-
BackX
-
Components
-
-
Category
-
Semiconductors
- Diodes
- Thyristors
-
Electro-insulated Modules
- Electro-insulated Modules | VISHAY (IR)
- Electro-insulated Modules | INFINEON (EUPEC)
- Electro-insulated Modules | Semikron
- Electro-insulated Modules | POWEREX
- Electro-insulated Modules | IXYS
- Electro-insulated Modules | POSEICO
- Electro-insulated Modules | ABB
- Electro-insulated Modules | TECHSEM
- Go to the subcategory
- Bridge Rectifiers
-
Transistors
- Transistors | GeneSiC
- SiC MOSFET Modules | Mitsubishi
- SiC MOSFET Modules | STARPOWER
- Module SiC MOSFET ABB’s
- IGBT Modules | MITSUBISHI
- Transistor Modules | MITSUBISHI
- MOSFET Modules | MITSUBISHI
- Transistor Modules | ABB
- IGBT Modules | POWEREX
- IGBT Modules | INFINEON (EUPEC)
- Silicon Carbide (SiC) semiconductor elements
- Go to the subcategory
- Gate Drivers
- Power Blocks
- Go to the subcategory
-
Electrical Transducers
-
Current Transducers | LEM
- Closed-Loop Current Transducers (C/L)
- Open-Loop Current Transducers (O/L)
- Current Transducers supplied with unipolar voltage
- 'Eta' Current Transducers
- Current Transducers - LF xx10 Series
- Current Transducers - LH Series
- Current Transducer - HOYL and HOYS Series
- Current Transducers - GO–SME & GO–SMS Series
- AUTOMOTIVE current transducers
- Go to the subcategory
-
Voltage Transducers | LEM
- Voltage Transducers - LV Series
- Voltage Transducers - DVL Series
- Precision Voltage Transducers with double magnetic core - CV Series
- Voltage Transducer for Traction - DV 4200/SP4
- Voltage Transducers - DVM Series
- Voltage Transducer - DVC 1000-P
- Voltage Transducers - DVC 1000 Series
- Go to the subcategory
- Precision Current Transducers | LEM
- Go to the subcategory
-
Current Transducers | LEM
-
Passive components (capacitors, resistors, fuses, filters)
- Resistors
-
Fuses
- Miniature Fuses for electronic circuits - ABC & AGC Series
- Tubular Fast-acting Fuses
- Time-delay Fuse Links with GL/GG & AM characteristics
- Ultrafast Fuse Links
- Fast-acting Fuses (British & American standard)
- Fast-acting Fuses (European standard)
- Traction Fuses
- High-voltage Fuse Links
- Go to the subcategory
- Capacitors
- EMI Filters
- Supercapacitors
- Power surge protection
- Go to the subcategory
-
Relays and Contactors
- Relays and Contactors - Theory
- 3-Phase AC Semiconductor Relays
- DC Semiconductor Relays
- Controllers, Control Systems and Accessories
- Soft Starters and Reversible Relays
- Electromechanical Relays
- Contactors
- Rotary Switches
-
Single-Phase AC Semiconductor Relays
- AC ONE PHASE RELAYS 1 series| D2425 | D2450
- One phase semiconductor AC relays CWA and CWD series
- One phase semiconductor AC relays CMRA and CMRD series
- One phase semiconductor AC relays - PS series
- Double and quadruple semiconductor AC relays - D24 D, TD24 Q, H12D48 D series
- One phase semiconductor relays - gn series
- Ckr series single phase solid state relays
- One phase AC semiconductor relays for DIN bus - ERDA I ERAA series
- 150A AC single phase relays
- Rail Mountable Solid State Relays With Integrated Heat Sink - ENDA, ERDA1 / ERAA1 series
- Go to the subcategory
- Single-Phase AC Semiconductor Relays for PCBs
- Interface Relays
- Go to the subcategory
- Cores and Other Inductive Components
- Heatsinks, Varistors, Thermal Protection
- Fans
- Air Conditioning, Accessories for Electrical Cabinets, Coolers
-
Batteries, Chargers, Buffer Power Supplies and Inverters
- Batteries, Chargers - Theoretical Description
- Modular Li-ion Battery Building Blocks, Custom Batteries, BMS
- Batteries
- Battery Chargers and Accessories
- Uninterruptible Power Supply and Buffer Power Supplies
- Inverters and Photovoltaic Equipments
- Energy storage
- Fuel cells
- Lithium-ion batteries
- Go to the subcategory
-
Automatics
- Futaba Drone Parts
- Limit Switches, Microswitches
- Sensors, Transducers
-
Infrared Thermometers (Pyrometers)
- IR-TE Series - Water-proof Palm-sized Radiation Thermometer
- IR-TA Series - Handheld Type Radiation Thermometer
- IR-H Series - Handheld Type Radiation Thermometer
- IR-BA Series - High-speed Compact Radiation Thermometer
- IR-FA Series - Fiber Optic Radiation Thermometer
- IR-BZ Series - Compact Infrared Thermometers
- Go to the subcategory
- Counters, Time Relays, Panel Meters
- Industrial Protection Devices
- Light and Sound Signalling
- Thermographic Camera
- LED Displays
- Control Equipments
-
Recorders
- Hybrid Recorders - AL3000 Series | CHINO
- Graphic Recorder - KR2000 Series | CHINO
- Ubiquitous Recorders - KR5000 Series | CHINO
- Palm-sized Temperature/Humidity Meters - HN-CH Series | CHINO
- Consumables for Recorders
- 71VR1 - Compact Paperless Recorder | M-SYSTEM
- Graphic Recorder - KR3000 Series | CHINO
- PC Recorders - R1M Series | M-SYSTEM
- PC Recorders - R2M Series | M-SYSTEM
- PC Recorders - RZMS Series | M-SYSTEM
- PC Recorders - RZUS Series | M-SYSTEM
- Go to the subcategory
- Go to the subcategory
-
Cables, Litz wires, Conduits, Flexible connections
- Wires
- Litz wires
- Cables for extreme applications
- Sleevings
-
Braids
- Flat Braids
- Round Braids
- Very Flexible Flat Braids
- Very Flexible Round Braids
- Cylindrical Cooper Braids
- Cylindrical Cooper Braids and Sleevings
- Flexible Earthing Connections
- Galvanized and Stainless Steel Cylindrical Braids
- PCV Insulated Copper Braids (temp. up to 85C)
- Flat Aluminium Braids
- Junction Set - Braids and Tubes
- Go to the subcategory
- Traction Equipment
- Cable Terminals
- Flexible Insulated Busbars
- Flexible Multilayer Busbars
- Cable Duct Systems
- Hoses
- Go to the subcategory
- View all categories
-
Semiconductors
-
-
- Suppliers
-
Applications
- CNC Machine Tools
- DC and AC Drives (Inverters)
- Energetics
- Energy bank
- Equipment and Components for Hazardous Areas [Ex]
- Equipment for Distribution, Control and Telecommunications Cabinets
- HVAC Automation
- Induction Heating
- Industrial Automation
- Industrial Protective Devices
- Machines for Drying and Wood Processing
- Machines for Thermoforming Plastics
- Mining, Metallurgy and Foundry
- Motors and Transformers
- Power Supplies (UPS) and Rectifier Systems
- Printing
- Temperature Measurement and Regulation
- Test and Laboratory Measurements
- Tram and Railway Traction
- Welding Machines
-
Assembly
-
-
Montaż urządzeń
- Assembly of equipment on request
- Designing and Assembling of Busbar Cabinets, Switching Cabinets, Power Cabinets
- Power systems installation
- Components
- Machines built for order
- R&D research and development work
-
Industrial Testers
- Tester for diodes and thyristors measurement
- Thermal and motor circuit breakers testing stand
- Varistors and surge protectors testers
- Car fuses testing stand
- Tester for the power diode and thyristor reverse recovery charge Qrr measurement
- Rotor tester FD series
- Circuit breakers tester
- Tester for calibrating relays
- Video inspection tester for gas spring piston rods
- High-current thyristor switch
- Mesh ripping tester
- Go to the subcategory
- View all categories
-
-
-
Inductors
-
-
Modernizacja induktorów
- Repair of used inductors
- Modernization of inductors
-
Production of new inductors
- Inductors for crankshaft hardening
- Hardening of band saw teeth
- Inductors for heating elements before gluing
- Hardening of raceways of automotive wheel hub bearings
- Hardening of the drive transmission components
- Hardening of stepped shafts
- Heating in contraction joints
- Induction for scanning hardening
- Soft soldering
- Billet heaters
- Go to the subcategory
- Knowledge base
- View all categories
-
-
-
Induction devices
-
-
Urządzenia indukcyjne
-
Induction heating generators
-
Induction Heating Products Ambrell
- Generators power 500 W, frequency 150 - 400 kHz
- Generators power 1.2 - 2.4 kW, frequency 150 - 400 kHz
- Generators power 4.2 - 10 kW, frequency 150 - 400 kHz
- Generators power 10-15 kW, frequency 50-150 kHz
- Generators power 30-45 kW, frequency 50-150 kHz
- Generators power 65-135 kW, frequency 50-150 kHz
- Generators power 180-270 kW, frequency 50-150 kHz
- Generators power 20-35-50 kW, frequency 15-45 kHz
- Generators power 75-150 kW, frequency 15-45 kHz
- Generators power 200-500 kW, frequency 15-45 kHz
- Generators power 20-50 kW, frequency 5-15 kHz
- Go to the subcategory
- Induction heating products Denki Kogyo
-
JKZ induction heating generators
- Generators CX, frequency: 50-120kHz, power: 5-25kW
- Generators SWS, frequency: 15-30kHz, power: 25-260kW
- Molding and forging furnaces MFS, frequency: 0,5-10kHz, power: 80-500kW
- Melting metals furnaces MFS, frequency: 0,5-10kHz, power: 70-200kW
- Generators UHT, frequency: 200-400kHz, power: 10-160kW
- Go to the subcategory
- Lamp generators for induction heating
- Induction Heating Products - Himmelwerk
- Go to the subcategory
-
Induction Heating Products Ambrell
- Repairs and modernization
- Peripherals
-
Applications
- Medical Applications with Precision Induction Heating
- Applications for automotive industry
- Soldering
- Brazing
- Aluminum Brazing
- Brazing a magnetic steel cutting tool
- Pin Sealing
- Atmospheric Brazing
- Soldering brass and steel radiator caps
- Carbide Tipping
- Soldering a copper lug and a wire
- Go to the subcategory
- Knowledge base
- View all categories
-
Induction heating generators
-
-
-
Service
-
-
asd
- Service of industrial water coolers and air conditioners
- Machines Repairs and Modernizations
- Repair and Maintenance of Power Electronics, Electronic and Industrial Automation Devices
- HV Power Supplies for Electrostatic Precipitators
- Industrial Printers and Labelling Machines
- Certificates / Entitlements
- View all categories
-
-
- Contact
- Zobacz wszystkie kategorie
Photos are for informational purposes only. View product specification
please use latin characters
Type | Resistance Range R [Ω] min-max | Rated Power for Initial Temperature and Temperature Change T, Hottest Spot Temperature on Surface 190°C | ||||||||
---|---|---|---|---|---|---|---|---|---|---|
Input Temperature 20°C | Input Temperature 40°C | Input Temperature 50°C | ||||||||
10 | 20 | 40 | 10 | 20 | 40 | 10 | 20 | 40 | ||
CBW 180 | 0,04- 13 | 1200 | 1150 | 1050 | 1050 | 1000 | 930 | 960 | 930 | 860 |
CBW 210 | 0,05 - 2000 | 1650 | 1600 | 1500 | 1450 | 1400 | 1300 | 1350 | 1300 | 1200 |
CBW 260 | 0,07 – 2000, | 2350 | 2300 | 2150 | 2050 | 2000 | 1850 | 1950 | 1850 | 1700 |
CBW 330 | 0,09 - 2000 | 2950 | 2850 | 2700 | 2600 | 2500 | 2300 | 2400 | 2300 | 2150 |
CBW 400 | 0,11 - 2000 | 3550 | 3450 | 3200 | 3100 | 3000 | 2800 | 2900 | 2800 | 2550 |
CBW 460 | 0,14 - 2000 | 4100 | 4000 | 3750 | 3600 | 3500 | 3250 | 3400 | 3250 | 3000 |
CBW 560 | 0,18- 110 | 4950 | 4800 | 4500 | 4350 | 4200 | 3900 | 4050 | 3900 | 3600 |
CBW 660 | 0,22- 130 | 5900 | 5700 | 5350 | 5200 | 5000 | 4650 | 4800 | 4650 | 4300 |
CBW 760 | 0,27- 150 | 6700 | 6500 | 6100 | 5900 | 5700 | 5300 | 5500 | 5300 | 4900 |
CBW 860 | 0,31 - 180 | 7650 | 7450 | 6950 | 6750 | 6500 | 6050 | 6250 | 6050 | 5550 |
CBW 960 | 0,35 - 220 | 8500 | 8250 | 7700 | 7450 | 7200 | 6700 | 6950 | 6700 | 6150 |
Construction and Key Properties
- Compact dimensions
- Nominal power range 1200W – 8500W
- Energy levels from 27kJ – 675kJ (5s pulse, 120s cycle), depending on resistance value
- Aluminum housing for high IP rating
- IP50-IP65
- Internal wire spirals wound on ceramics for lower resistance
- Internal components of wire spirals wound on mica for lower resistance
- Nickel-chromium alloy 8020 for low thermal drift
- Mica insulation for high dielectric strength
- Filling of Al2O3 or SiO2 for high thermal capacity/high overload capability
- Low surface temperature
- Low noise level
- High vibration resistance
- Thermally expansive mounting feet (CAR type)
- Optional thermal switch or PT100 element for thermal protection
- 300mm wire with sleeve or box connection up to 10 mm2
- Multi-element housings (from 2 to 3)
- Customizable to customer needs and applications (available OEM versions)
CBW resistors are used in wind turbines as filtering resistors and on board medium-power traction systems, such as trams - as braking resistors. In some tram systems, recovered power is used for heating the interior of the tram on cold days.
Maximum Dissipated Power
The maximum continuous power depends absolutely on the incoming water temperature and the temperature increase of the water, which is directly dependent on the water flow. Table 3 shows the maximum continuous power at a given water flow and different ΔT.
Flow Rate L/h | ∆T Water | ∆T Water/Glycol 60/40 | ||||||||
---|---|---|---|---|---|---|---|---|---|---|
10 | 15 | 20 | 25 | 30 | 10 | 15 | 20 | 25 | 30 | |
7 kW | 710 | 470 | 350 | 280 | 240 | 1070 | 710 | 530 | 420 | 360 |
6 kW | 610 | 400 | 300 | 240 | 200 | 920 | 600 | 450 | 360 | 300 |
5 kW | 510 | 340 | 250 | 200 | 170 | 770 | 510 | 380 | 300 | 260 |
4 kW | 400 | 270 | 200 | 160 | 130 | 600 | 410 | 300 | 240 | 200 |
3 kW | 300 | 200 | 150 | 120 | 100 | 450 | 300 | 230 | 180 | 150 |
2 kW | 200 | 130 | 100 | 80 | 70 | 300 | 200 | 150 | 120 | 110 |
1 kW | 100 | 65 | 50 | 40 | 35 | 150 | 100 | 80 | 60 | 50 |
Pressure Drop
The pressure drop strongly depends on the used nozzles. Many customers use their own nozzles, which makes it difficult to provide standard values. For CBW460 resistor with SW22x45.5 and a flow rate of 120 l/h, the pressure drop is 55 mBar per channel, 110 mBar in total, for two cooling tubes included.
Temperature Coefficient | 100 ppm/K | |
---|---|---|
Dielectric Strength | 3500 VAC at 1 minute | |
Insulation Resistance | > 20MΩ / housing | |
Overload at One-second Pulse per Hour | 70 - 250 x (depending on the resistor) | |
Overload at Five-second Pulse per Hour | 20 - 60 x (depending on the resistor) | |
Environment | - 40 °C / +70 °C | |
Value Loss for Wirewound Version | Linear: 40°C = Pn to 70°C = 0.85 * Pn | |
Value Loss for TW 200°C Version | Linear: 40°C = Pn to 70°C = 0.65 * Pn | |
Value Loss for Vertical Mounting | No loss | |
Value Loss for Horizontal Mounting | 0.8 * Pn | |
Value Loss at High Altitudes | 1000m | No loss |
1500m | 0.94 * Pn | |
3000m | 0.82 * Pn | |
Mounting Instructions | It is recommended to keep a distance of 200mm to the nearest element to prevent heating of neighboring components. | |
If two or more inhibitory resistors are mounted next to each other, a distance of 400mm between them should be maintained. If closer, reduce the rated power. | ||
Cooling | The rated power of the resistors applies to passive, air cooling conditions. | |
Vibrations | According to EN 60068-2-6 Frequency Range 1-100Hz Acceleration/Amplitude | |
1 - 13 Hz | ± 1mm | |
13 - 100 Hz | at ± 0.7G | |
Corrosion Resistance | According to IEC 60721-3-3/3K3 (C2 medium) 200h cyclic salt mist IEC60068-2-52 | |
Connection Recommendations | To minimize EMC interference, the use of screens, especially with any PWM, is recommended. | |
Resistance Tolerance | 10% (optionally 5%) | |
Operating Voltage | Can Version | UL: 600VAC / 850VDC; IEC: 690VAC /975VDC |
Wirewound Version | 1000VAC / 1400VDC | |
Resistor Heating Time Constant | 1000-3000s | |
Thermal Switch (optional) | Thermal Switch | 130 / 160 / 180 / 200 °C, 2A, 250 VAC NC |
Minimum Voltage | 2V | |
Minimum Current | 10mA | |
Rated Current/Voltage | 2.5A @ 250VAC cos ʕ=1 | |
Dielectric Voltage | 2000VAC (3500VAC between TS and R) | |
Temperature Requirements for Cables | IP 21 | 80°C |
IP 65 | 90°C |
Applications
CBW power resistors are used in solutions where large power pulses or high average power are present. The resistive elements are immersed in sand. This serves as a high thermal capacity, capable of absorbing large energy pulses. Energy is conducted through the sand and absorbed by the water. Approximately 90% of the total dissipation will be captured by the water, while the remaining portion is emitted into the air. It is also possible to insulate the aluminum housing, thereby promoting the dispersion of almost the entire energy into the water.
CBW resistors are employed in wind turbines as filtering resistors and in medium-power traction vehicles such as trams, where they function as braking resistors. In certain tram systems, the recovered power is utilized to heat the interior of the tram during cold days.
Maximum Distributed Power
The maximum continuous power is absolutely dependent on the incoming water temperature and the increase in water temperature, which is directly linked to water flow rate. Table 3 displays the maximum continuous power at a given water flow rate and varying ΔT.
Flow Rate L/h | ∆ T Water | ∆ T Water/Glycol 60/40 | ||||||||
---|---|---|---|---|---|---|---|---|---|---|
10 | 15 | 20 | 25 | 30 | 10 | 15 | 20 | 25 | 30 | |
7 kW | 710 | 470 | 350 | 280 | 240 | 1070 | 710 | 530 | 420 | 360 |
6 kW | 610 | 400 | 300 | 240 | 200 | 920 | 600 | 450 | 360 | 300 |
5 kW | 510 | 340 | 250 | 200 | 170 | 770 | 510 | 380 | 300 | 260 |
4 kW | 400 | 270 | 200 | 160 | 130 | 600 | 410 | 300 | 240 | 200 |
3 kW | 300 | 200 | 150 | 120 | 100 | 450 | 300 | 230 | 180 | 150 |
2 kW | 200 | 130 | 100 | 80 | 70 | 300 | 200 | 150 | 120 | 110 |
1 kW | 100 | 65 | 50 | 40 | 35 | 150 | 100 | 80 | 60 | 50 |
Pressure Drop
The pressure drop strongly depends on the used nozzles. Many customers use their own nozzles, which makes it difficult to provide standard values. For the CBW460 resistor with SW22x45.5 and a flow rate of 120 l/h, the pressure drop is 55 mBar per channel, 110 mBar in total, for two cooling tubes in the set.
Send an inquiry
Are you interested in this product? Do you need additional information or individual pricing?
Contact us
Type | Resistance Range R [Ω] min-max | Rated Power for Initial Temperature and Temperature Change T, Hottest Spot Temperature on Surface 190°C | ||||||||
---|---|---|---|---|---|---|---|---|---|---|
Input Temperature 20°C | Input Temperature 40°C | Input Temperature 50°C | ||||||||
10 | 20 | 40 | 10 | 20 | 40 | 10 | 20 | 40 | ||
CBW 180 | 0,04- 13 | 1200 | 1150 | 1050 | 1050 | 1000 | 930 | 960 | 930 | 860 |
CBW 210 | 0,05 - 2000 | 1650 | 1600 | 1500 | 1450 | 1400 | 1300 | 1350 | 1300 | 1200 |
CBW 260 | 0,07 – 2000, | 2350 | 2300 | 2150 | 2050 | 2000 | 1850 | 1950 | 1850 | 1700 |
CBW 330 | 0,09 - 2000 | 2950 | 2850 | 2700 | 2600 | 2500 | 2300 | 2400 | 2300 | 2150 |
CBW 400 | 0,11 - 2000 | 3550 | 3450 | 3200 | 3100 | 3000 | 2800 | 2900 | 2800 | 2550 |
CBW 460 | 0,14 - 2000 | 4100 | 4000 | 3750 | 3600 | 3500 | 3250 | 3400 | 3250 | 3000 |
CBW 560 | 0,18- 110 | 4950 | 4800 | 4500 | 4350 | 4200 | 3900 | 4050 | 3900 | 3600 |
CBW 660 | 0,22- 130 | 5900 | 5700 | 5350 | 5200 | 5000 | 4650 | 4800 | 4650 | 4300 |
CBW 760 | 0,27- 150 | 6700 | 6500 | 6100 | 5900 | 5700 | 5300 | 5500 | 5300 | 4900 |
CBW 860 | 0,31 - 180 | 7650 | 7450 | 6950 | 6750 | 6500 | 6050 | 6250 | 6050 | 5550 |
CBW 960 | 0,35 - 220 | 8500 | 8250 | 7700 | 7450 | 7200 | 6700 | 6950 | 6700 | 6150 |
Construction and Key Properties
- Compact dimensions
- Nominal power range 1200W – 8500W
- Energy levels from 27kJ – 675kJ (5s pulse, 120s cycle), depending on resistance value
- Aluminum housing for high IP rating
- IP50-IP65
- Internal wire spirals wound on ceramics for lower resistance
- Internal components of wire spirals wound on mica for lower resistance
- Nickel-chromium alloy 8020 for low thermal drift
- Mica insulation for high dielectric strength
- Filling of Al2O3 or SiO2 for high thermal capacity/high overload capability
- Low surface temperature
- Low noise level
- High vibration resistance
- Thermally expansive mounting feet (CAR type)
- Optional thermal switch or PT100 element for thermal protection
- 300mm wire with sleeve or box connection up to 10 mm2
- Multi-element housings (from 2 to 3)
- Customizable to customer needs and applications (available OEM versions)
CBW resistors are used in wind turbines as filtering resistors and on board medium-power traction systems, such as trams - as braking resistors. In some tram systems, recovered power is used for heating the interior of the tram on cold days.
Maximum Dissipated Power
The maximum continuous power depends absolutely on the incoming water temperature and the temperature increase of the water, which is directly dependent on the water flow. Table 3 shows the maximum continuous power at a given water flow and different ΔT.
Flow Rate L/h | ∆T Water | ∆T Water/Glycol 60/40 | ||||||||
---|---|---|---|---|---|---|---|---|---|---|
10 | 15 | 20 | 25 | 30 | 10 | 15 | 20 | 25 | 30 | |
7 kW | 710 | 470 | 350 | 280 | 240 | 1070 | 710 | 530 | 420 | 360 |
6 kW | 610 | 400 | 300 | 240 | 200 | 920 | 600 | 450 | 360 | 300 |
5 kW | 510 | 340 | 250 | 200 | 170 | 770 | 510 | 380 | 300 | 260 |
4 kW | 400 | 270 | 200 | 160 | 130 | 600 | 410 | 300 | 240 | 200 |
3 kW | 300 | 200 | 150 | 120 | 100 | 450 | 300 | 230 | 180 | 150 |
2 kW | 200 | 130 | 100 | 80 | 70 | 300 | 200 | 150 | 120 | 110 |
1 kW | 100 | 65 | 50 | 40 | 35 | 150 | 100 | 80 | 60 | 50 |
Pressure Drop
The pressure drop strongly depends on the used nozzles. Many customers use their own nozzles, which makes it difficult to provide standard values. For CBW460 resistor with SW22x45.5 and a flow rate of 120 l/h, the pressure drop is 55 mBar per channel, 110 mBar in total, for two cooling tubes included.
Temperature Coefficient | 100 ppm/K | |
---|---|---|
Dielectric Strength | 3500 VAC at 1 minute | |
Insulation Resistance | > 20MΩ / housing | |
Overload at One-second Pulse per Hour | 70 - 250 x (depending on the resistor) | |
Overload at Five-second Pulse per Hour | 20 - 60 x (depending on the resistor) | |
Environment | - 40 °C / +70 °C | |
Value Loss for Wirewound Version | Linear: 40°C = Pn to 70°C = 0.85 * Pn | |
Value Loss for TW 200°C Version | Linear: 40°C = Pn to 70°C = 0.65 * Pn | |
Value Loss for Vertical Mounting | No loss | |
Value Loss for Horizontal Mounting | 0.8 * Pn | |
Value Loss at High Altitudes | 1000m | No loss |
1500m | 0.94 * Pn | |
3000m | 0.82 * Pn | |
Mounting Instructions | It is recommended to keep a distance of 200mm to the nearest element to prevent heating of neighboring components. | |
If two or more inhibitory resistors are mounted next to each other, a distance of 400mm between them should be maintained. If closer, reduce the rated power. | ||
Cooling | The rated power of the resistors applies to passive, air cooling conditions. | |
Vibrations | According to EN 60068-2-6 Frequency Range 1-100Hz Acceleration/Amplitude | |
1 - 13 Hz | ± 1mm | |
13 - 100 Hz | at ± 0.7G | |
Corrosion Resistance | According to IEC 60721-3-3/3K3 (C2 medium) 200h cyclic salt mist IEC60068-2-52 | |
Connection Recommendations | To minimize EMC interference, the use of screens, especially with any PWM, is recommended. | |
Resistance Tolerance | 10% (optionally 5%) | |
Operating Voltage | Can Version | UL: 600VAC / 850VDC; IEC: 690VAC /975VDC |
Wirewound Version | 1000VAC / 1400VDC | |
Resistor Heating Time Constant | 1000-3000s | |
Thermal Switch (optional) | Thermal Switch | 130 / 160 / 180 / 200 °C, 2A, 250 VAC NC |
Minimum Voltage | 2V | |
Minimum Current | 10mA | |
Rated Current/Voltage | 2.5A @ 250VAC cos ʕ=1 | |
Dielectric Voltage | 2000VAC (3500VAC between TS and R) | |
Temperature Requirements for Cables | IP 21 | 80°C |
IP 65 | 90°C |
Applications
CBW power resistors are used in solutions where large power pulses or high average power are present. The resistive elements are immersed in sand. This serves as a high thermal capacity, capable of absorbing large energy pulses. Energy is conducted through the sand and absorbed by the water. Approximately 90% of the total dissipation will be captured by the water, while the remaining portion is emitted into the air. It is also possible to insulate the aluminum housing, thereby promoting the dispersion of almost the entire energy into the water.
CBW resistors are employed in wind turbines as filtering resistors and in medium-power traction vehicles such as trams, where they function as braking resistors. In certain tram systems, the recovered power is utilized to heat the interior of the tram during cold days.
Maximum Distributed Power
The maximum continuous power is absolutely dependent on the incoming water temperature and the increase in water temperature, which is directly linked to water flow rate. Table 3 displays the maximum continuous power at a given water flow rate and varying ΔT.
Flow Rate L/h | ∆ T Water | ∆ T Water/Glycol 60/40 | ||||||||
---|---|---|---|---|---|---|---|---|---|---|
10 | 15 | 20 | 25 | 30 | 10 | 15 | 20 | 25 | 30 | |
7 kW | 710 | 470 | 350 | 280 | 240 | 1070 | 710 | 530 | 420 | 360 |
6 kW | 610 | 400 | 300 | 240 | 200 | 920 | 600 | 450 | 360 | 300 |
5 kW | 510 | 340 | 250 | 200 | 170 | 770 | 510 | 380 | 300 | 260 |
4 kW | 400 | 270 | 200 | 160 | 130 | 600 | 410 | 300 | 240 | 200 |
3 kW | 300 | 200 | 150 | 120 | 100 | 450 | 300 | 230 | 180 | 150 |
2 kW | 200 | 130 | 100 | 80 | 70 | 300 | 200 | 150 | 120 | 110 |
1 kW | 100 | 65 | 50 | 40 | 35 | 150 | 100 | 80 | 60 | 50 |
Pressure Drop
The pressure drop strongly depends on the used nozzles. Many customers use their own nozzles, which makes it difficult to provide standard values. For the CBW460 resistor with SW22x45.5 and a flow rate of 120 l/h, the pressure drop is 55 mBar per channel, 110 mBar in total, for two cooling tubes in the set.
Your review appreciation cannot be sent
Report comment
Report sent
Your report cannot be sent
Write your review
Review sent
Your review cannot be sent