TAC020 current transformer with primary winding
  • TAC020 current transformer with primary winding

Photos are for informational purposes only. View product specification

please use latin characters

Manufacturer: FRER

TAC020 current transformer with primary winding

Technical Data

Thermoplastic material UL94-V0
Operating frequency 50-60Hz
Voltage 0.72kV
Test voltage 3kV * 1’50Hz
Insulation Klasa E
Protection degree IP 20
Continuous overcurrent 1.2In
Rated short-time thermal current (I th) 60 In
Rated dynamic current (I dyn) 2.5 x I th
Safety factor N<5
max. power dissipation (max range value) <3,5W
Operating temperature -25 +50o C
Storage temperature -40 +80o C
Manufactured according to

IEC/E N 60044-1,
VDE, BS, UTE

 
Ratio Burdens [VA] Code
cl. 0.5 cl.1 5 A 1 A
5 A 20 35

TAC020005X05

TAC020005X01

10 A 20 35

TAC020010X05

TAC020010X01

15 A 20 35

TAC020015X05

TAC020015X01

20 A 20 35

TAC020020X05

TAC020020X01

25 A 20 35

TAC020025X05

TAC020025X01

30 A 20 35

TAC020030X05

TAC020030X01

40 A 20 35

TAC020040X05

TAC020040X01

50 A 20 35

TAC020050X05

TAC020050X01

60 A 20 35

TAC020060X05

TAC020060X01

80 A 20 35

TAC020080X05

TAC020080X01

100 A 20 35

TAC020100X05

TAC020100X01

120 A 20 35

TAC020120X05

TAC020120X01

150 A 20 35

TAC020150X05

TAC020150X01

200 A 20 35

TAC020200X05

TAC020200X01

250 A 20 35

TAC020250X05

TAC020250X01

300 A 20 35

TAC020300X05

TAC020300X01

400 A 20 35

TAC020400X05

TAC020400X01

500 A 20 35

TAC020500X05

TAC020500X01

600 A 20 35

TAC020600X05

TAC020600X01

 

Dimensions

Przekładnik prądowy TAC020 z uzwojeniem pierwotnym

Send an inquiry

Are you interested in this product? Do you need additional information or individual pricing?

Contact us
ASK FOR THE PRODUCT close
Thank you for sending your message. We will respond as soon as possible.
ASK FOR THE PRODUCT close
Browse

Add to Wishlist

You must be logged in

Technical Data

Thermoplastic material UL94-V0
Operating frequency 50-60Hz
Voltage 0.72kV
Test voltage 3kV * 1’50Hz
Insulation Klasa E
Protection degree IP 20
Continuous overcurrent 1.2In
Rated short-time thermal current (I th) 60 In
Rated dynamic current (I dyn) 2.5 x I th
Safety factor N<5
max. power dissipation (max range value) <3,5W
Operating temperature -25 +50o C
Storage temperature -40 +80o C
Manufactured according to

IEC/E N 60044-1,
VDE, BS, UTE

 
Ratio Burdens [VA] Code
cl. 0.5 cl.1 5 A 1 A
5 A 20 35

TAC020005X05

TAC020005X01

10 A 20 35

TAC020010X05

TAC020010X01

15 A 20 35

TAC020015X05

TAC020015X01

20 A 20 35

TAC020020X05

TAC020020X01

25 A 20 35

TAC020025X05

TAC020025X01

30 A 20 35

TAC020030X05

TAC020030X01

40 A 20 35

TAC020040X05

TAC020040X01

50 A 20 35

TAC020050X05

TAC020050X01

60 A 20 35

TAC020060X05

TAC020060X01

80 A 20 35

TAC020080X05

TAC020080X01

100 A 20 35

TAC020100X05

TAC020100X01

120 A 20 35

TAC020120X05

TAC020120X01

150 A 20 35

TAC020150X05

TAC020150X01

200 A 20 35

TAC020200X05

TAC020200X01

250 A 20 35

TAC020250X05

TAC020250X01

300 A 20 35

TAC020300X05

TAC020300X01

400 A 20 35

TAC020400X05

TAC020400X01

500 A 20 35

TAC020500X05

TAC020500X01

600 A 20 35

TAC020600X05

TAC020600X01

 

Dimensions