Type | Pn [W] at 40°C | Max Temp °C | R [Ω] min-max | Pulse Load [W] Ambient Temperature 40°C, 120s cycle | ||||
---|---|---|---|---|---|---|---|---|
1-second Duty Cycle | 5-second Duty Cycle | 10-second Duty Cycle | 20-second Duty Cycle | 40-second Duty Cycle | ||||
CCH110 | 100 | 260 | 2 - 1000 | 2500 | 1150 | 800 | 540 | 295 |
ССН166 | 160 | 265 | 4 - 1200 | 5700 | 2380 | 1600 | 930 | 470 |
ССН216 | 200 | 275 | 5 - 1500 | 10500 | 3760 | 2350 | 1180 | 590 |
ССН270 | 260 | 280 | 9 - 1700 | 14200 | 5050 | 3080 | 1540 | 770 |
ССН320 | 300 | 285 | 10 -2000 | 18600 | 6320 | 3550 | 1780 | 890 |
ССН420 | 390 | 295 | 13 - 2000 | 24700 | 8390 | 4590 | 2290 | 1160 |
ССН520 | 480 | 305 | 16 - 2000 | 30300 | 9710 | 5760 | 2880 | 1440 |
ССН620 | 570 | 315 | 20 - 2000 | 38100 | 11900 | 6890 | 3440 | 1720 |
CCH with Built-in Thermal Switch | ||||||||
ССН145 СТ | 80 | 210 | 2 - 1000 | 2540 | 1210 | 850 | 580 | 345 |
ССН201 СТ | 120 | 215 | 4 - 1200 | 5780 | 2480 | 1690 | 920 | 460 |
ССН251 СТ | 160 | 220 | 5 - 1500 | 10600 | 3940 | 2280 | 1140 | 570 |
ССН305 СТ | 200 | 225 | 9 - 1700 | 14500 | 5220 | 2820 | 1410 | 700 |
ССН355 СТ | 230 | 230 | 10 - 2000 | 19100 | 6550 | 3280 | 1640 | 820 |
ССН455 СТ | 300 | 235 | 13 - 2000 | 25300 | 8310 | 4150 | 2080 | 1040 |
ССН555 СТ | 370 | 245 | 16 - 2000 | 30900 | 10000 | 5170 | 2590 | 1290 |
Type | Pn [W] at 40°C | Max Temp °C | R [Ω] min-max | Impulse Load [W] Ambient Temp 40°C, 120s cycle | ||||
---|---|---|---|---|---|---|---|---|
1 Second Duty Cycle | 5 Second Duty Cycle | 10 Second Duty Cycle | 20 Second Duty Cycle | 40 Second Duty Cycle | ||||
CAH / CAV 120C | 55 | 260 | 0,15 - 300 | 1070 | 410 | 320 | 240 | 170 |
CAH / CAV 150C | 65 | 260 | 0,3 - 600 | 2420 | 820 | 600 | 435 | 255 |
CAH / CAV 165 C | 75 | 265 | 0,3 - 800 | 3630 | 1120 | 780 | 540 | 285 |
CAH/CAV 210C | 100 | 270 | 0,6- 1200 | 7030 | 1800 | 1120 | 750 | 375 |
CAH / CAV 240 C | 120 | 275 | 0,7 - 1500 | 9530 | 2350 | 1440 | 850 | 435 |
CAH / CAV 300 C | 155 | 290 | 1-1200 | 12800 | 3150 | 1920 | 1100 | 550 |
CAH / CAV 360 C | 190 | 305 | 1,2 - 2500 | 16700 | 4080 | 2460 | 1320 | 660 |
CAR 85 C | 110 | 260 | 0,1 -300 | 1090 | 420 | 330 | 250 | 180 |
CAR 115C | 155 | 265 | 0,25 -600 | 2480 | 860 | 640 | 470 | 330 |
CAR 130 C | 175 | 265 | 0,3 - 800 | 3750 | 1170 | 830 | 600 | 405 |
CAR 1750 C | 240 | 275 | 0,5 - 1200 | 7420 | 1910 | 1230 | 830 | 570 |
CAR 205 C | 280 | 285 | 0,7 - 1400 | 10200 | 2540 | 1590 | 1050 | 700 |
CAR 265 C | 367 | 300 | 1,0 - 2000 | 13800 | 3460 | 2140 | 1420 | 940 |
CAR 325 C | 450 | 320 | 1,2-2500 | 18100 | 4460 | 2750 | 1810 | 1170 |
Type | Pn [W] at 40°C | Max Temp °C | R [Ω] min-max | Impulse Load [W] Ambient Temp 40°C, Cycle 120s | ||||
---|---|---|---|---|---|---|---|---|
1 Second Duty | 5 Seconds Duty | 10 Seconds Duty | 20 Seconds Duty | 40 Seconds Duty | ||||
CAH / CAV 145 CT | 42 | 230 | 0,15 - 300 | 1070 | 410 | 320 | 240 | 170 |
CAH/CAV 175 CT | 50 | 230 | 0,3 - 600 | 2420 | 820 | 600 | 435 | 255 |
CAH / CAV 190 CT | 57 | 230 | 0,3 - 800 | 3630 | 1120 | 780 | 540 | 285 |
CAH / CAV 235 CT | 76 | 230 | 0,6- 1200 | 7030 | 1800 | 1120 | 750 | 375 |
CAH / CAV 265 CT | 92 | 240 | 0,7 - 1500 | 9530 | 2350 | 1440 | 850 | 435 |
CAH/CAV 325 CT | 118 | 250 | 1 - 1200 | 12800 | 3150 | 1920 | 1100 | 550 |
CAH / CAV 385 CT | 145 | 270 | 1,2 - 2500 | 16700 | 4080 | 2460 | 1320 | 660 |
CAR 110 CT/K/DT | 100 | 260 | 0,1 - 300 | 1090 | 420 | 330 | 250 | 180 |
CAR 140 CT/K/DT | 125 | 270 | 0,25 - 600 | 2480 | 860 | 640 | 470 | 330 |
CAR 155 CT/K/DT | 130 | 272 | 0,3 - 800 | 3750 | 1170 | 830 | 600 | 405 |
CAR 200 CT/K/DT | 165 | 265 | 0,5 - 1200 | 7420 | 1910 | 1230 | 830 | 570 |
CAR 230 CT/K/DT | 190 | 265 | 0,7 - 1400 | 10200 | 2540 | 1590 | 1050 | 700 |
CAR 290 CT/K/DT | 230 | 268 | 1,0-2000 | 13800 | 3460 | 2140 | 1420 | 940 |
CAR 350 CT/K/DT | 275 | 270 | 1,2 - 2500 | 18100 | 4460 | 2750 | 1810 | 1170 |
*Impulse ranges for short pulses depend on the resistance values. Resistors with lower resistance values have more current than resistors with higher resistance values. The ranges in this table refer to resistors around 40Ω.
Type | Pn [W] at 40°C | Max Temp °C | R [Ω] min-max | Impulse Load [kW] Ambient Temp 40°C, Cycle 120s | ||||
---|---|---|---|---|---|---|---|---|
1 Second Duty | 5 Seconds Duty | 10 Seconds Duty | 20 Seconds Duty | 40 Seconds Duty | ||||
CCR-V 1 16C | 185 | 250 | 2 - 1000 | 2,2 | 1 | 0,7 | 0,5 | 0,4 |
CCR-V 172 C | 260 | 250 | 4- 1200 | 4,7 | 2,1 | 1,5 | 1 | 0,7 |
CCR-V 222 C | 330 | 255 | 6- 1500 | 7,1 | 3,1 | 2,2 | 1,5 | 1 |
CCR-V 276 C | 400 | 260 | 9-1700 | 10,8 | 5,1 | 3,5 | 2,3 | 1,4 |
CCR-V 326 C | 500 | 265 | 10 -2000 | 18,1 | 7,4 | 4,9 | 3,1 | 1,7 |
CCR-V 426 C | 635 | 275 | 13 - 2000 | 29,7 | 11,1 | 7 | 4,3 | 2,3 |
CCR-V 526 C | 815 | 285 | 16 - 2000 | 30,6 | 12 | 7,7 | 4,8 | 2,9 |
Type | Pn [W] at 40°C | Max Temp °C | R [Ω] min-max | Impulse Load [kW] Ambient Temp 40°C, Cycle 120s | ||||
---|---|---|---|---|---|---|---|---|
1 Second Duty | 5 Seconds Duty | 10 Seconds Duty | 20 Seconds Duty | 40 Seconds Duty | ||||
CCR-V 135 CT | 140 | 230 | 2 - 1000 | 2,2 | 1 | 0,7 | 0,5 | 0,4 |
CCR-V 191 CT | 190 | 250 | 4- 1200 | 4,7 | 2,1 | 1,5 | 1 | 0,7 |
CCR-V 241 CT | 250 | 255 | 6- 1500 | 7,1 | 3,2 | 2,2 | 1,5 | 0,9 |
CCR-V 295 CT | 300 | 260 | 9-1700 | 13,8 | 5,9 | 3,9 | 2,2 | 1,1 |
CCR-V 345 CT | 380 | 265 | 10 -2000 | 18,3 | 7,5 | 4,9 | 2,8 | 1,4 |
CCR-V 445 CT | 480 | 275 | 13 - 2000 | 29,7 | 11,1 | 7 | 3,5 | 1,8 |
CCR-V 545 CT | 620 | 285 | 16- 2000 | 17,8 | 7,1 | 4,7 | 2,9 | 1,9 |
CCR-V 645 CT | 790 | 290 | 20 - 2000 | 40,6 | 15,9 | 10,5 | 6,6 | 4,1 |
Type | Pn [W] at 40°C | Max Temp °C | R [Ω] min-max | Impulse Load [kW] Ambient Temp 40°C, Cycle 120s | ||||
---|---|---|---|---|---|---|---|---|
1 Second Duty | 5 Seconds Duty | 10 Seconds Duty | 20 Seconds Duty | 40 Seconds Duty | ||||
CCR-V 135 B/D T | 140 | 230 | 2 - 1000 | 2,2 | 1 | 0,7 | 0,5 | 0,4 |
CCR-V 191 B/D T | 190 | 250 | 4- 1200 | 4,7 | 2.1 | 1,5 | 1 | 0,7 |
CCR-V 241 B/D T | 250 | 255 | 6- 1500 | 7,1 | 3.2 | 2,2 | 1,5 | 0,9 |
CCR-V 295 B/D T | 300 | 260 | 9- 1700 | 13,8 | 5.9 | 3,9 | 2,2 | 1,1 |
CCR-V 345 B/D T | 380 | 265 | 10- 2000 | 18,3 | 7.5 | 4,9 | 2,8 | 1,4 |
CCR-V 445 B/D T | 480 | 275 | 13 - 2000 | 29,7 | 11.1 | 7 | 3,5 | 1,8 |
CCR-V 545 B/D T | 620 | 285 | 16 - 2000 | 17,8 | 7,1 | 4,7 | 2,9 | 1,9 |
CCR-V 645 B/D T | 790 | 290 | 20 - 2000 | 40,6 | 15,9 | 10,5 | 6,6 | 4,1 |
Temperature Coefficient | 100 ppm/K | |
---|---|---|
Dielectric Strength | 3500 VAC at 1 minute | |
Insulation Resistance | > 20MΩ / casing | |
Overload at one-second pulse per hour | 10 - 100 x (depending on the resistor) | |
Overload at five-second pulse per hour | 4 - 25 x (depending on the resistor) | |
Environment | - 40 °C / +70 °C | |
Value loss in wired version | Linear: 40°C = Pn to 70°C = 0.85 * Pn | |
Value loss in TW 200°C version | Linear: 40°C = Pn to 70°C = 0.65 * Pn | |
Value loss in vertical mounting | No loss | |
Value loss in horizontal mounting | 0.8 * Pn | |
Value loss at high altitudes | 1000m | No loss |
1500m | 0.94 * Pn | |
3000m | 0.82 * Pn | |
Installation Instructions | A distance of 200mm to the nearest component is recommended to prevent heating of adjacent elements. | |
If two or more braking resistors are mounted side by side, a distance of 400mm between them should be maintained. If closer, the rated power should be reduced. | ||
Cooling | The rated power of resistors refers to passive, air-cooled conditions. | |
Vibrations | According to EN 60068-2-6Frequency range 1-100HzAcceleration/amplitude | |
1 - 13 Hz | ± 1mm | |
13 - 100 Hz | at ± 0.7G | |
Corrosion Resistance | According to IEC 60721-3-3/3K3 (C2 medium)200h cyclic salt mist IEC 60068-2-52 | |
Connection Recommendations | To minimize EMC interference, the use of shields is recommended, especially with any PWM. | |
Resistance Tolerance | ± 10% (optional 5%) | |
Operating Voltage | Standard | UL: 600VAC / 850VDC ; IEC: 690VAC / 975VDC |
Resistor Heating Time Constant | 1000s | |
Thermal Switch (optional) | Thermal Switch | 130 / 160 / 180 / 200 °C. 2A. 250 VAC NC |
Minimum Voltage | 2V | |
Minimum Current | 10mA | |
Rated Current/Voltage | 2.5A @ 250VAC cos ʕ=1 | |
Dielectric Voltage | 2000VAC (3500VAC between TS and R) | |
Temperature Requirements for Cables | IP 21 | 80°C |
IP 65 | 90°C |
Are you interested in this product? Do you need additional information or individual pricing?
Type | Pn [W] at 40°C | Max Temp °C | R [Ω] min-max | Pulse Load [W] Ambient Temperature 40°C, 120s cycle | ||||
---|---|---|---|---|---|---|---|---|
1-second Duty Cycle | 5-second Duty Cycle | 10-second Duty Cycle | 20-second Duty Cycle | 40-second Duty Cycle | ||||
CCH110 | 100 | 260 | 2 - 1000 | 2500 | 1150 | 800 | 540 | 295 |
ССН166 | 160 | 265 | 4 - 1200 | 5700 | 2380 | 1600 | 930 | 470 |
ССН216 | 200 | 275 | 5 - 1500 | 10500 | 3760 | 2350 | 1180 | 590 |
ССН270 | 260 | 280 | 9 - 1700 | 14200 | 5050 | 3080 | 1540 | 770 |
ССН320 | 300 | 285 | 10 -2000 | 18600 | 6320 | 3550 | 1780 | 890 |
ССН420 | 390 | 295 | 13 - 2000 | 24700 | 8390 | 4590 | 2290 | 1160 |
ССН520 | 480 | 305 | 16 - 2000 | 30300 | 9710 | 5760 | 2880 | 1440 |
ССН620 | 570 | 315 | 20 - 2000 | 38100 | 11900 | 6890 | 3440 | 1720 |
CCH with Built-in Thermal Switch | ||||||||
ССН145 СТ | 80 | 210 | 2 - 1000 | 2540 | 1210 | 850 | 580 | 345 |
ССН201 СТ | 120 | 215 | 4 - 1200 | 5780 | 2480 | 1690 | 920 | 460 |
ССН251 СТ | 160 | 220 | 5 - 1500 | 10600 | 3940 | 2280 | 1140 | 570 |
ССН305 СТ | 200 | 225 | 9 - 1700 | 14500 | 5220 | 2820 | 1410 | 700 |
ССН355 СТ | 230 | 230 | 10 - 2000 | 19100 | 6550 | 3280 | 1640 | 820 |
ССН455 СТ | 300 | 235 | 13 - 2000 | 25300 | 8310 | 4150 | 2080 | 1040 |
ССН555 СТ | 370 | 245 | 16 - 2000 | 30900 | 10000 | 5170 | 2590 | 1290 |
Type | Pn [W] at 40°C | Max Temp °C | R [Ω] min-max | Impulse Load [W] Ambient Temp 40°C, 120s cycle | ||||
---|---|---|---|---|---|---|---|---|
1 Second Duty Cycle | 5 Second Duty Cycle | 10 Second Duty Cycle | 20 Second Duty Cycle | 40 Second Duty Cycle | ||||
CAH / CAV 120C | 55 | 260 | 0,15 - 300 | 1070 | 410 | 320 | 240 | 170 |
CAH / CAV 150C | 65 | 260 | 0,3 - 600 | 2420 | 820 | 600 | 435 | 255 |
CAH / CAV 165 C | 75 | 265 | 0,3 - 800 | 3630 | 1120 | 780 | 540 | 285 |
CAH/CAV 210C | 100 | 270 | 0,6- 1200 | 7030 | 1800 | 1120 | 750 | 375 |
CAH / CAV 240 C | 120 | 275 | 0,7 - 1500 | 9530 | 2350 | 1440 | 850 | 435 |
CAH / CAV 300 C | 155 | 290 | 1-1200 | 12800 | 3150 | 1920 | 1100 | 550 |
CAH / CAV 360 C | 190 | 305 | 1,2 - 2500 | 16700 | 4080 | 2460 | 1320 | 660 |
CAR 85 C | 110 | 260 | 0,1 -300 | 1090 | 420 | 330 | 250 | 180 |
CAR 115C | 155 | 265 | 0,25 -600 | 2480 | 860 | 640 | 470 | 330 |
CAR 130 C | 175 | 265 | 0,3 - 800 | 3750 | 1170 | 830 | 600 | 405 |
CAR 1750 C | 240 | 275 | 0,5 - 1200 | 7420 | 1910 | 1230 | 830 | 570 |
CAR 205 C | 280 | 285 | 0,7 - 1400 | 10200 | 2540 | 1590 | 1050 | 700 |
CAR 265 C | 367 | 300 | 1,0 - 2000 | 13800 | 3460 | 2140 | 1420 | 940 |
CAR 325 C | 450 | 320 | 1,2-2500 | 18100 | 4460 | 2750 | 1810 | 1170 |
Type | Pn [W] at 40°C | Max Temp °C | R [Ω] min-max | Impulse Load [W] Ambient Temp 40°C, Cycle 120s | ||||
---|---|---|---|---|---|---|---|---|
1 Second Duty | 5 Seconds Duty | 10 Seconds Duty | 20 Seconds Duty | 40 Seconds Duty | ||||
CAH / CAV 145 CT | 42 | 230 | 0,15 - 300 | 1070 | 410 | 320 | 240 | 170 |
CAH/CAV 175 CT | 50 | 230 | 0,3 - 600 | 2420 | 820 | 600 | 435 | 255 |
CAH / CAV 190 CT | 57 | 230 | 0,3 - 800 | 3630 | 1120 | 780 | 540 | 285 |
CAH / CAV 235 CT | 76 | 230 | 0,6- 1200 | 7030 | 1800 | 1120 | 750 | 375 |
CAH / CAV 265 CT | 92 | 240 | 0,7 - 1500 | 9530 | 2350 | 1440 | 850 | 435 |
CAH/CAV 325 CT | 118 | 250 | 1 - 1200 | 12800 | 3150 | 1920 | 1100 | 550 |
CAH / CAV 385 CT | 145 | 270 | 1,2 - 2500 | 16700 | 4080 | 2460 | 1320 | 660 |
CAR 110 CT/K/DT | 100 | 260 | 0,1 - 300 | 1090 | 420 | 330 | 250 | 180 |
CAR 140 CT/K/DT | 125 | 270 | 0,25 - 600 | 2480 | 860 | 640 | 470 | 330 |
CAR 155 CT/K/DT | 130 | 272 | 0,3 - 800 | 3750 | 1170 | 830 | 600 | 405 |
CAR 200 CT/K/DT | 165 | 265 | 0,5 - 1200 | 7420 | 1910 | 1230 | 830 | 570 |
CAR 230 CT/K/DT | 190 | 265 | 0,7 - 1400 | 10200 | 2540 | 1590 | 1050 | 700 |
CAR 290 CT/K/DT | 230 | 268 | 1,0-2000 | 13800 | 3460 | 2140 | 1420 | 940 |
CAR 350 CT/K/DT | 275 | 270 | 1,2 - 2500 | 18100 | 4460 | 2750 | 1810 | 1170 |
*Impulse ranges for short pulses depend on the resistance values. Resistors with lower resistance values have more current than resistors with higher resistance values. The ranges in this table refer to resistors around 40Ω.
Type | Pn [W] at 40°C | Max Temp °C | R [Ω] min-max | Impulse Load [kW] Ambient Temp 40°C, Cycle 120s | ||||
---|---|---|---|---|---|---|---|---|
1 Second Duty | 5 Seconds Duty | 10 Seconds Duty | 20 Seconds Duty | 40 Seconds Duty | ||||
CCR-V 1 16C | 185 | 250 | 2 - 1000 | 2,2 | 1 | 0,7 | 0,5 | 0,4 |
CCR-V 172 C | 260 | 250 | 4- 1200 | 4,7 | 2,1 | 1,5 | 1 | 0,7 |
CCR-V 222 C | 330 | 255 | 6- 1500 | 7,1 | 3,1 | 2,2 | 1,5 | 1 |
CCR-V 276 C | 400 | 260 | 9-1700 | 10,8 | 5,1 | 3,5 | 2,3 | 1,4 |
CCR-V 326 C | 500 | 265 | 10 -2000 | 18,1 | 7,4 | 4,9 | 3,1 | 1,7 |
CCR-V 426 C | 635 | 275 | 13 - 2000 | 29,7 | 11,1 | 7 | 4,3 | 2,3 |
CCR-V 526 C | 815 | 285 | 16 - 2000 | 30,6 | 12 | 7,7 | 4,8 | 2,9 |
Type | Pn [W] at 40°C | Max Temp °C | R [Ω] min-max | Impulse Load [kW] Ambient Temp 40°C, Cycle 120s | ||||
---|---|---|---|---|---|---|---|---|
1 Second Duty | 5 Seconds Duty | 10 Seconds Duty | 20 Seconds Duty | 40 Seconds Duty | ||||
CCR-V 135 CT | 140 | 230 | 2 - 1000 | 2,2 | 1 | 0,7 | 0,5 | 0,4 |
CCR-V 191 CT | 190 | 250 | 4- 1200 | 4,7 | 2,1 | 1,5 | 1 | 0,7 |
CCR-V 241 CT | 250 | 255 | 6- 1500 | 7,1 | 3,2 | 2,2 | 1,5 | 0,9 |
CCR-V 295 CT | 300 | 260 | 9-1700 | 13,8 | 5,9 | 3,9 | 2,2 | 1,1 |
CCR-V 345 CT | 380 | 265 | 10 -2000 | 18,3 | 7,5 | 4,9 | 2,8 | 1,4 |
CCR-V 445 CT | 480 | 275 | 13 - 2000 | 29,7 | 11,1 | 7 | 3,5 | 1,8 |
CCR-V 545 CT | 620 | 285 | 16- 2000 | 17,8 | 7,1 | 4,7 | 2,9 | 1,9 |
CCR-V 645 CT | 790 | 290 | 20 - 2000 | 40,6 | 15,9 | 10,5 | 6,6 | 4,1 |
Type | Pn [W] at 40°C | Max Temp °C | R [Ω] min-max | Impulse Load [kW] Ambient Temp 40°C, Cycle 120s | ||||
---|---|---|---|---|---|---|---|---|
1 Second Duty | 5 Seconds Duty | 10 Seconds Duty | 20 Seconds Duty | 40 Seconds Duty | ||||
CCR-V 135 B/D T | 140 | 230 | 2 - 1000 | 2,2 | 1 | 0,7 | 0,5 | 0,4 |
CCR-V 191 B/D T | 190 | 250 | 4- 1200 | 4,7 | 2.1 | 1,5 | 1 | 0,7 |
CCR-V 241 B/D T | 250 | 255 | 6- 1500 | 7,1 | 3.2 | 2,2 | 1,5 | 0,9 |
CCR-V 295 B/D T | 300 | 260 | 9- 1700 | 13,8 | 5.9 | 3,9 | 2,2 | 1,1 |
CCR-V 345 B/D T | 380 | 265 | 10- 2000 | 18,3 | 7.5 | 4,9 | 2,8 | 1,4 |
CCR-V 445 B/D T | 480 | 275 | 13 - 2000 | 29,7 | 11.1 | 7 | 3,5 | 1,8 |
CCR-V 545 B/D T | 620 | 285 | 16 - 2000 | 17,8 | 7,1 | 4,7 | 2,9 | 1,9 |
CCR-V 645 B/D T | 790 | 290 | 20 - 2000 | 40,6 | 15,9 | 10,5 | 6,6 | 4,1 |
Temperature Coefficient | 100 ppm/K | |
---|---|---|
Dielectric Strength | 3500 VAC at 1 minute | |
Insulation Resistance | > 20MΩ / casing | |
Overload at one-second pulse per hour | 10 - 100 x (depending on the resistor) | |
Overload at five-second pulse per hour | 4 - 25 x (depending on the resistor) | |
Environment | - 40 °C / +70 °C | |
Value loss in wired version | Linear: 40°C = Pn to 70°C = 0.85 * Pn | |
Value loss in TW 200°C version | Linear: 40°C = Pn to 70°C = 0.65 * Pn | |
Value loss in vertical mounting | No loss | |
Value loss in horizontal mounting | 0.8 * Pn | |
Value loss at high altitudes | 1000m | No loss |
1500m | 0.94 * Pn | |
3000m | 0.82 * Pn | |
Installation Instructions | A distance of 200mm to the nearest component is recommended to prevent heating of adjacent elements. | |
If two or more braking resistors are mounted side by side, a distance of 400mm between them should be maintained. If closer, the rated power should be reduced. | ||
Cooling | The rated power of resistors refers to passive, air-cooled conditions. | |
Vibrations | According to EN 60068-2-6Frequency range 1-100HzAcceleration/amplitude | |
1 - 13 Hz | ± 1mm | |
13 - 100 Hz | at ± 0.7G | |
Corrosion Resistance | According to IEC 60721-3-3/3K3 (C2 medium)200h cyclic salt mist IEC 60068-2-52 | |
Connection Recommendations | To minimize EMC interference, the use of shields is recommended, especially with any PWM. | |
Resistance Tolerance | ± 10% (optional 5%) | |
Operating Voltage | Standard | UL: 600VAC / 850VDC ; IEC: 690VAC / 975VDC |
Resistor Heating Time Constant | 1000s | |
Thermal Switch (optional) | Thermal Switch | 130 / 160 / 180 / 200 °C. 2A. 250 VAC NC |
Minimum Voltage | 2V | |
Minimum Current | 10mA | |
Rated Current/Voltage | 2.5A @ 250VAC cos ʕ=1 | |
Dielectric Voltage | 2000VAC (3500VAC between TS and R) | |
Temperature Requirements for Cables | IP 21 | 80°C |
IP 65 | 90°C |