400 x 180 x 171 (81+90) mm -- 10 kg 48 V DC Wpuszczany -- 9.5 A -- 7.5 A 360 W 200 W 370 x 155 mm 4.7 A 226 W -- Obieg powietrza z otoczenia - 120 / 260 m³/h Obieg powietrza szafy - 120 / 260 m³/h
-- Thermoelectric cooling unit 3200305 SEIFERT mtm SYSTEM Thermoelectric cooling unit 3200305 SEE IT 3200305 On Order -20°C - +65°C 500 x 188 x 174 mm -- 13.7 kg 24 V DC Naścienny (z ramą) -- 17.1 A -- 13.5 A 324 W 200 W 469 x 155 mm 9.4 A 226 W -- Obieg powietrza z otoczenia - 120 / 260 m³/h Obieg powietrza szafy - 120 / 260 m³/h
-- Thermoelectric cooling unit 3030303 SEIFERT mtm SYSTEM Thermoelectric cooling unit 3030303 SEE IT 3030303 On Order -20°C - +65°C 110 x 154 x 128 (65+63) mm -- 1.8 kg 12 V DC (używa dostaw NEC klasy 2) Wpuszczany -- 4.3 A -- 2.9 A 35 W 30 W 122 x 90 mm 2.8 A 34 W -- Obieg powietrza z otoczenia - 39 / 75 m³/h Obieg powietrza szafy - 20 / 62 m³/h
-- Thermoelectric cooling unit 3035303 SEIFERT mtm SYSTEM Thermoelectric cooling unit 3035303 SEE IT 3035303 On Order -20°C - +65°C 110 x 154 x 134 mm 2:00 AM 1.8 kg 24 V DC (używa dostaw NEC klasy 2) Wpuszczany 44 W 4:00 AM Blok zacisków przyłączeniowych -- -- 30 W 122 x 82 mm -- -- 5 A (T) Obieg powietrza z otoczenia - 39 / 75 m³/h Obieg powietrza szafy - 20 / 62 m³/h
-- Thermoelectric cooling unit 3035305 SEIFERT mtm SYSTEM Thermoelectric cooling unit 3035305 SEE IT 3035305 On Order -20°C - +65°C 212 x 158 x 131 mm 3:00 AM 2.6 kg 24 V DC (używa dostaw NEC klasy 2) Naścienny (z ramą) 72 W 4:00 AM Blok zacisków przyłączeniowych -- -- 30 W 180 x 128 mm -- -- 5 A (T) Obieg powietrza z otoczenia - 39 / 75 m³/h Obieg powietrza szafy - 20 / 62 m³/h
-- Thermoelectric cooling unit 3050303 SEIFERT mtm SYSTEM Thermoelectric cooling unit 3050303 SEE IT 3050303 On Order -20°C - +65°C 206 x 154 x 135 (75+60) mm -- 3.3 kg 24 V DC (używa dostaw NEC klasy 2) Wpuszczany -- 3.7 A -- 2.5 A 60 W 50 W 170 x 120 mm 2.4 A 58 W -- Obieg powietrza z otoczenia - 64 / 170 m³/h Obieg powietrza szafy - 23 / 72 m³/h
-- Thermoelectric cooling unit 3050305 SEIFERT mtm SYSTEM Thermoelectric cooling unit 3050305 SEE IT 3050305 On Order -20°C - +65°C 302 x 158 x 137 mm -- 3.9 kg 24 V DC (używa dostaw NEC klasy 2) Naścienny (z ramą) -- 3.7 A -- 2.5 A 60 W 50 W 270 x 130 mm 2.4 A 58 W -- Obieg powietrza z otoczenia - 64 / 170 m³/h Obieg powietrza szafy - 23 / 72 m³/h
-- Thermoelectric cooling unit 3102303 SEIFERT mtm SYSTEM Thermoelectric cooling unit 3102303 SEE IT 3102303 On Order -20°C - +65°C 200 x 304 x 138 (74+64) mm -- 5.9 kg 24 V DC Wpuszczany -- 7.4 A -- 4.9 A 118 W 100 W 260 x 160 mm 4.8 A 124 W -- Obieg powietrza z otoczenia - 128 / 213 m³/h Obieg powietrza szafy - 46 / 90 m³/h
-- Thermoelectric cooling unit 3102305 SEIFERT mtm SYSTEM Thermoelectric cooling unit 3102305 SEE IT 3102305 On Order -20°C - +65°C 302 x 306 x 140 mm -- 7.4 kg 24 V DC Naścienny (z ramą) -- 7.4 A -- 4.9 A 118 W 100 W 270 x 270 mm 4.8 A 124 W -- Obieg powietrza z otoczenia - 128 / 213 m³/h Obieg powietrza szafy - 46 / 90 m³/h
-- Thermoelectric cooling unit 3152303 SEIFERT mtm SYSTEM Thermoelectric cooling unit 3152303 SEE IT 3152303 On Order -20°C - +65°C 400 x 180 x 171 (81+90) mm -- 9 kg 24 V DC Wpuszczany -- 11:00 AM -- 7.5 A 180 W 150 W 370 x 155 mm 6.3 A 170 W -- Obieg powietrza z otoczenia - 120 / 260 m³/h Obieg powietrza szafy - 60 / 170 m³/h
-- Thermoelectric cooling unit 3152305 SEIFERT mtm SYSTEM Thermoelectric cooling unit 3152305 SEE IT 3152305 On Order -20°C - +65°C 500 x 188 x 174 mm -- 12.7 kg 24 V DC Naścienny (z ramą) -- 11:00 AM -- 7.5 A 180 W 150 W 469 x 155 mm 6.3 A 170 W -- Obieg powietrza z otoczenia - 120 / 260 m³/h Obieg powietrza szafy - 60 / 170 m³/h
-- Thermoelectric cooling unit 3200303 SEIFERT mtm SYSTEM Thermoelectric cooling unit 3200303 SEE IT 3200303 On Order -20°C - +65°C 400 x 180 x 171 (81+90) mm -- 10 kg 24 V DC Wpuszczany -- 17.1 A -- 13.5 A 324 W 200 W 370 x 155 mm 9.4 A 226 W -- Obieg powietrza z otoczenia - 120 / 260 m³/h Obieg powietrza szafy - 120 / 260 m³/h
-- Thermoelectric cooling unit 6805305 SEIFERT mtm SYSTEM Thermoelectric cooling unit 6805305 SEE IT 6805305 On Order -20°C- +65°C 972 x 514 x 211 mm -- 70 kg 120 - 230 V ~ 50/60 Hz Naścienny (z ramą) -- 14 A @ 120 V 8 A @ 230 V -- 9 A @ 120 V 4.7 A @ 230 V 1078 W 800 W 464 x 922 mm 8.2 A @ 120 V 4.3 A @ 230 V 979 W -- Obieg powietrza z otoczenia - 480 / 650 m³/h Obieg powietrza szafy - 480 / 650 m³/h
Results per page: