TAC021 current transformer for Ø21 / rail 20x10mm
  • TAC021 current transformer for Ø21 / rail 20x10mm

Photos are for informational purposes only. View product specification

please use latin characters

Manufacturer: FRER

TAC021 current transformer for Ø21 / rail 20x10mm

TECHNICAL DATA

Thermoplastic material
UL94-V0
Operating frequency
50-60Hz
Voltage
0.72kV
Test voltage
3kV * 1’50Hz
Insulation
Klasa E
Protection degree
IP 20
Continuous overcurrent
1.2In
Rated short-time thermal current (I th)
60 In
Rated dynamic current (I dyn)
2.5 x I th
Safety factor
N<5
max. power dissipation (max range value)
<2,5W
Operating temperature
-25 +50o C
Storage temperature
-40 +80o C
Manufactured according to

IEC/EN 60044-1,
VDE, BS, UTE

Integrated secondary terminals
6mm2
 

SECONDARY 5A

Ratio Burdens
[VA]
Code
cl. 0.5 cl. 1 cl. 3
30/5 A     1.5

TAC021030X05

40/5 A     3

TAC021040X05

50/5 A   2 5

TAC021050X05

60/5 A   3 6

TAC021060X05

80/5 A   4 8

TAC021080X05

100/5 A 3 6 12

TAC021100X05

120/5 A 4 8 15

TAC021120X05

150/5 A 6 12 20

TAC021150X05

200/5 A 10 15 25

TAC021200X05

250/5 A 15 25 30

TAC021250X05

SECONDARY 1A

Ratio Burdens
[VA]
Code
cl. 0.5 cl. 1 cl. 3
30/1 A     1.5

TAC021030X01

40/1 A     3

TAC021040X01

50/1 A   2 5

TAC021050X01

60/1 A   3 6

TAC021060X01

80/1 A   4 8

TAC021080X01

100/1 A 3 6 12

TAC021100X01

120/1 A 4 8 15

TAC021120X01

150/1 A 6 12 20

TAC021150X01

200/1 A 10 15 25

TAC021200X01

250/1 A 15 25 30

TAC021250X01

 

Dimensions

Przekładnik prądowy TAC021 na kabel Ø21/ szynę 20x10mm wymiar

Send an inquiry

Are you interested in this product? Do you need additional information or individual pricing?

Contact us
ASK FOR THE PRODUCT close
Thank you for sending your message. We will respond as soon as possible.
ASK FOR THE PRODUCT close
Browse

Add to Wishlist

You must be logged in

TECHNICAL DATA

Thermoplastic material
UL94-V0
Operating frequency
50-60Hz
Voltage
0.72kV
Test voltage
3kV * 1’50Hz
Insulation
Klasa E
Protection degree
IP 20
Continuous overcurrent
1.2In
Rated short-time thermal current (I th)
60 In
Rated dynamic current (I dyn)
2.5 x I th
Safety factor
N<5
max. power dissipation (max range value)
<2,5W
Operating temperature
-25 +50o C
Storage temperature
-40 +80o C
Manufactured according to

IEC/EN 60044-1,
VDE, BS, UTE

Integrated secondary terminals
6mm2
 

SECONDARY 5A

Ratio Burdens
[VA]
Code
cl. 0.5 cl. 1 cl. 3
30/5 A     1.5

TAC021030X05

40/5 A     3

TAC021040X05

50/5 A   2 5

TAC021050X05

60/5 A   3 6

TAC021060X05

80/5 A   4 8

TAC021080X05

100/5 A 3 6 12

TAC021100X05

120/5 A 4 8 15

TAC021120X05

150/5 A 6 12 20

TAC021150X05

200/5 A 10 15 25

TAC021200X05

250/5 A 15 25 30

TAC021250X05

SECONDARY 1A

Ratio Burdens
[VA]
Code
cl. 0.5 cl. 1 cl. 3
30/1 A     1.5

TAC021030X01

40/1 A     3

TAC021040X01

50/1 A   2 5

TAC021050X01

60/1 A   3 6

TAC021060X01

80/1 A   4 8

TAC021080X01

100/1 A 3 6 12

TAC021100X01

120/1 A 4 8 15

TAC021120X01

150/1 A 6 12 20

TAC021150X01

200/1 A 10 15 25

TAC021200X01

250/1 A 15 25 30

TAC021250X01

 

Dimensions

Przekładnik prądowy TAC021 na kabel Ø21/ szynę 20x10mm wymiar

Comments (0)