BackX
-
Components
-
-
Category
-
Semiconductors
- Diodes
- Thyristors
-
Electro-insulated Modules
- Electro-insulated Modules | VISHAY (IR)
- Electro-insulated Modules | INFINEON (EUPEC)
- Electro-insulated Modules | Semikron
- Electro-insulated Modules | POWEREX
- Electro-insulated Modules | IXYS
- Electro-insulated Modules | POSEICO
- Electro-insulated Modules | ABB
- Electro-insulated Modules | TECHSEM
- Go to the subcategory
- Bridge Rectifiers
-
Transistors
- Transistors | GeneSiC
- SiC MOSFET Modules | Mitsubishi
- SiC MOSFET Modules | STARPOWER
- Module SiC MOSFET ABB’s
- IGBT Modules | MITSUBISHI
- Transistor Modules | MITSUBISHI
- MOSFET Modules | MITSUBISHI
- Transistor Modules | ABB
- IGBT Modules | POWEREX
- IGBT Modules | INFINEON (EUPEC)
- Silicon Carbide (SiC) semiconductor elements
- Go to the subcategory
- Gate Drivers
- Power Blocks
- Go to the subcategory
-
Electrical Transducers
-
Current Transducers | LEM
- Closed-Loop Current Transducers (C/L)
- Open-Loop Current Transducers (O/L)
- Current Transducers supplied with unipolar voltage
- 'Eta' Current Transducers
- Current Transducers - LF xx10 Series
- Current Transducers - LH Series
- Current Transducer - HOYL and HOYS Series
- Current Transducers - GO–SME & GO–SMS Series
- AUTOMOTIVE current transducers
- Go to the subcategory
-
Voltage Transducers | LEM
- Voltage Transducers - LV Series
- Voltage Transducers - DVL Series
- Precision Voltage Transducers with double magnetic core - CV Series
- Voltage Transducer for Traction - DV 4200/SP4
- Voltage Transducers - DVM Series
- Voltage Transducer - DVC 1000-P
- Voltage Transducers - DVC 1000 Series
- Go to the subcategory
- Precision Current Transducers | LEM
- Go to the subcategory
-
Current Transducers | LEM
-
Passive components (capacitors, resistors, fuses, filters)
- Resistors
-
Fuses
- Miniature Fuses for electronic circuits - ABC & AGC Series
- Tubular Fast-acting Fuses
- Time-delay Fuse Links with GL/GG & AM characteristics
- Ultrafast Fuse Links
- Fast-acting Fuses (British & American standard)
- Fast-acting Fuses (European standard)
- Traction Fuses
- High-voltage Fuse Links
- Go to the subcategory
- Capacitors
- EMI Filters
- Supercapacitors
- Power surge protection
- Go to the subcategory
-
Relays and Contactors
- Relays and Contactors - Theory
- 3-Phase AC Semiconductor Relays
- DC Semiconductor Relays
- Controllers, Control Systems and Accessories
- Soft Starters and Reversible Relays
- Electromechanical Relays
- Contactors
- Rotary Switches
-
Single-Phase AC Semiconductor Relays
- AC ONE PHASE RELAYS 1 series| D2425 | D2450
- One phase semiconductor AC relays CWA and CWD series
- One phase semiconductor AC relays CMRA and CMRD series
- One phase semiconductor AC relays - PS series
- Double and quadruple semiconductor AC relays - D24 D, TD24 Q, H12D48 D series
- One phase semiconductor relays - gn series
- Ckr series single phase solid state relays
- One phase AC semiconductor relays for DIN bus - ERDA I ERAA series
- 150A AC single phase relays
- Rail Mountable Solid State Relays With Integrated Heat Sink - ENDA, ERDA1 / ERAA1 series
- Go to the subcategory
- Single-Phase AC Semiconductor Relays for PCBs
- Interface Relays
- Go to the subcategory
- Cores and Other Inductive Components
- Heatsinks, Varistors, Thermal Protection
- Fans
- Air Conditioning, Accessories for Electrical Cabinets, Coolers
-
Batteries, Chargers, Buffer Power Supplies and Inverters
- Batteries, Chargers - Theoretical Description
- Modular Li-ion Battery Building Blocks, Custom Batteries, BMS
- Batteries
- Battery Chargers and Accessories
- Uninterruptible Power Supply and Buffer Power Supplies
- Inverters and Photovoltaic Equipments
- Energy storage
- Fuel cells
- Lithium-ion batteries
- Go to the subcategory
-
Automatics
- Futaba Drone Parts
- Limit Switches, Microswitches
- Sensors, Transducers
-
Infrared Thermometers (Pyrometers)
- IR-TE Series - Water-proof Palm-sized Radiation Thermometer
- IR-TA Series - Handheld Type Radiation Thermometer
- IR-H Series - Handheld Type Radiation Thermometer
- IR-BA Series - High-speed Compact Radiation Thermometer
- IR-FA Series - Fiber Optic Radiation Thermometer
- IR-BZ Series - Compact Infrared Thermometers
- Go to the subcategory
- Counters, Time Relays, Panel Meters
- Industrial Protection Devices
- Light and Sound Signalling
- Thermographic Camera
- LED Displays
- Control Equipments
-
Recorders
- Hybrid Recorders - AL3000 Series | CHINO
- Graphic Recorder - KR2000 Series | CHINO
- Ubiquitous Recorders - KR5000 Series | CHINO
- Palm-sized Temperature/Humidity Meters - HN-CH Series | CHINO
- Consumables for Recorders
- 71VR1 - Compact Paperless Recorder | M-SYSTEM
- Graphic Recorder - KR3000 Series | CHINO
- PC Recorders - R1M Series | M-SYSTEM
- PC Recorders - R2M Series | M-SYSTEM
- PC Recorders - RZMS Series | M-SYSTEM
- PC Recorders - RZUS Series | M-SYSTEM
- Go to the subcategory
- Go to the subcategory
-
Cables, Litz wires, Conduits, Flexible connections
- Wires
- Litz wires
- Cables for extreme applications
- Sleevings
-
Braids
- Flat Braids
- Round Braids
- Very Flexible Flat Braids
- Very Flexible Round Braids
- Cylindrical Cooper Braids
- Cylindrical Cooper Braids and Sleevings
- Flexible Earthing Connections
- Galvanized and Stainless Steel Cylindrical Braids
- PCV Insulated Copper Braids (temp. up to 85C)
- Flat Aluminium Braids
- Junction Set - Braids and Tubes
- Go to the subcategory
- Traction Equipment
- Cable Terminals
- Flexible Insulated Busbars
- Flexible Multilayer Busbars
- Cable Duct Systems
- Hoses
- Go to the subcategory
- View all categories
-
Semiconductors
-
-
- Suppliers
-
Applications
- CNC Machine Tools
- DC and AC Drives (Inverters)
- Energetics
- Energy bank
- Equipment and Components for Hazardous Areas [Ex]
- Equipment for Distribution, Control and Telecommunications Cabinets
- HVAC Automation
- Induction Heating
- Industrial Automation
- Industrial Protective Devices
- Machines for Drying and Wood Processing
- Machines for Thermoforming Plastics
- Mining, Metallurgy and Foundry
- Motors and Transformers
- Power Supplies (UPS) and Rectifier Systems
- Printing
- Temperature Measurement and Regulation
- Test and Laboratory Measurements
- Tram and Railway Traction
- Welding Machines
-
Assembly
-
-
Montaż urządzeń
- Assembly of equipment on request
- Designing and Assembling of Busbar Cabinets, Switching Cabinets, Power Cabinets
- Power systems installation
- Components
- Machines built for order
- R&D research and development work
-
Industrial Testers
- Tester for diodes and thyristors measurement
- Thermal and motor circuit breakers testing stand
- Varistors and surge protectors testers
- Car fuses testing stand
- Tester for the power diode and thyristor reverse recovery charge Qrr measurement
- Rotor tester FD series
- Circuit breakers tester
- Tester for calibrating relays
- Video inspection tester for gas spring piston rods
- High-current thyristor switch
- Mesh ripping tester
- Go to the subcategory
- View all categories
-
-
-
Inductors
-
-
Modernizacja induktorów
- Repair of used inductors
- Modernization of inductors
-
Production of new inductors
- Inductors for crankshaft hardening
- Hardening of band saw teeth
- Inductors for heating elements before gluing
- Hardening of raceways of automotive wheel hub bearings
- Hardening of the drive transmission components
- Hardening of stepped shafts
- Heating in contraction joints
- Induction for scanning hardening
- Soft soldering
- Billet heaters
- Go to the subcategory
- Knowledge base
- View all categories
-
-
-
Induction devices
-
-
Urządzenia indukcyjne
-
Induction heating generators
-
Induction Heating Products Ambrell
- Generators power 500 W, frequency 150 - 400 kHz
- Generators power 1.2 - 2.4 kW, frequency 150 - 400 kHz
- Generators power 4.2 - 10 kW, frequency 150 - 400 kHz
- Generators power 10-15 kW, frequency 50-150 kHz
- Generators power 30-45 kW, frequency 50-150 kHz
- Generators power 65-135 kW, frequency 50-150 kHz
- Generators power 180-270 kW, frequency 50-150 kHz
- Generators power 20-35-50 kW, frequency 15-45 kHz
- Generators power 75-150 kW, frequency 15-45 kHz
- Generators power 200-500 kW, frequency 15-45 kHz
- Generators power 20-50 kW, frequency 5-15 kHz
- Go to the subcategory
- Induction heating products Denki Kogyo
-
JKZ induction heating generators
- Generators CX, frequency: 50-120kHz, power: 5-25kW
- Generators SWS, frequency: 15-30kHz, power: 25-260kW
- Molding and forging furnaces MFS, frequency: 0,5-10kHz, power: 80-500kW
- Melting metals furnaces MFS, frequency: 0,5-10kHz, power: 70-200kW
- Generators UHT, frequency: 200-400kHz, power: 10-160kW
- Go to the subcategory
- Lamp generators for induction heating
- Induction Heating Products - Himmelwerk
- Go to the subcategory
-
Induction Heating Products Ambrell
- Repairs and modernization
- Peripherals
-
Applications
- Medical Applications with Precision Induction Heating
- Applications for automotive industry
- Soldering
- Brazing
- Aluminum Brazing
- Brazing a magnetic steel cutting tool
- Pin Sealing
- Atmospheric Brazing
- Soldering brass and steel radiator caps
- Carbide Tipping
- Soldering a copper lug and a wire
- Go to the subcategory
- Knowledge base
- View all categories
-
Induction heating generators
-
-
-
Service
-
-
asd
- Service of industrial water coolers and air conditioners
- Machines Repairs and Modernizations
- Repair and Maintenance of Power Electronics, Electronic and Industrial Automation Devices
- HV Power Supplies for Electrostatic Precipitators
- Industrial Printers and Labelling Machines
- Certificates / Entitlements
- View all categories
-
-
- Contact
- Zobacz wszystkie kategorie
Photos are for informational purposes only. View product specification
please use latin characters
Type | Pn [W] at 40°C | Max Temp °C | R [Ω] min-max | Impulse Load [W] Temp, Ambient 40°C, cycle 120s | |||
---|---|---|---|---|---|---|---|
1-second Duty Cycle | 5-second Duty Cycle | 10-second Duty Cycle | 40-second Duty Cycle | ||||
СВН/ CBV 165 С | 110 | 265 | 0.5 - 1000 | 5 | 1.4 | 0.9 | 0.3 |
СВН/ CBV 215 С | 155 | 270 | 0.8 - 1500 | 9.8 | 2.5 | 1.6 | 0.5 |
СВН/ CBV 265 С | 200 | 270 | 1.5 - 2000 | 16.6 | 4 | 2.4 | 0.6 |
СВН/ CBV 335 С | 270 | 280 | 1.8 - 2000 | 26.6 | 6.2 | 3.4 | 0.9 |
СВН/ CBV 405 С | 330 | 285 | 2.0 - 2000 | 34.1 | 8.5 | 4.3 | 1 |
CBR-V/H175 С | 311 | 265 | 0.8 - 1500 | 10.5 | 2.7 | 1.8 | 0.9 |
CBR-V/ Н 225 С | 400 | 270 | 1.5 - 2000 | 18.3 | 4.5 | 2.8 | 1.2 |
CBR-V/ Н 295 С | 525 | 275 | 1.8 - 2000 | 29.7 | 7.1 | 4.2 | 1.8 |
CBR-V/ Н 365 С | 650 | 280 | 2.0 - 2000 | 38.4 | 11.3 | 6.7 | 2.4 |
CBR-V/ Н 426 С | 980 | 285 | 2.4 - 2000 | 39.1 | 12.9 | 7.9 | 2.9 |
CBR-V/ Н 526 С | 1220 | 295 | 3.0 - 2000 | 49.1 | 16.1 | 9.9 | 3.6 |
CBR-V/ Н 626 С | 1460 | 305 | 3.5 - 2000 | 60.6 | 19.7 | 12 | 4.4 |
CBR-V/ Н 726 С | 1700 | 310 | 4.0 - 2000 | 73.1 | 23.4 | 14.3 | 5.2 |
СВН/ CBV 165 С | 110 | 265 | 0.5 - 1000 | 5 | 1.4 | 0.9 | 0.3 |
Construction and Main Characteristics
- Approved by UL
- Compact dimensions
- Nominal power range from 110W to 1700W
- Energy levels from 9kJ to 150kJ (5-second duty cycle, cycle 120s), depending on resistance value
- Aluminum housing for high IP rating
- IP50-IP65
- Internal wire spirals wound on ceramics for lower resistance
- Nickel-chromium alloy 8020 for low thermal drift
- Mica insulation for high dielectric strength
- Filled with Al2O3 or SiO2 for high thermal capacity/overload capability
- Low surface temperature
- Low noise level
- High resistance to vibrations
- Thermally expandable mounting feet (CAR type)
- Optional thermal switch or PT100 element for thermal protection
- 300mm lead with sleeve or terminal connection up to 10 mm2
- Customizable for customer needs and applications (available OEM versions)
CBH / CBV / CBR wired connected IP54, with thermal switch
Type | Pn [W] at 40°C | Max Temp °C | R [Ω] min-max | Impulse Load [W] Temp, Ambient 40°C, cycle 120s | |||
---|---|---|---|---|---|---|---|
1-second Duty Cycle | 5-second Duty Cycle | 10-second Duty Cycle | 40-second Duty Cycle | ||||
CBH / CBV 190 xT | 85 | 210 | 0.5 - 1000 | 5 | 1.4 | 0.9 | 0.3 |
CBH / CBV 240 xT | 120 | 215 | 0.8 - 1500 | 9.8 | 2.5 | 1.5 | 0.4 |
CBH / CBV 290 xT | 150 | 220 | 1.5 - 2000 | 16.6 | 3.8 | 1.9 | 0.5 |
CBH / CBV 360 xT | 200 | 225 | 1.8 - 2000 | 25.6 | 5.2 | 2.6 | 0.7 |
CBH / CBV 430 xT | 250 | 230 | 2.0 - 2000 | 32.5 | 6.5 | 3.2 | 0.8 |
CBR-V/H 160xT | 160 | 210 | 0.5 - 1000 | 5.4 | 1.5 | 1 | 0.5 |
CBR-V / H 210xT | 230 | 210 | 0.8 - 1500 | 10.6 | 2.8 | 1.8 | 0.9 |
CBR-V / H 260 xT | 300 | 225 | 1.5 - 2000 | 18.4 | 4.6 | 2.8 | 1.3 |
CBR-V / H 330 xT | 390 | 230 | 1.8 - 2000 | 30 | 7.1 | 4.2 | 1.7 |
CBR-V / H 400 xT | 490 | 230 | 2.0 - 2000 | 38.8 | 11.4 | 6.8 | 2.1 |
CBR-V / H 460 XT | 740 | 240 | 2.4 - 2000 | 39.4 | 12.9 | 8 | 2.4 |
CBR-V / H 560 XT | 920 | 250 | 3.0 - 2000 | 49.4 | 16.2 | 10 | 3.1 |
CBR-V / H 660 XT | 1110 | 260 | 3.5 - 2000 | 60.6 | 19.7 | 12.1 | 3.8 |
CBR-V / H 760 XT | 1290 | 260 | 4.0 - 2000 | 73.8 | 23.3 | 14.2 | 4.3 |
CBRK 1000V Wired Connected IP54 without Thermal Switch
Type | Pn [W] at 40°C | Max Temp °C | R [Ω] min-max | Impulse Load [W] Temp, Ambient 40°C, cycle 120s | |||
---|---|---|---|---|---|---|---|
1-second Duty Cycle | 5-second Duty Cycle | 10-second Duty Cycle | 40-second Duty Cycle | ||||
CBRK 125 С | 135 | 210 | 0.5 - 1000 | 5.4 | 1.5 | 1 | 0.5 |
CBRK 175 С | 210 | 210 | 0.8 - 1500 | 10.6 | 2.8 | 1.8 | 0.9 |
CBRK 225 С | 280 | 225 | 1.5 - 2000 | 18.4 | 4.6 | 2.8 | 1.3 |
CBRK 295 С | 400 | 230 | 1.8 - 2000 | 30 | 7.1 | 4.2 | 1.7 |
CBRK 365 С | 500 | 230 | 2.0 - 2000 | 38.8 | 11.4 | 6.8 | 2.1 |
CBRK 426 С | 650 | 240 | 2.4 - 2000 | 39.4 | 12.9 | 8 | 2.4 |
CBRK 526 С | 800 | 250 | 3.0 - 2000 | 49.4 | 16.2 | 10 | 3.1 |
CBRK 626 С | 1000 | 260 | 3.5 - 2000 | 60.6 | 19.7 | 12.1 | 3.8 |
CBRK 726 С | 1200 | 260 | 4.0 - 2000 | 73.8 | 23.3 | 14.2 | 4.3 |
CBRK 1000V with Thermal Switch, Wired Connected or Through Terminal Box, IP54
Type | Pn [W] at 40°C | Max Temp °C | R [Ω] min-max | Impulse Load [W] Temp, Ambient 40°C, cycle 120s | |||
---|---|---|---|---|---|---|---|
1-second Duty Cycle | 5-second Duty Cycle | 10-second Duty Cycle | 40-second Duty Cycle | ||||
CBRK 160xT | 180 | 210 | 0.5 - 1000 | 5.4 | 1.5 | 1 | 0.5 |
CBRK 210xT | 250 | 210 | 0.8 - 1500 | 10.6 | 2.8 | 1.8 | 0.9 |
CBRK 260 xT | 330 | 225 | 1.5 - 2000 | 18.4 | 4.6 | 2.8 | 1.3 |
CBRK 330 xT | 440 | 230 | 1.8 - 2000 | 30 | 7.1 | 4.2 | 1.7 |
CBRK 400 xT | 540 | 230 | 2.0 - 2000 | 38.8 | 11.4 | 6.8 | 2.1 |
CBRK 460 xT | 610 | 240 | 2.4 - 2000 | 39.4 | 12.9 | 8 | 2.4 |
CBRK 560 xT | 780 | 250 | 3.0 - 2000 | 49.4 | 16.2 | 10 | 3.1 |
CBRK 660 xT | 950 | 260 | 3.5 - 2000 | 60.6 | 19.7 | 12.1 | 3.8 |
CBRK 760 xT | 1100 | 260 | 4.0 - 2000 | 73.8 | 23.3 | 14.2 | 4.3 |
*The ranges of impulses for short pulses depend on the resistance values. Resistors with lower resistance values have more conductive material than resistors with higher resistance values. The ranges in this table refer to resistors around 40R.
Temperature coefficient | 100 ppm/K | |
---|---|---|
Dielectric strength | 3500 VAC for 1 minute | |
Insulation resistance | > 20MΩ / case | |
Overload for one-second pulse per hour | 10 - 100 x (depending on the resistor) | |
Overload for five-second pulse per hour | 4 - 25 x (depending on the resistor) | |
Environment | - 40 °C / +70 °C | |
Value loss, wirewound version | Linear: 40°C = Pn to 70°C = 0.85 * Pn | |
Value loss, TW 200°C version | Linear: 40°C = Pn to 70°C = 0.65 * Pn | |
Value loss, vertical mounting | No loss | |
Value loss, horizontal mounting | 0.8 * Pn | |
Value loss at high altitudes | 1000m | No loss |
1500m | 0.94 * Pn | |
3000m | 0.82 * Pn | |
Mounting instructions | It is recommended to maintain a distance of 200mm to the nearest element to prevent neighboring elements from overheating. | |
If two or more brake resistors are mounted next to each other, a distance of 400mm between them should be maintained. If closer, the rated power should be reduced. | ||
Cooling | The rated power of the resistors refers to passive, air-cooled conditions. | |
Vibrations | According to EN 60068-2-6Frequency range 1-100HzAcceleration/amplitude | |
1 - 13 Hz | ± 1mm | |
13 - 100 Hz | at ± 0.7G | |
Corrosion resistance | According to IEC 60721-3-3/3K3 (C2 medium)200h cyclic salt mist IEC60068-2-52 | |
Connection recommendations | To minimize EMC interference, the use of screens, especially with any PWM, is recommended. | |
Resistance tolerance | 10% (optional 5%) | |
Operating voltage | Standard | UL: 600VAC / 850VDC ; IEC: 690VAC /975VDC |
On request | 1000VAC / 1400VDC | |
Resistor heating time constant | 1000s | |
Thermal switch (optional) | Thermal switch | 130 / 160 / 180 / 200 °C. 2A. 250 VACNC |
Minimum voltage | 2V | |
Minimum current | 10mA | |
Rated current/voltage | 2.5A @ 250VAC cos ʕ=1 | |
Dielectric voltage | 2000VAC (3500VAC between TS and R) | |
Temperature requirements for cables | IP 21 | 80°C |
IP 65 | 90°C |
Send an inquiry
Are you interested in this product? Do you need additional information or individual pricing?
Contact us
Type | Pn [W] at 40°C | Max Temp °C | R [Ω] min-max | Impulse Load [W] Temp, Ambient 40°C, cycle 120s | |||
---|---|---|---|---|---|---|---|
1-second Duty Cycle | 5-second Duty Cycle | 10-second Duty Cycle | 40-second Duty Cycle | ||||
СВН/ CBV 165 С | 110 | 265 | 0.5 - 1000 | 5 | 1.4 | 0.9 | 0.3 |
СВН/ CBV 215 С | 155 | 270 | 0.8 - 1500 | 9.8 | 2.5 | 1.6 | 0.5 |
СВН/ CBV 265 С | 200 | 270 | 1.5 - 2000 | 16.6 | 4 | 2.4 | 0.6 |
СВН/ CBV 335 С | 270 | 280 | 1.8 - 2000 | 26.6 | 6.2 | 3.4 | 0.9 |
СВН/ CBV 405 С | 330 | 285 | 2.0 - 2000 | 34.1 | 8.5 | 4.3 | 1 |
CBR-V/H175 С | 311 | 265 | 0.8 - 1500 | 10.5 | 2.7 | 1.8 | 0.9 |
CBR-V/ Н 225 С | 400 | 270 | 1.5 - 2000 | 18.3 | 4.5 | 2.8 | 1.2 |
CBR-V/ Н 295 С | 525 | 275 | 1.8 - 2000 | 29.7 | 7.1 | 4.2 | 1.8 |
CBR-V/ Н 365 С | 650 | 280 | 2.0 - 2000 | 38.4 | 11.3 | 6.7 | 2.4 |
CBR-V/ Н 426 С | 980 | 285 | 2.4 - 2000 | 39.1 | 12.9 | 7.9 | 2.9 |
CBR-V/ Н 526 С | 1220 | 295 | 3.0 - 2000 | 49.1 | 16.1 | 9.9 | 3.6 |
CBR-V/ Н 626 С | 1460 | 305 | 3.5 - 2000 | 60.6 | 19.7 | 12 | 4.4 |
CBR-V/ Н 726 С | 1700 | 310 | 4.0 - 2000 | 73.1 | 23.4 | 14.3 | 5.2 |
СВН/ CBV 165 С | 110 | 265 | 0.5 - 1000 | 5 | 1.4 | 0.9 | 0.3 |
Construction and Main Characteristics
- Approved by UL
- Compact dimensions
- Nominal power range from 110W to 1700W
- Energy levels from 9kJ to 150kJ (5-second duty cycle, cycle 120s), depending on resistance value
- Aluminum housing for high IP rating
- IP50-IP65
- Internal wire spirals wound on ceramics for lower resistance
- Nickel-chromium alloy 8020 for low thermal drift
- Mica insulation for high dielectric strength
- Filled with Al2O3 or SiO2 for high thermal capacity/overload capability
- Low surface temperature
- Low noise level
- High resistance to vibrations
- Thermally expandable mounting feet (CAR type)
- Optional thermal switch or PT100 element for thermal protection
- 300mm lead with sleeve or terminal connection up to 10 mm2
- Customizable for customer needs and applications (available OEM versions)
CBH / CBV / CBR wired connected IP54, with thermal switch
Type | Pn [W] at 40°C | Max Temp °C | R [Ω] min-max | Impulse Load [W] Temp, Ambient 40°C, cycle 120s | |||
---|---|---|---|---|---|---|---|
1-second Duty Cycle | 5-second Duty Cycle | 10-second Duty Cycle | 40-second Duty Cycle | ||||
CBH / CBV 190 xT | 85 | 210 | 0.5 - 1000 | 5 | 1.4 | 0.9 | 0.3 |
CBH / CBV 240 xT | 120 | 215 | 0.8 - 1500 | 9.8 | 2.5 | 1.5 | 0.4 |
CBH / CBV 290 xT | 150 | 220 | 1.5 - 2000 | 16.6 | 3.8 | 1.9 | 0.5 |
CBH / CBV 360 xT | 200 | 225 | 1.8 - 2000 | 25.6 | 5.2 | 2.6 | 0.7 |
CBH / CBV 430 xT | 250 | 230 | 2.0 - 2000 | 32.5 | 6.5 | 3.2 | 0.8 |
CBR-V/H 160xT | 160 | 210 | 0.5 - 1000 | 5.4 | 1.5 | 1 | 0.5 |
CBR-V / H 210xT | 230 | 210 | 0.8 - 1500 | 10.6 | 2.8 | 1.8 | 0.9 |
CBR-V / H 260 xT | 300 | 225 | 1.5 - 2000 | 18.4 | 4.6 | 2.8 | 1.3 |
CBR-V / H 330 xT | 390 | 230 | 1.8 - 2000 | 30 | 7.1 | 4.2 | 1.7 |
CBR-V / H 400 xT | 490 | 230 | 2.0 - 2000 | 38.8 | 11.4 | 6.8 | 2.1 |
CBR-V / H 460 XT | 740 | 240 | 2.4 - 2000 | 39.4 | 12.9 | 8 | 2.4 |
CBR-V / H 560 XT | 920 | 250 | 3.0 - 2000 | 49.4 | 16.2 | 10 | 3.1 |
CBR-V / H 660 XT | 1110 | 260 | 3.5 - 2000 | 60.6 | 19.7 | 12.1 | 3.8 |
CBR-V / H 760 XT | 1290 | 260 | 4.0 - 2000 | 73.8 | 23.3 | 14.2 | 4.3 |
CBRK 1000V Wired Connected IP54 without Thermal Switch
Type | Pn [W] at 40°C | Max Temp °C | R [Ω] min-max | Impulse Load [W] Temp, Ambient 40°C, cycle 120s | |||
---|---|---|---|---|---|---|---|
1-second Duty Cycle | 5-second Duty Cycle | 10-second Duty Cycle | 40-second Duty Cycle | ||||
CBRK 125 С | 135 | 210 | 0.5 - 1000 | 5.4 | 1.5 | 1 | 0.5 |
CBRK 175 С | 210 | 210 | 0.8 - 1500 | 10.6 | 2.8 | 1.8 | 0.9 |
CBRK 225 С | 280 | 225 | 1.5 - 2000 | 18.4 | 4.6 | 2.8 | 1.3 |
CBRK 295 С | 400 | 230 | 1.8 - 2000 | 30 | 7.1 | 4.2 | 1.7 |
CBRK 365 С | 500 | 230 | 2.0 - 2000 | 38.8 | 11.4 | 6.8 | 2.1 |
CBRK 426 С | 650 | 240 | 2.4 - 2000 | 39.4 | 12.9 | 8 | 2.4 |
CBRK 526 С | 800 | 250 | 3.0 - 2000 | 49.4 | 16.2 | 10 | 3.1 |
CBRK 626 С | 1000 | 260 | 3.5 - 2000 | 60.6 | 19.7 | 12.1 | 3.8 |
CBRK 726 С | 1200 | 260 | 4.0 - 2000 | 73.8 | 23.3 | 14.2 | 4.3 |
CBRK 1000V with Thermal Switch, Wired Connected or Through Terminal Box, IP54
Type | Pn [W] at 40°C | Max Temp °C | R [Ω] min-max | Impulse Load [W] Temp, Ambient 40°C, cycle 120s | |||
---|---|---|---|---|---|---|---|
1-second Duty Cycle | 5-second Duty Cycle | 10-second Duty Cycle | 40-second Duty Cycle | ||||
CBRK 160xT | 180 | 210 | 0.5 - 1000 | 5.4 | 1.5 | 1 | 0.5 |
CBRK 210xT | 250 | 210 | 0.8 - 1500 | 10.6 | 2.8 | 1.8 | 0.9 |
CBRK 260 xT | 330 | 225 | 1.5 - 2000 | 18.4 | 4.6 | 2.8 | 1.3 |
CBRK 330 xT | 440 | 230 | 1.8 - 2000 | 30 | 7.1 | 4.2 | 1.7 |
CBRK 400 xT | 540 | 230 | 2.0 - 2000 | 38.8 | 11.4 | 6.8 | 2.1 |
CBRK 460 xT | 610 | 240 | 2.4 - 2000 | 39.4 | 12.9 | 8 | 2.4 |
CBRK 560 xT | 780 | 250 | 3.0 - 2000 | 49.4 | 16.2 | 10 | 3.1 |
CBRK 660 xT | 950 | 260 | 3.5 - 2000 | 60.6 | 19.7 | 12.1 | 3.8 |
CBRK 760 xT | 1100 | 260 | 4.0 - 2000 | 73.8 | 23.3 | 14.2 | 4.3 |
*The ranges of impulses for short pulses depend on the resistance values. Resistors with lower resistance values have more conductive material than resistors with higher resistance values. The ranges in this table refer to resistors around 40R.
Temperature coefficient | 100 ppm/K | |
---|---|---|
Dielectric strength | 3500 VAC for 1 minute | |
Insulation resistance | > 20MΩ / case | |
Overload for one-second pulse per hour | 10 - 100 x (depending on the resistor) | |
Overload for five-second pulse per hour | 4 - 25 x (depending on the resistor) | |
Environment | - 40 °C / +70 °C | |
Value loss, wirewound version | Linear: 40°C = Pn to 70°C = 0.85 * Pn | |
Value loss, TW 200°C version | Linear: 40°C = Pn to 70°C = 0.65 * Pn | |
Value loss, vertical mounting | No loss | |
Value loss, horizontal mounting | 0.8 * Pn | |
Value loss at high altitudes | 1000m | No loss |
1500m | 0.94 * Pn | |
3000m | 0.82 * Pn | |
Mounting instructions | It is recommended to maintain a distance of 200mm to the nearest element to prevent neighboring elements from overheating. | |
If two or more brake resistors are mounted next to each other, a distance of 400mm between them should be maintained. If closer, the rated power should be reduced. | ||
Cooling | The rated power of the resistors refers to passive, air-cooled conditions. | |
Vibrations | According to EN 60068-2-6Frequency range 1-100HzAcceleration/amplitude | |
1 - 13 Hz | ± 1mm | |
13 - 100 Hz | at ± 0.7G | |
Corrosion resistance | According to IEC 60721-3-3/3K3 (C2 medium)200h cyclic salt mist IEC60068-2-52 | |
Connection recommendations | To minimize EMC interference, the use of screens, especially with any PWM, is recommended. | |
Resistance tolerance | 10% (optional 5%) | |
Operating voltage | Standard | UL: 600VAC / 850VDC ; IEC: 690VAC /975VDC |
On request | 1000VAC / 1400VDC | |
Resistor heating time constant | 1000s | |
Thermal switch (optional) | Thermal switch | 130 / 160 / 180 / 200 °C. 2A. 250 VACNC |
Minimum voltage | 2V | |
Minimum current | 10mA | |
Rated current/voltage | 2.5A @ 250VAC cos ʕ=1 | |
Dielectric voltage | 2000VAC (3500VAC between TS and R) | |
Temperature requirements for cables | IP 21 | 80°C |
IP 65 | 90°C |
Your review appreciation cannot be sent