The AHM1 is designed to be used for the measurement and calculation of electrical variables such as voltage, current, frequency, power, power factor, energy, harmonic components, etc.
The AHM1-RC (Rogoswski coil version) has a built-in 8 MB memory, which allows you to register 32 000 measurements andshows an easy-wire connection very useful for existing switchboards.
|
ELECTRICAL PARAMETER | UNIT | L1 | L2 | L3 | TOTAL | MAX/MIN | DEMAND |
---|---|---|---|---|---|---|---|
Voltage (Phase - Phase) | V, kV | • | • | • | • | ||
Voltage (Phase - Neutral) | V, kV | • | • | • | • | ||
Current | A, kA | • | • | • | • | • | |
Neutral current | A, kA | • | |||||
Active power (P) | kW, MW, GW | • | • | • | • | • | • |
Reactive power (Q) | kvar, Mvar, Gvar | • | • | • | • | • | • |
Apparent power (S) | kVA | • | • | • | • | • | • |
Power factor (Cos φ) | PF | • | • | • | • | • | |
Frequency | Hz | • | • | ||||
Import active energy (EP+) | Wh, MWh, GWh | • | |||||
Export active energy (EP-) | kWh, MWh, GWh | • | |||||
Import reactive energy (Eq+) | kvarh, Mvarh ,Gvarh | • | |||||
Export reactive energy (Eq-) | kvarh, Mvarh, Gvarh | • | |||||
Hour meter | h: min | • | |||||
THD Current and Voltage | A, V | • | • | • | |||
Harmonic RMS-U and I (1-31) | % | • | • | • | |||
Unbalanced -U and I | % | • |
|
Overload:
|
||||||||||
2 digital inputs:
|
2 contact outputs:
|
|
|
||||||||||||||||||||||||||||||
|
|
||||||||||||||||||||||||||||||
** Class 0.2 (25 ˚C) and Class 0.5 (-10 to 60oC) |
Are you interested in this product? Do you need additional information or individual pricing?
The AHM1 is designed to be used for the measurement and calculation of electrical variables such as voltage, current, frequency, power, power factor, energy, harmonic components, etc.
The AHM1-RC (Rogoswski coil version) has a built-in 8 MB memory, which allows you to register 32 000 measurements andshows an easy-wire connection very useful for existing switchboards.
|
ELECTRICAL PARAMETER | UNIT | L1 | L2 | L3 | TOTAL | MAX/MIN | DEMAND |
---|---|---|---|---|---|---|---|
Voltage (Phase - Phase) | V, kV | • | • | • | • | ||
Voltage (Phase - Neutral) | V, kV | • | • | • | • | ||
Current | A, kA | • | • | • | • | • | |
Neutral current | A, kA | • | |||||
Active power (P) | kW, MW, GW | • | • | • | • | • | • |
Reactive power (Q) | kvar, Mvar, Gvar | • | • | • | • | • | • |
Apparent power (S) | kVA | • | • | • | • | • | • |
Power factor (Cos φ) | PF | • | • | • | • | • | |
Frequency | Hz | • | • | ||||
Import active energy (EP+) | Wh, MWh, GWh | • | |||||
Export active energy (EP-) | kWh, MWh, GWh | • | |||||
Import reactive energy (Eq+) | kvarh, Mvarh ,Gvarh | • | |||||
Export reactive energy (Eq-) | kvarh, Mvarh, Gvarh | • | |||||
Hour meter | h: min | • | |||||
THD Current and Voltage | A, V | • | • | • | |||
Harmonic RMS-U and I (1-31) | % | • | • | • | |||
Unbalanced -U and I | % | • |
|
Overload:
|
||||||||||
2 digital inputs:
|
2 contact outputs:
|
|
|
||||||||||||||||||||||||||||||
|
|
||||||||||||||||||||||||||||||
** Class 0.2 (25 ˚C) and Class 0.5 (-10 to 60oC) |