TAC032 current transformer for Ø24 cable / 32x10mm rail
  • TAC032 current transformer for Ø24 cable / 32x10mm rail

Photos are for informational purposes only. View product specification

please use latin characters

Manufacturer: FRER

TAC032 current transformer for Ø24 cable / 32x10mm rail

Technical Data

Thermoplastic material UL94-V0
Operating frequency 50-60Hz
Voltage 0.72kV
Test voltage 3kV * 1’50Hz
Insulation Klasa E
Protection degree IP 20
Continuous overcurrent 1.2In
Rated short-time thermal current (I th) 40 In
Rated dynamic current (I dyn) 2.5 x I th
Safety factor N<5
max. power dissipation (max range value) <3,5W
Operating temperature -25 +50o C
Storage temperature -40 +80o C
Manufactured according to

IEC/EN 60044-1,
VDE, BS, UTE

Integrated secondary terminals 6mm2
 

SECONDARY 5A

Ratio Burdens
[VA]
Code
cl. 0.5 cl. 1 cl. 3
40/5 A     1

TAC032040X05

50/5 A     1.2

TAC032050X05

60/5 A     1.5

TAC032060X05

80/5 A   1 2.5

TAC032080X05

100/5 A 1 2 3

TAC032100X05

120/5 A 2 3 4

TAC032120X05

150/5 A 2.5 3 5

TAC032150X05

200/5 A 3 5 8

TAC032200X05

250/5 A 4 7 10

TAC032250X05

300/5 A 6 10 12

TAC032300X05

400/5 A 10 12 12

TAC032400X05

500/5 A 12 15 15

TAC032500X05

600/5 A 12 15 15

TAC032600X05

SECONDARY 1A

Ratio Burdens
[VA]
Code
cl. 0.5 cl. 1 cl. 3
40/1 A     1

TAC032040X01

50/1 A     1.2

TAC032050X01

60/1 A     1.5

TAC032060X01

80/1 A   1 2.5

TAC032080X01

100/1 A 1 2 3

TAC032100X01

120/1 A 2 3 4

TAC032120X01

150/1 A 2.5 3 5

TAC032150X01

200/1 A 3 5 8

TAC032200X01

250/1 A 4 7 10

TAC032250X01

300/1 A 6 10 12

TAC032300X01

400/1 A 10 12 12

TAC032400X01

500/1 A 12 15 15

TAC032500X01

600/1 A 12 15 15

TAC032600X01

 

Dimensions

Send an inquiry

Are you interested in this product? Do you need additional information or individual pricing?

Contact us
ASK FOR THE PRODUCT close
Thank you for sending your message. We will respond as soon as possible.
ASK FOR THE PRODUCT close
Browse

Add to Wishlist

You must be logged in

Technical Data

Thermoplastic material UL94-V0
Operating frequency 50-60Hz
Voltage 0.72kV
Test voltage 3kV * 1’50Hz
Insulation Klasa E
Protection degree IP 20
Continuous overcurrent 1.2In
Rated short-time thermal current (I th) 40 In
Rated dynamic current (I dyn) 2.5 x I th
Safety factor N<5
max. power dissipation (max range value) <3,5W
Operating temperature -25 +50o C
Storage temperature -40 +80o C
Manufactured according to

IEC/EN 60044-1,
VDE, BS, UTE

Integrated secondary terminals 6mm2
 

SECONDARY 5A

Ratio Burdens
[VA]
Code
cl. 0.5 cl. 1 cl. 3
40/5 A     1

TAC032040X05

50/5 A     1.2

TAC032050X05

60/5 A     1.5

TAC032060X05

80/5 A   1 2.5

TAC032080X05

100/5 A 1 2 3

TAC032100X05

120/5 A 2 3 4

TAC032120X05

150/5 A 2.5 3 5

TAC032150X05

200/5 A 3 5 8

TAC032200X05

250/5 A 4 7 10

TAC032250X05

300/5 A 6 10 12

TAC032300X05

400/5 A 10 12 12

TAC032400X05

500/5 A 12 15 15

TAC032500X05

600/5 A 12 15 15

TAC032600X05

SECONDARY 1A

Ratio Burdens
[VA]
Code
cl. 0.5 cl. 1 cl. 3
40/1 A     1

TAC032040X01

50/1 A     1.2

TAC032050X01

60/1 A     1.5

TAC032060X01

80/1 A   1 2.5

TAC032080X01

100/1 A 1 2 3

TAC032100X01

120/1 A 2 3 4

TAC032120X01

150/1 A 2.5 3 5

TAC032150X01

200/1 A 3 5 8

TAC032200X01

250/1 A 4 7 10

TAC032250X01

300/1 A 6 10 12

TAC032300X01

400/1 A 10 12 12

TAC032400X01

500/1 A 12 15 15

TAC032500X01

600/1 A 12 15 15

TAC032600X01

 

Dimensions

Comments (0)