-
BackX
-
Components
-
-
Category
-
Semiconductors
- Diodes
- Thyristors
-
Electro-insulated Modules
- Electro-insulated Modules | VISHAY (IR)
- Electro-insulated Modules | INFINEON (EUPEC)
- Electro-insulated Modules | Semikron
- Electro-insulated Modules | POWEREX
- Electro-insulated Modules | IXYS
- Electro-insulated Modules | POSEICO
- Electro-insulated Modules | ABB
- Electro-insulated Modules | TECHSEM
- Go to the subcategory
- Bridge Rectifiers
-
Transistors
- Transistors | GeneSiC
- SiC MOSFET Modules | Mitsubishi
- SiC MOSFET Modules | STARPOWER
- Module SiC MOSFET ABB’s
- IGBT Modules | MITSUBISHI
- Transistor Modules | MITSUBISHI
- MOSFET Modules | MITSUBISHI
- Transistor Modules | ABB
- IGBT Modules | POWEREX
- IGBT Modules | INFINEON (EUPEC)
- Silicon Carbide (SiC) semiconductor elements
- Go to the subcategory
- Gate Drivers
- Power Blocks
- Go to the subcategory
-
Electrical Transducers
-
Current Transducers | LEM
- Closed-Loop Current Transducers (C/L)
- Open-Loop Current Transducers (O/L)
- Current Transducers supplied with unipolar voltage
- 'Eta' Current Transducers
- Current Transducers - LF xx10 Series
- Current Transducers - LH Series
- Current Transducer - HOYL and HOYS Series
- Current Transducers - GO–SME & GO–SMS Series
- AUTOMOTIVE current transducers
- Go to the subcategory
-
Voltage Transducers | LEM
- Voltage Transducers - LV Series
- Voltage Transducers - DVL Series
- Precision Voltage Transducers with double magnetic core - CV Series
- Voltage Transducer for Traction - DV 4200/SP4
- Voltage Transducers - DVM Series
- Voltage Transducer - DVC 1000-P
- Voltage Transducers - DVC 1000 Series
- Go to the subcategory
- Precision Current Transducers | LEM
- Go to the subcategory
-
Current Transducers | LEM
-
Passive components (capacitors, resistors, fuses, filters)
- Resistors
-
Fuses
- Miniature Fuses for electronic circuits - ABC & AGC Series
- Tubular Fast-acting Fuses
- Time-delay Fuse Links with GL/GG & AM characteristics
- Ultrafast Fuse Links
- Fast-acting Fuses (British & American standard)
- Fast-acting Fuses (European standard)
- Traction Fuses
- High-voltage Fuse Links
- Go to the subcategory
- Capacitors
- EMI Filters
- Supercapacitors
- Power surge protection
- Go to the subcategory
-
Relays and Contactors
- Relays and Contactors - Theory
- 3-Phase AC Semiconductor Relays
- DC Semiconductor Relays
- Controllers, Control Systems and Accessories
- Soft Starters and Reversible Relays
- Electromechanical Relays
- Contactors
- Rotary Switches
-
Single-Phase AC Semiconductor Relays
- AC ONE PHASE RELAYS 1 series| D2425 | D2450
- One phase semiconductor AC relays CWA and CWD series
- One phase semiconductor AC relays CMRA and CMRD series
- One phase semiconductor AC relays - PS series
- Double and quadruple semiconductor AC relays - D24 D, TD24 Q, H12D48 D series
- One phase semiconductor relays - gn series
- Ckr series single phase solid state relays
- One phase AC semiconductor relays for DIN bus - ERDA I ERAA series
- 150A AC single phase relays
- Rail Mountable Solid State Relays With Integrated Heat Sink - ENDA, ERDA1 / ERAA1 series
- Go to the subcategory
- Single-Phase AC Semiconductor Relays for PCBs
- Interface Relays
- Go to the subcategory
- Cores and Other Inductive Components
- Heatsinks, Varistors, Thermal Protection
- Fans
- Air Conditioning, Accessories for Electrical Cabinets, Coolers
-
Batteries, Chargers, Buffer Power Supplies and Inverters
- Batteries, Chargers - Theoretical Description
- Modular Li-ion Battery Building Blocks, Custom Batteries, BMS
- Batteries
- Battery Chargers and Accessories
- Uninterruptible Power Supply and Buffer Power Supplies
- Inverters and Photovoltaic Equipments
- Energy storage
- Fuel cells
- Lithium-ion batteries
- Go to the subcategory
-
Automatics
- Futaba Drone Parts
- Limit Switches, Microswitches
- Sensors, Transducers
-
Infrared Thermometers (Pyrometers)
- IR-TE Series - Water-proof Palm-sized Radiation Thermometer
- IR-TA Series - Handheld Type Radiation Thermometer
- IR-H Series - Handheld Type Radiation Thermometer
- IR-BA Series - High-speed Compact Radiation Thermometer
- IR-FA Series - Fiber Optic Radiation Thermometer
- IR-BZ Series - Compact Infrared Thermometers
- Go to the subcategory
- Counters, Time Relays, Panel Meters
- Industrial Protection Devices
- Light and Sound Signalling
- Thermographic Camera
- LED Displays
- Control Equipments
-
Recorders
- Hybrid Recorders - AL3000 Series | CHINO
- Graphic Recorder - KR2000 Series | CHINO
- Ubiquitous Recorders - KR5000 Series | CHINO
- Palm-sized Temperature/Humidity Meters - HN-CH Series | CHINO
- Consumables for Recorders
- 71VR1 - Compact Paperless Recorder | M-SYSTEM
- Graphic Recorder - KR3000 Series | CHINO
- PC Recorders - R1M Series | M-SYSTEM
- PC Recorders - R2M Series | M-SYSTEM
- PC Recorders - RZMS Series | M-SYSTEM
- PC Recorders - RZUS Series | M-SYSTEM
- Go to the subcategory
- Go to the subcategory
-
Cables, Litz wires, Conduits, Flexible connections
- Wires
- Litz wires
- Cables for extreme applications
- Sleevings
-
Braids
- Flat Braids
- Round Braids
- Very Flexible Flat Braids
- Very Flexible Round Braids
- Cylindrical Cooper Braids
- Cylindrical Cooper Braids and Sleevings
- Flexible Earthing Connections
- Galvanized and Stainless Steel Cylindrical Braids
- PCV Insulated Copper Braids (temp. up to 85C)
- Flat Aluminium Braids
- Junction Set - Braids and Tubes
- Go to the subcategory
- Traction Equipment
- Cable Terminals
- Flexible Insulated Busbars
- Flexible Multilayer Busbars
- Cable Duct Systems
- Hoses
- Go to the subcategory
- View all categories
-
Semiconductors
-
-
- Suppliers
-
Applications
- CNC Machine Tools
- DC and AC Drives (Inverters)
- Energetics
- Energy bank
- Equipment and Components for Hazardous Areas [Ex]
- Equipment for Distribution, Control and Telecommunications Cabinets
- HVAC Automation
- Induction Heating
- Industrial Automation
- Industrial Protective Devices
- Machines for Drying and Wood Processing
- Machines for Thermoforming Plastics
- Mining, Metallurgy and Foundry
- Motors and Transformers
- Power Supplies (UPS) and Rectifier Systems
- Printing
- Temperature Measurement and Regulation
- Test and Laboratory Measurements
- Tram and Railway Traction
- Welding Machines
-
Assembly
-
-
Montaż urządzeń
- Assembly of equipment on request
- Designing and Assembling of Busbar Cabinets, Switching Cabinets, Power Cabinets
- Power systems installation
- Components
- Machines built for order
- R&D research and development work
-
Industrial Testers
- Tester for diodes and thyristors measurement
- Thermal and motor circuit breakers testing stand
- Varistors and surge protectors testers
- Car fuses testing stand
- Tester for the power diode and thyristor reverse recovery charge Qrr measurement
- Rotor tester FD series
- Circuit breakers tester
- Tester for calibrating relays
- Video inspection tester for gas spring piston rods
- High-current thyristor switch
- Mesh ripping tester
- Go to the subcategory
- View all categories
-
-
-
Inductors
-
-
Modernizacja induktorów
- Repair of used inductors
- Modernization of inductors
-
Production of new inductors
- Inductors for crankshaft hardening
- Hardening of band saw teeth
- Inductors for heating elements before gluing
- Hardening of raceways of automotive wheel hub bearings
- Hardening of the drive transmission components
- Hardening of stepped shafts
- Heating in contraction joints
- Induction for scanning hardening
- Soft soldering
- Billet heaters
- Go to the subcategory
- Knowledge base
- View all categories
-
-
-
Induction devices
-
-
Urządzenia indukcyjne
-
Induction heating generators
-
Induction Heating Products Ambrell
- Generators power 500 W, frequency 150 - 400 kHz
- Generators power 1.2 - 2.4 kW, frequency 150 - 400 kHz
- Generators power 4.2 - 10 kW, frequency 150 - 400 kHz
- Generators power 10-15 kW, frequency 50-150 kHz
- Generators power 30-45 kW, frequency 50-150 kHz
- Generators power 65-135 kW, frequency 50-150 kHz
- Generators power 180-270 kW, frequency 50-150 kHz
- Generators power 20-35-50 kW, frequency 15-45 kHz
- Generators power 75-150 kW, frequency 15-45 kHz
- Generators power 200-500 kW, frequency 15-45 kHz
- Generators power 20-50 kW, frequency 5-15 kHz
- Go to the subcategory
- Induction heating products Denki Kogyo
-
JKZ induction heating generators
- Generators CX, frequency: 50-120kHz, power: 5-25kW
- Generators SWS, frequency: 15-30kHz, power: 25-260kW
- Molding and forging furnaces MFS, frequency: 0,5-10kHz, power: 80-500kW
- Melting metals furnaces MFS, frequency: 0,5-10kHz, power: 70-200kW
- Generators UHT, frequency: 200-400kHz, power: 10-160kW
- Go to the subcategory
- Lamp generators for induction heating
- Induction Heating Products - Himmelwerk
- Go to the subcategory
-
Induction Heating Products Ambrell
- Repairs and modernization
- Peripherals
-
Applications
- Medical Applications with Precision Induction Heating
- Applications for automotive industry
- Soldering
- Brazing
- Aluminum Brazing
- Brazing a magnetic steel cutting tool
- Pin Sealing
- Atmospheric Brazing
- Soldering brass and steel radiator caps
- Carbide Tipping
- Soldering a copper lug and a wire
- Go to the subcategory
- Knowledge base
- View all categories
-
Induction heating generators
-
-
-
Service
-
-
asd
- Service of industrial water coolers and air conditioners
- Machines Repairs and Modernizations
- Repair and Maintenance of Power Electronics, Electronic and Industrial Automation Devices
- HV Power Supplies for Electrostatic Precipitators
- Industrial Printers and Labelling Machines
- Certificates / Entitlements
- View all categories
-
-
- Contact
- Zobacz wszystkie kategorie
Photos are for informational purposes only. View product specification
please use latin characters
Bimetallic and combined ammeters are especially intended for thermal monitoring of transformers, cables and other electrical devices which have a slow reaction to current changes.
They indicate the mean rms current value during the measuring period of the meter (8 or 15 min.). These meters do not react to short current pulses essentially. The range of these meters can be enlarged by means of external measuring current transformers which are also offered by LUMEL and can be delivered on request if the meter is ordered in the option enabling a direct assembling on the current transformer.
ACCESSORIES We deliver together with the meter:
|
TECHNICAL SPECIFICATIONS |
Measuring ranges of the bimetallic ammeters |
Measuring ranges of the bimetallic movement |
Measuring ranges of the electromagnetic movement |
Current transformer |
---|---|---|
0...1 A | 0...1/2 A | x/1 A |
0...5 A | 0...5/10 A | x/5 A |
Accuracy class: | |
- bimetallic movement (BA27, BA39, BE27, BE39) | 3 |
- moving-iron movement (BE27, BE39) | 1,5 |
Additional errors in limits of rated operating conditions | acc. to EN 60051-1 |
Averaging time of bimetalic movement | 8 or 15 min. |
Response time of the moving-iron movement (BE27, BE39) | 1 s |
Self consumption: | |
- bimetallic movement (BA27, BA39, BE27, BE39) | x/1A max. 1,2 VA |
x/5A max. 2,5 VA | |
- moving-iron movement (in BE types only) | 0,45 VA |
Protection grade ensured by: | wg PN-EN 60529 |
- housing | IP50 |
- terminals | IP 20 (with a protective terminal cover) |
Used materials: | |
- material of the housing | thermoplasic material (ABS) |
- material of the base | thermoplasic material (PPE) |
- material of the window | glass |
Safety requirements | acc. EN 61010 - 1 |
- installation category | III |
- protection degree | 2 |
- maximal working voltage in relation to the earth | 300 V AC |
Electromagnetic compatibility | |
All ammeters fulfill CE mark requirements. | |
- emission | acc. EN 61000-6-4 |
- immunity | acc. EN 61000-6-4 |
External dimensions: | |
- BA27 and BE27 executions | 72 x 72 x 61,5mm |
- BA39 and BE39 executions | 96 x 96 x 61,5mm |
Weight: | |
- BA27 | 0,16 kg |
- BE27 | 0,20 kg |
- BA39 | 0,22 kg |
- BE39 | 0,27 kg |
Categories of climatic versions
If there is not given in the order, meters are destined to be applied in closed rooms, not air conditioned, in conditions of a moderate climate, acc. to EN 60051 standard. On request, meters can be adapted to be used in a dry or wet tropical climate also in closed, not air conditioned rooms. They are then marked by the TIII symbol.
Working temperature range of meters
These meters operate without damage in the temperature range: from -25oC to +40oC, in accordance with the binding standards.
Matching of meter measuring ranges to current transformer ranges:Through the dial exchange. The exchange way is shown in the user,s
manual.
Types | a | b | d |
---|---|---|---|
BA27 and BE27 |
68+0,7 | 72 | 61,5 |
BA39 and BE39 |
92+0,8 | 96 | 61,5 |
Range code | Range description (measuring range) |
Range code |
Range description (measuring range) |
---|---|---|---|
F201 | 1,2 A | F366 | 1920 A 1,6k/1 |
F205 | 6 A | F4 | 1,2XA X/5 |
F3 | 1,2XA X/1 | F405 | 6 A 5/5 |
F301 | 1,2 A 1/1 | F406 | 7,2 A 6/5 |
F305 | 6 A 5/1 | F407 | 12 A 10/5 |
F306 | 7,2 A 6/1 | F408 | 18 A 15/5 |
F307 | 12 A 10/1 | F409 | 24 A 20/5 |
F308 | 18 A 15/1 | F411 | 36 A 30/5 |
F309 | 24 A 20/1 | F412 | 48 A 40/5 |
F311 | 36 A 30/1 | F413 | 60 A 50/5 |
F312 | 48 A 40/1 | F414 | 72 A 60/5 |
F313 | 60 A 50/1 | F415 | 96 A 80/5 |
F314 | 72 A 60/1 | F416 | 120 A 100/5 |
F315 | 96 A 80/1 | F417 | 180 A 150/5 |
F316 | 120 A 100/1 | F418 | 240 A 200/5 |
F317 | 180 A 150/1 | F420 | 360 A 300/5 |
F318 | 240 A 200/1 | F421 | 480 A 400/5 |
F320 | 360 A 300/1 | F422 | 600 A 500/5 |
F321 | 480 A 400/1 | F423 | 720 A 600/5 |
F322 | 600 A 500/1 | F424 | 960 A 800/5 |
F323 | 720 A 600/1 | F450 | 1200 A 1k/5 |
F324 | 960 A 800/1 | F451 | 1800 A 1,5k/5 |
F350 | 1200 A 1k/1 | F452 | 2400 A 2k/5 |
F351 | 1800 A 1,5k/1 | F454 | 3600 A 3k/5 |
F352 | 2400 A 2k/1 | F455 | 4800 A 4k/5 |
F354 | 3600 A 3k/1 | F456 | 6000 A 5k/5 |
F355 | 4800 A 4k/1 | F457 | 7200 A 6k/5 |
F356 | 6000 A 5k/1 | F459 | 12000 A 10k/5 |
F357 | 7200 A 6k/1 | F465 | 1440 A 1,2k/5 |
F359 | 12000 A 10k/1 | F466 | 1920 A 1,6k/5 |
F365 | 1440 A 1,2k/1 |
|
Ordering examples
Code: BE39-1-T-F421-1-A-1-7 means:
BE39 combined bimetallic and moving-iron ammeter, catalogue panel fixing version, TIII climate version, current range: 400/5 A, setting time: 8 min., working position: C1 (horizontal), percentage graduation 120% and 200%, delivered with a quality inspection certificate.
Code: BA27-1-N-F205-0-O-0-8 means:
BA27 bimetallic moving-iron ammeter, measuring range: 6 A, catalogue climatic version, setting time: 15 min., without additional requirements Code: BE39-1-T-F421-1-A-1-7 means:
BE39 combined bimetallic and moving-iron ammeter, catalogue panel fixing version, TIII climate version, current range: 400/5 A, setting time: 8 min., working position: C1 (horizontal), percentage graduation 120% and 200%, delivered with a quality inspection certificate.
Code: BA27-1-N-F205-0-O-0-8 means:
BA27 bimetallic moving-iron ammeter, measuring range: 6 A, catalogue climatic version, setting time: 15 min., without additional requirements
Send an inquiry
Are you interested in this product? Do you need additional information or individual pricing?
Contact us
Bimetallic and combined ammeters are especially intended for thermal monitoring of transformers, cables and other electrical devices which have a slow reaction to current changes.
They indicate the mean rms current value during the measuring period of the meter (8 or 15 min.). These meters do not react to short current pulses essentially. The range of these meters can be enlarged by means of external measuring current transformers which are also offered by LUMEL and can be delivered on request if the meter is ordered in the option enabling a direct assembling on the current transformer.
ACCESSORIES We deliver together with the meter:
|
TECHNICAL SPECIFICATIONS |
Measuring ranges of the bimetallic ammeters |
Measuring ranges of the bimetallic movement |
Measuring ranges of the electromagnetic movement |
Current transformer |
---|---|---|
0...1 A | 0...1/2 A | x/1 A |
0...5 A | 0...5/10 A | x/5 A |
Accuracy class: | |
- bimetallic movement (BA27, BA39, BE27, BE39) | 3 |
- moving-iron movement (BE27, BE39) | 1,5 |
Additional errors in limits of rated operating conditions | acc. to EN 60051-1 |
Averaging time of bimetalic movement | 8 or 15 min. |
Response time of the moving-iron movement (BE27, BE39) | 1 s |
Self consumption: | |
- bimetallic movement (BA27, BA39, BE27, BE39) | x/1A max. 1,2 VA |
x/5A max. 2,5 VA | |
- moving-iron movement (in BE types only) | 0,45 VA |
Protection grade ensured by: | wg PN-EN 60529 |
- housing | IP50 |
- terminals | IP 20 (with a protective terminal cover) |
Used materials: | |
- material of the housing | thermoplasic material (ABS) |
- material of the base | thermoplasic material (PPE) |
- material of the window | glass |
Safety requirements | acc. EN 61010 - 1 |
- installation category | III |
- protection degree | 2 |
- maximal working voltage in relation to the earth | 300 V AC |
Electromagnetic compatibility | |
All ammeters fulfill CE mark requirements. | |
- emission | acc. EN 61000-6-4 |
- immunity | acc. EN 61000-6-4 |
External dimensions: | |
- BA27 and BE27 executions | 72 x 72 x 61,5mm |
- BA39 and BE39 executions | 96 x 96 x 61,5mm |
Weight: | |
- BA27 | 0,16 kg |
- BE27 | 0,20 kg |
- BA39 | 0,22 kg |
- BE39 | 0,27 kg |
Categories of climatic versions
If there is not given in the order, meters are destined to be applied in closed rooms, not air conditioned, in conditions of a moderate climate, acc. to EN 60051 standard. On request, meters can be adapted to be used in a dry or wet tropical climate also in closed, not air conditioned rooms. They are then marked by the TIII symbol.
Working temperature range of meters
These meters operate without damage in the temperature range: from -25oC to +40oC, in accordance with the binding standards.
Matching of meter measuring ranges to current transformer ranges:Through the dial exchange. The exchange way is shown in the user,s
manual.
Types | a | b | d |
---|---|---|---|
BA27 and BE27 |
68+0,7 | 72 | 61,5 |
BA39 and BE39 |
92+0,8 | 96 | 61,5 |
Range code | Range description (measuring range) |
Range code |
Range description (measuring range) |
---|---|---|---|
F201 | 1,2 A | F366 | 1920 A 1,6k/1 |
F205 | 6 A | F4 | 1,2XA X/5 |
F3 | 1,2XA X/1 | F405 | 6 A 5/5 |
F301 | 1,2 A 1/1 | F406 | 7,2 A 6/5 |
F305 | 6 A 5/1 | F407 | 12 A 10/5 |
F306 | 7,2 A 6/1 | F408 | 18 A 15/5 |
F307 | 12 A 10/1 | F409 | 24 A 20/5 |
F308 | 18 A 15/1 | F411 | 36 A 30/5 |
F309 | 24 A 20/1 | F412 | 48 A 40/5 |
F311 | 36 A 30/1 | F413 | 60 A 50/5 |
F312 | 48 A 40/1 | F414 | 72 A 60/5 |
F313 | 60 A 50/1 | F415 | 96 A 80/5 |
F314 | 72 A 60/1 | F416 | 120 A 100/5 |
F315 | 96 A 80/1 | F417 | 180 A 150/5 |
F316 | 120 A 100/1 | F418 | 240 A 200/5 |
F317 | 180 A 150/1 | F420 | 360 A 300/5 |
F318 | 240 A 200/1 | F421 | 480 A 400/5 |
F320 | 360 A 300/1 | F422 | 600 A 500/5 |
F321 | 480 A 400/1 | F423 | 720 A 600/5 |
F322 | 600 A 500/1 | F424 | 960 A 800/5 |
F323 | 720 A 600/1 | F450 | 1200 A 1k/5 |
F324 | 960 A 800/1 | F451 | 1800 A 1,5k/5 |
F350 | 1200 A 1k/1 | F452 | 2400 A 2k/5 |
F351 | 1800 A 1,5k/1 | F454 | 3600 A 3k/5 |
F352 | 2400 A 2k/1 | F455 | 4800 A 4k/5 |
F354 | 3600 A 3k/1 | F456 | 6000 A 5k/5 |
F355 | 4800 A 4k/1 | F457 | 7200 A 6k/5 |
F356 | 6000 A 5k/1 | F459 | 12000 A 10k/5 |
F357 | 7200 A 6k/1 | F465 | 1440 A 1,2k/5 |
F359 | 12000 A 10k/1 | F466 | 1920 A 1,6k/5 |
F365 | 1440 A 1,2k/1 |
|
Ordering examples
Code: BE39-1-T-F421-1-A-1-7 means:
BE39 combined bimetallic and moving-iron ammeter, catalogue panel fixing version, TIII climate version, current range: 400/5 A, setting time: 8 min., working position: C1 (horizontal), percentage graduation 120% and 200%, delivered with a quality inspection certificate.
Code: BA27-1-N-F205-0-O-0-8 means:
BA27 bimetallic moving-iron ammeter, measuring range: 6 A, catalogue climatic version, setting time: 15 min., without additional requirements Code: BE39-1-T-F421-1-A-1-7 means:
BE39 combined bimetallic and moving-iron ammeter, catalogue panel fixing version, TIII climate version, current range: 400/5 A, setting time: 8 min., working position: C1 (horizontal), percentage graduation 120% and 200%, delivered with a quality inspection certificate.
Code: BA27-1-N-F205-0-O-0-8 means:
BA27 bimetallic moving-iron ammeter, measuring range: 6 A, catalogue climatic version, setting time: 15 min., without additional requirements
Your review appreciation cannot be sent
Report comment
Report sent
Your report cannot be sent
Write your review
Review sent
Your review cannot be sent