-
BackX
-
Components
-
-
Category
-
Semiconductors
- Diodes
- Thyristors
-
Electro-insulated Modules
- Electro-insulated Modules | VISHAY (IR)
- Electro-insulated Modules | INFINEON (EUPEC)
- Electro-insulated Modules | Semikron
- Electro-insulated Modules | POWEREX
- Electro-insulated Modules | IXYS
- Electro-insulated Modules | POSEICO
- Electro-insulated Modules | ABB
- Electro-insulated Modules | TECHSEM
- Go to the subcategory
- Bridge Rectifiers
-
Transistors
- Transistors | GeneSiC
- SiC MOSFET Modules | Mitsubishi
- SiC MOSFET Modules | STARPOWER
- Module SiC MOSFET ABB’s
- IGBT Modules | MITSUBISHI
- Transistor Modules | MITSUBISHI
- MOSFET Modules | MITSUBISHI
- Transistor Modules | ABB
- IGBT Modules | POWEREX
- IGBT Modules | INFINEON (EUPEC)
- Silicon Carbide (SiC) semiconductor elements
- Go to the subcategory
- Gate Drivers
- Power Blocks
- Go to the subcategory
-
Electrical Transducers
-
Current Transducers | LEM
- Closed-Loop Current Transducers (C/L)
- Open-Loop Current Transducers (O/L)
- Current Transducers supplied with unipolar voltage
- 'Eta' Current Transducers
- Current Transducers - LF xx10 Series
- Current Transducers - LH Series
- Current Transducer - HOYL and HOYS Series
- Current Transducers - GO–SME & GO–SMS Series
- AUTOMOTIVE current transducers
- Go to the subcategory
-
Voltage Transducers | LEM
- Voltage Transducers - LV Series
- Voltage Transducers - DVL Series
- Precision Voltage Transducers with double magnetic core - CV Series
- Voltage Transducer for Traction - DV 4200/SP4
- Voltage Transducers - DVM Series
- Voltage Transducer - DVC 1000-P
- Voltage Transducers - DVC 1000 Series
- Go to the subcategory
- Precision Current Transducers | LEM
- Go to the subcategory
-
Current Transducers | LEM
-
Passive components (capacitors, resistors, fuses, filters)
- Resistors
-
Fuses
- Miniature Fuses for electronic circuits - ABC & AGC Series
- Tubular Fast-acting Fuses
- Time-delay Fuse Links with GL/GG & AM characteristics
- Ultrafast Fuse Links
- Fast-acting Fuses (British & American standard)
- Fast-acting Fuses (European standard)
- Traction Fuses
- High-voltage Fuse Links
- Go to the subcategory
- Capacitors
- EMI Filters
- Supercapacitors
- Power surge protection
- Go to the subcategory
-
Relays and Contactors
- Relays and Contactors - Theory
- 3-Phase AC Semiconductor Relays
- DC Semiconductor Relays
- Controllers, Control Systems and Accessories
- Soft Starters and Reversible Relays
- Electromechanical Relays
- Contactors
- Rotary Switches
-
Single-Phase AC Semiconductor Relays
- AC ONE PHASE RELAYS 1 series| D2425 | D2450
- One phase semiconductor AC relays CWA and CWD series
- One phase semiconductor AC relays CMRA and CMRD series
- One phase semiconductor AC relays - PS series
- Double and quadruple semiconductor AC relays - D24 D, TD24 Q, H12D48 D series
- One phase semiconductor relays - gn series
- Ckr series single phase solid state relays
- One phase AC semiconductor relays for DIN bus - ERDA I ERAA series
- 150A AC single phase relays
- Rail Mountable Solid State Relays With Integrated Heat Sink - ENDA, ERDA1 / ERAA1 series
- Go to the subcategory
- Single-Phase AC Semiconductor Relays for PCBs
- Interface Relays
- Go to the subcategory
- Cores and Other Inductive Components
- Heatsinks, Varistors, Thermal Protection
- Fans
- Air Conditioning, Accessories for Electrical Cabinets, Coolers
-
Batteries, Chargers, Buffer Power Supplies and Inverters
- Batteries, Chargers - Theoretical Description
- Modular Li-ion Battery Building Blocks, Custom Batteries, BMS
- Batteries
- Battery Chargers and Accessories
- Uninterruptible Power Supply and Buffer Power Supplies
- Inverters and Photovoltaic Equipments
- Energy storage
- Fuel cells
- Lithium-ion batteries
- Go to the subcategory
-
Automatics
- Futaba Drone Parts
- Limit Switches, Microswitches
- Sensors, Transducers
-
Infrared Thermometers (Pyrometers)
- IR-TE Series - Water-proof Palm-sized Radiation Thermometer
- IR-TA Series - Handheld Type Radiation Thermometer
- IR-H Series - Handheld Type Radiation Thermometer
- IR-BA Series - High-speed Compact Radiation Thermometer
- IR-FA Series - Fiber Optic Radiation Thermometer
- IR-BZ Series - Compact Infrared Thermometers
- Go to the subcategory
- Counters, Time Relays, Panel Meters
- Industrial Protection Devices
- Light and Sound Signalling
- Thermographic Camera
- LED Displays
- Control Equipments
-
Recorders
- Hybrid Recorders - AL3000 Series | CHINO
- Graphic Recorder - KR2000 Series | CHINO
- Ubiquitous Recorders - KR5000 Series | CHINO
- Palm-sized Temperature/Humidity Meters - HN-CH Series | CHINO
- Consumables for Recorders
- 71VR1 - Compact Paperless Recorder | M-SYSTEM
- Graphic Recorder - KR3000 Series | CHINO
- PC Recorders - R1M Series | M-SYSTEM
- PC Recorders - R2M Series | M-SYSTEM
- PC Recorders - RZMS Series | M-SYSTEM
- PC Recorders - RZUS Series | M-SYSTEM
- Go to the subcategory
- Go to the subcategory
-
Cables, Litz wires, Conduits, Flexible connections
- Wires
- Litz wires
- Cables for extreme applications
- Sleevings
-
Braids
- Flat Braids
- Round Braids
- Very Flexible Flat Braids
- Very Flexible Round Braids
- Cylindrical Cooper Braids
- Cylindrical Cooper Braids and Sleevings
- Flexible Earthing Connections
- Galvanized and Stainless Steel Cylindrical Braids
- PCV Insulated Copper Braids (temp. up to 85C)
- Flat Aluminium Braids
- Junction Set - Braids and Tubes
- Go to the subcategory
- Traction Equipment
- Cable Terminals
- Flexible Insulated Busbars
- Flexible Multilayer Busbars
- Cable Duct Systems
- Hoses
- Go to the subcategory
- View all categories
-
Semiconductors
-
-
- Suppliers
-
Applications
- CNC Machine Tools
- DC and AC Drives (Inverters)
- Energetics
- Energy bank
- Equipment and Components for Hazardous Areas [Ex]
- Equipment for Distribution, Control and Telecommunications Cabinets
- HVAC Automation
- Induction Heating
- Industrial Automation
- Industrial Protective Devices
- Machines for Drying and Wood Processing
- Machines for Thermoforming Plastics
- Mining, Metallurgy and Foundry
- Motors and Transformers
- Power Supplies (UPS) and Rectifier Systems
- Printing
- Temperature Measurement and Regulation
- Test and Laboratory Measurements
- Tram and Railway Traction
- Welding Machines
-
Assembly
-
-
Montaż urządzeń
- Assembly of equipment on request
- Designing and Assembling of Busbar Cabinets, Switching Cabinets, Power Cabinets
- Power systems installation
- Components
- Machines built for order
- R&D research and development work
-
Industrial Testers
- Tester for diodes and thyristors measurement
- Thermal and motor circuit breakers testing stand
- Varistors and surge protectors testers
- Car fuses testing stand
- Tester for the power diode and thyristor reverse recovery charge Qrr measurement
- Rotor tester FD series
- Circuit breakers tester
- Tester for calibrating relays
- Video inspection tester for gas spring piston rods
- High-current thyristor switch
- Mesh ripping tester
- Go to the subcategory
- View all categories
-
-
-
Inductors
-
-
Modernizacja induktorów
- Repair of used inductors
- Modernization of inductors
-
Production of new inductors
- Inductors for crankshaft hardening
- Hardening of band saw teeth
- Inductors for heating elements before gluing
- Hardening of raceways of automotive wheel hub bearings
- Hardening of the drive transmission components
- Hardening of stepped shafts
- Heating in contraction joints
- Induction for scanning hardening
- Soft soldering
- Billet heaters
- Go to the subcategory
- Knowledge base
- View all categories
-
-
-
Induction devices
-
-
Urządzenia indukcyjne
-
Induction heating generators
-
Induction Heating Products Ambrell
- Generators power 500 W, frequency 150 - 400 kHz
- Generators power 1.2 - 2.4 kW, frequency 150 - 400 kHz
- Generators power 4.2 - 10 kW, frequency 150 - 400 kHz
- Generators power 10-15 kW, frequency 50-150 kHz
- Generators power 30-45 kW, frequency 50-150 kHz
- Generators power 65-135 kW, frequency 50-150 kHz
- Generators power 180-270 kW, frequency 50-150 kHz
- Generators power 20-35-50 kW, frequency 15-45 kHz
- Generators power 75-150 kW, frequency 15-45 kHz
- Generators power 200-500 kW, frequency 15-45 kHz
- Generators power 20-50 kW, frequency 5-15 kHz
- Go to the subcategory
- Induction heating products Denki Kogyo
-
JKZ induction heating generators
- Generators CX, frequency: 50-120kHz, power: 5-25kW
- Generators SWS, frequency: 15-30kHz, power: 25-260kW
- Molding and forging furnaces MFS, frequency: 0,5-10kHz, power: 80-500kW
- Melting metals furnaces MFS, frequency: 0,5-10kHz, power: 70-200kW
- Generators UHT, frequency: 200-400kHz, power: 10-160kW
- Go to the subcategory
- Lamp generators for induction heating
- Induction Heating Products - Himmelwerk
- Go to the subcategory
-
Induction Heating Products Ambrell
- Repairs and modernization
- Peripherals
-
Applications
- Medical Applications with Precision Induction Heating
- Applications for automotive industry
- Soldering
- Brazing
- Aluminum Brazing
- Brazing a magnetic steel cutting tool
- Pin Sealing
- Atmospheric Brazing
- Soldering brass and steel radiator caps
- Carbide Tipping
- Soldering a copper lug and a wire
- Go to the subcategory
- Knowledge base
- View all categories
-
Induction heating generators
-
-
-
Service
-
-
asd
- Service of industrial water coolers and air conditioners
- Machines Repairs and Modernizations
- Repair and Maintenance of Power Electronics, Electronic and Industrial Automation Devices
- HV Power Supplies for Electrostatic Precipitators
- Industrial Printers and Labelling Machines
- Certificates / Entitlements
- View all categories
-
-
- Contact
- Zobacz wszystkie kategorie
Photos are for informational purposes only. View product specification
please use latin characters
Buffer power supplies DC-UPC AKKU-TEC
Ensures DC power supply even in case of mains shut-down. Works with batteries as energy storage.
- Protection IP20
- Idle current <3,5mA
- Potential free control output
- Advanced battery charging characteristic I/U DIN 41773-1
- Low discharge protection
- Maximum ambient temperature 50°C (derating above 40°C)
- DIN rail mounting
24V supplies
AKKU-TEC | 2402 | 2403 | 2403 VdS | 2405 | 2410 | 2412 VdS | 2420 | 2420 3ph | 2440 3ph | 2403 DC |
---|---|---|---|---|---|---|---|---|---|---|
Input voltage | 115-230 VAC | 230 VAC | 95V-265 VAC | 115-230 VAC | 230 VAC | 230 VAC | 230 VAC | 3x400-500 VAC | 3x400-500 VAC | 24 VDC |
Mains frequency | 47-63 HZ | 47-63 HZ | 47-63 HZ | 47-63 HZ | 47-63 HZ | 47-63 HZ | 47-63 HZ | 45-65 Hz | 45-65 Hz | - |
Output voltage | 24 VDC | |||||||||
Output voltage at battery operation | 26,8-19,8 VDC | 26,8-19,8 VDC | 28,62-21,60 VDC | 26,8-19,8 VDC | 26,8-19,8 VDC | 28,62-21,60 VDC | 26,8-19,8 VDC | 26,8-19,8 VDC | 26,8-19,8 VDC | 26,8-19,8 VDC |
Final charging voltage | 26,8 VDC | 26,8 VDC | 27,4 VDC | 26,8 VDC | 26,8 VDC | 27,4 VDC | 26,8 VDC | 26,8 VDC | 26,8 VDC | 26,8 VDC |
Maximum curernt | 2 A | 2,85 A | 3 A | 5 A | 10 A | 12 A | 20 A | 20 A | 40 A | 2,85 A |
Maximum charging current | 2,1 A | 2,85 A | 3 A | 5,5 A | 11 A | 12 A | 22 A | 22 A | 44 A | 2,85 A |
Idle current | <3,5 mA | |||||||||
Charging characteristic | I/U DIN 41773-1 | |||||||||
Maximum ambient temperature | 50°C (derating above 40°C) | |||||||||
Low discharge protection | Yes | |||||||||
Input/output isolation | According to EN 61558-2-17 | |||||||||
Class of protection | I | |||||||||
Type of protection | IP20 | |||||||||
EMV according to EN55011, EN50082-2 | yes | yes | EN50178:1998, EN54-4:1997+ A1:2002+ A2:2006, EN1210110:2006+ B1:2009, EN61000-6-4, EN61000-6-2 | yes | yes | EN50178:1998, EN54-4:1997+ A1:2002+ A2:2006, EN1210110:2006+ B1:2009, EN61000-6-4, EN61000-6-2 | yes | yes | yes | yes |
Weight | 0,55 kg | 0,55 kg | 0,93 kg | 1,26 kg | 1,6 kg | 1,56 kg | 2,87 kg | 2,54 kg | 3,6 kg | 0,6 kg |
12V and 48V supplies
AKKU-TEC | 1203 | 1208 | 1210 | 4801 | 4803 | 4810 |
---|---|---|---|---|---|---|
Input voltage | 115-230 VAC | |||||
Mains frequency | 47-63 HZ | |||||
Output voltage | 12 VDC | 48 VDC | ||||
Output voltage at battery operation | 13,2-9,9 VDC | 52,8-39,6 VDC | ||||
Final charging voltage | 13,2 VDC | 52,8 V | ||||
Maximum curernt | 2,85 A | 8 A | 10 A | 5 A | 10 A | 12 A |
Maximum charging current | 2,85 A | 8 A | 11 A | 5,5 A | 11 A | 12 A |
Idle current | <3,5 mA | |||||
Charging characteristic | I/U DIN 41773-1 | |||||
Maximum ambient temperature | 50°C (derating above 40°C) | |||||
Low discharge protection | Yes | |||||
Input/output isolation | According EN 61558-2-17 | |||||
Class of protection | I | |||||
Type of protection | IP20 | |||||
EMV according to EN55011, EN50082-2 | Yes | |||||
Weight | 0,35 kg | 1,1 kg | 1,6 kg | 0,35 kg | 1,1 kg | 2,4 kg |
Send an inquiry
Are you interested in this product? Do you need additional information or individual pricing?
Contact us
Buffer power supplies DC-UPC AKKU-TEC
Ensures DC power supply even in case of mains shut-down. Works with batteries as energy storage.
- Protection IP20
- Idle current <3,5mA
- Potential free control output
- Advanced battery charging characteristic I/U DIN 41773-1
- Low discharge protection
- Maximum ambient temperature 50°C (derating above 40°C)
- DIN rail mounting
24V supplies
AKKU-TEC | 2402 | 2403 | 2403 VdS | 2405 | 2410 | 2412 VdS | 2420 | 2420 3ph | 2440 3ph | 2403 DC |
---|---|---|---|---|---|---|---|---|---|---|
Input voltage | 115-230 VAC | 230 VAC | 95V-265 VAC | 115-230 VAC | 230 VAC | 230 VAC | 230 VAC | 3x400-500 VAC | 3x400-500 VAC | 24 VDC |
Mains frequency | 47-63 HZ | 47-63 HZ | 47-63 HZ | 47-63 HZ | 47-63 HZ | 47-63 HZ | 47-63 HZ | 45-65 Hz | 45-65 Hz | - |
Output voltage | 24 VDC | |||||||||
Output voltage at battery operation | 26,8-19,8 VDC | 26,8-19,8 VDC | 28,62-21,60 VDC | 26,8-19,8 VDC | 26,8-19,8 VDC | 28,62-21,60 VDC | 26,8-19,8 VDC | 26,8-19,8 VDC | 26,8-19,8 VDC | 26,8-19,8 VDC |
Final charging voltage | 26,8 VDC | 26,8 VDC | 27,4 VDC | 26,8 VDC | 26,8 VDC | 27,4 VDC | 26,8 VDC | 26,8 VDC | 26,8 VDC | 26,8 VDC |
Maximum curernt | 2 A | 2,85 A | 3 A | 5 A | 10 A | 12 A | 20 A | 20 A | 40 A | 2,85 A |
Maximum charging current | 2,1 A | 2,85 A | 3 A | 5,5 A | 11 A | 12 A | 22 A | 22 A | 44 A | 2,85 A |
Idle current | <3,5 mA | |||||||||
Charging characteristic | I/U DIN 41773-1 | |||||||||
Maximum ambient temperature | 50°C (derating above 40°C) | |||||||||
Low discharge protection | Yes | |||||||||
Input/output isolation | According to EN 61558-2-17 | |||||||||
Class of protection | I | |||||||||
Type of protection | IP20 | |||||||||
EMV according to EN55011, EN50082-2 | yes | yes | EN50178:1998, EN54-4:1997+ A1:2002+ A2:2006, EN1210110:2006+ B1:2009, EN61000-6-4, EN61000-6-2 | yes | yes | EN50178:1998, EN54-4:1997+ A1:2002+ A2:2006, EN1210110:2006+ B1:2009, EN61000-6-4, EN61000-6-2 | yes | yes | yes | yes |
Weight | 0,55 kg | 0,55 kg | 0,93 kg | 1,26 kg | 1,6 kg | 1,56 kg | 2,87 kg | 2,54 kg | 3,6 kg | 0,6 kg |
12V and 48V supplies
AKKU-TEC | 1203 | 1208 | 1210 | 4801 | 4803 | 4810 |
---|---|---|---|---|---|---|
Input voltage | 115-230 VAC | |||||
Mains frequency | 47-63 HZ | |||||
Output voltage | 12 VDC | 48 VDC | ||||
Output voltage at battery operation | 13,2-9,9 VDC | 52,8-39,6 VDC | ||||
Final charging voltage | 13,2 VDC | 52,8 V | ||||
Maximum curernt | 2,85 A | 8 A | 10 A | 5 A | 10 A | 12 A |
Maximum charging current | 2,85 A | 8 A | 11 A | 5,5 A | 11 A | 12 A |
Idle current | <3,5 mA | |||||
Charging characteristic | I/U DIN 41773-1 | |||||
Maximum ambient temperature | 50°C (derating above 40°C) | |||||
Low discharge protection | Yes | |||||
Input/output isolation | According EN 61558-2-17 | |||||
Class of protection | I | |||||
Type of protection | IP20 | |||||
EMV according to EN55011, EN50082-2 | Yes | |||||
Weight | 0,35 kg | 1,1 kg | 1,6 kg | 0,35 kg | 1,1 kg | 2,4 kg |
Your review appreciation cannot be sent
Report comment
Report sent
Your report cannot be sent
Write your review
Review sent
Your review cannot be sent