Technical Data
Thermoplastic material | UL94-V0 |
Operating frequency | 50-60Hz |
Voltage | 0.72kV |
Test voltage | 3kV * 1’50Hz |
Insulation | Klasa E |
Protection degree | IP 20 |
Continuous overcurrent | 1.2In |
Rated short-time thermal current (I th) | 60 In |
Rated dynamic current (I dyn) | 2.5 x I th |
Safety factor | N<5 |
max. power dissipation (max range value) | <22W |
Operating temperature | -25 +50o C |
Storage temperature | -40 +80o C |
Manufactured according to |
IEC/E N 60044-1, |
SECONDARY 5A
Ratio | Burdens [VA] |
Code | |
---|---|---|---|
cl. 0.5 | cl. 1 | ||
400/5 A | 5 | 10 |
TAT081400X05 |
500/5 A | 5 | 10 |
TAT081500X05 |
600/5 A | 8 | 15 |
TAT081600X05 |
800/5 A | 10 | 20 |
TAT081800X05 |
1000/5 A | 15 | 30 |
TAT0811K0X05 |
1200/5 A | 20 | 40 |
TAT0811K2X05 |
1500/5 A | 20 | 40 |
TAT0811K5X05 |
2000/5 A | 30 | 50 |
TAT0812K0X05 |
2500/5 A | 40 | 60 |
TAT0812K5X05 |
SECONDARY 1A
Ratio | Burdens [VA] |
Code | |
---|---|---|---|
cl. 0.5 | cl. 1 | ||
400/1 A | 5 | 10 |
TAT081400X01 |
500/1 A | 5 | 10 |
TAT081500X01 |
600/1 A | 8 | 15 |
TAT081600X01 |
800/1 A | 10 | 20 |
TAT081800X01 |
1000/1 A | 15 | 30 |
TAT0811K0X01 |
1200/1 A | 20 | 40 |
TAT0811K2X01 |
1500/1 A | 20 | 40 |
TAT0811K5X01 |
2000/1 A | 30 | 50 |
TAT0812K0X01 |
2500/1 A | 40 | 60 |
TAT0812K5X01 |
Dimensions
Are you interested in this product? Do you need additional information or individual pricing?
Technical Data
Thermoplastic material | UL94-V0 |
Operating frequency | 50-60Hz |
Voltage | 0.72kV |
Test voltage | 3kV * 1’50Hz |
Insulation | Klasa E |
Protection degree | IP 20 |
Continuous overcurrent | 1.2In |
Rated short-time thermal current (I th) | 60 In |
Rated dynamic current (I dyn) | 2.5 x I th |
Safety factor | N<5 |
max. power dissipation (max range value) | <22W |
Operating temperature | -25 +50o C |
Storage temperature | -40 +80o C |
Manufactured according to |
IEC/E N 60044-1, |
SECONDARY 5A
Ratio | Burdens [VA] |
Code | |
---|---|---|---|
cl. 0.5 | cl. 1 | ||
400/5 A | 5 | 10 |
TAT081400X05 |
500/5 A | 5 | 10 |
TAT081500X05 |
600/5 A | 8 | 15 |
TAT081600X05 |
800/5 A | 10 | 20 |
TAT081800X05 |
1000/5 A | 15 | 30 |
TAT0811K0X05 |
1200/5 A | 20 | 40 |
TAT0811K2X05 |
1500/5 A | 20 | 40 |
TAT0811K5X05 |
2000/5 A | 30 | 50 |
TAT0812K0X05 |
2500/5 A | 40 | 60 |
TAT0812K5X05 |
SECONDARY 1A
Ratio | Burdens [VA] |
Code | |
---|---|---|---|
cl. 0.5 | cl. 1 | ||
400/1 A | 5 | 10 |
TAT081400X01 |
500/1 A | 5 | 10 |
TAT081500X01 |
600/1 A | 8 | 15 |
TAT081600X01 |
800/1 A | 10 | 20 |
TAT081800X01 |
1000/1 A | 15 | 30 |
TAT0811K0X01 |
1200/1 A | 20 | 40 |
TAT0811K2X01 |
1500/1 A | 20 | 40 |
TAT0811K5X01 |
2000/1 A | 30 | 50 |
TAT0812K0X01 |
2500/1 A | 40 | 60 |
TAT0812K5X01 |