EVR100 DC Relay
  • EVR100 DC Relay

Photos are for informational purposes only. View product specification

please use latin characters

Manufacturer: YM Tech

EVR100 DC Relay

  • EVR100

Application

  • Pre-Charge Relay,
  • Electric Vehicle,
  • Charging System,
  • Solar System,
  • etc.

Magnet coil ratings

Nominal voltage (v)Nominal current (mA)Coil resistance (Ω)Pick-up voltage (V)MaxDrop-out voltage (V)MinMax. voltage (V)MaxCoil power(W) dissipation
DC 220 27 8,600 75% 10% 130% 5.6 ~ 5.9
110 52 2,100
72 83 870
60 95 630
48 117 410
36 156 230
24 245 110
12 480 25
6 952 6.3

Contact ratings

Type1Pole Resistive load (L/R≤1㎳)
Max. Continuous current (wire size 50㎟) 150A
Max. switching current 125A
Max. switching capacity 1200VDC 20A
Contact rating switching voltages 12~1200VDC
Max. cut-off current 300VDC 1000A 3 Ops
Voltage drop across contacts per 100A 30mV Max.
Min. permissible load 12V DC 0.5A
Description S.P On/Off (a)
Contact Arrangement, auxiliary contacts 1Form A (SPST-NO.)
General Aux. Contact Current, Max. 2A 30VDC / 3A 125VAC
General Aux. Contact Current, Min. 100mA 8VDC
Gold alloy Aux. Contacts Max. 0.1A 30VDC / 0.1A 30VAC
Gold alloy Aux. Contacts Min. 1mA 5VDC / 1mA 5VAC

Characteristics

Initial insulation resistanceMin. 100㏁ 500V DC
Expected life Mechanical (Min.) 2×106
Electric (L/R≤1㎳) 450V DC 10A 1×104
250V DC 15A 2×105
Initial breakdown voltage Between open contacts 3500V AC 60 Sec. 10mA
Between contacts & coil 3500V AC 60 Sec. 10mA
Operate time (at 20℃) Max. 20㎳
Release time (at 20℃) Max. 5㎳
Shock resistance Functional Min 147 ㎨ {15G}
Destructive Min 490 ㎨ {50G}
Vibration resistance Functional 100 ㎨ {10G} 10 to 500㎐
Destructive 100 ㎨ {10G} 10 to 500㎐
Conditions for operation transport and storage Ambient temperature -40℃ to +85℃
Humidity 5 to 85% R.H.
Unit weight 300g

Send an inquiry

Are you interested in this product? Do you need additional information or individual pricing?

Contact us
ASK FOR THE PRODUCT close
Thank you for sending your message. We will respond as soon as possible.
ASK FOR THE PRODUCT close
Browse

Add to Wishlist

You must be logged in

Application

  • Pre-Charge Relay,
  • Electric Vehicle,
  • Charging System,
  • Solar System,
  • etc.

Magnet coil ratings

Nominal voltage (v)Nominal current (mA)Coil resistance (Ω)Pick-up voltage (V)MaxDrop-out voltage (V)MinMax. voltage (V)MaxCoil power(W) dissipation
DC 220 27 8,600 75% 10% 130% 5.6 ~ 5.9
110 52 2,100
72 83 870
60 95 630
48 117 410
36 156 230
24 245 110
12 480 25
6 952 6.3

Contact ratings

Type1Pole Resistive load (L/R≤1㎳)
Max. Continuous current (wire size 50㎟) 150A
Max. switching current 125A
Max. switching capacity 1200VDC 20A
Contact rating switching voltages 12~1200VDC
Max. cut-off current 300VDC 1000A 3 Ops
Voltage drop across contacts per 100A 30mV Max.
Min. permissible load 12V DC 0.5A
Description S.P On/Off (a)
Contact Arrangement, auxiliary contacts 1Form A (SPST-NO.)
General Aux. Contact Current, Max. 2A 30VDC / 3A 125VAC
General Aux. Contact Current, Min. 100mA 8VDC
Gold alloy Aux. Contacts Max. 0.1A 30VDC / 0.1A 30VAC
Gold alloy Aux. Contacts Min. 1mA 5VDC / 1mA 5VAC

Characteristics

Initial insulation resistanceMin. 100㏁ 500V DC
Expected life Mechanical (Min.) 2×106
Electric (L/R≤1㎳) 450V DC 10A 1×104
250V DC 15A 2×105
Initial breakdown voltage Between open contacts 3500V AC 60 Sec. 10mA
Between contacts & coil 3500V AC 60 Sec. 10mA
Operate time (at 20℃) Max. 20㎳
Release time (at 20℃) Max. 5㎳
Shock resistance Functional Min 147 ㎨ {15G}
Destructive Min 490 ㎨ {50G}
Vibration resistance Functional 100 ㎨ {10G} 10 to 500㎐
Destructive 100 ㎨ {10G} 10 to 500㎐
Conditions for operation transport and storage Ambient temperature -40℃ to +85℃
Humidity 5 to 85% R.H.
Unit weight 300g
Comments (0)