Technical data
Self estinguishing thermoplastic material |
UL94-V0 | |
---|---|---|
Operating frequency | 45 do 65 Hz | |
Insulation reference voltage | 0,72 kV | |
Test voltage | 3 kV 1min. 50 Hz | |
Insulation | E | |
Protection degree | IP 20 | |
Continuous overcurrent | 1,2 In | |
Rated short-time thermal current (l th) | 5 In(5sec.) | |
Alarms | 1 | |
Contact rating | 100mA, 250Vac | |
Alarm intervention indication | LED | |
Alarm type | MAX | |
Contact type | ||
- normally open | N.O. (cod. X...XMO) | |
- normally closed | N.C. (cod. X…XMC) | |
Alarm configuration | 10 do 120% In | |
Intevention delay | 0 do 6 s. | |
Hysteresis | 5% | |
Operating temperature | -10 +50 oC | |
Storage temperature | -30 +70oC | |
Manufactured according | IEC/EN 60044-1, VDE, BS, UTE | |
Integrated output terminals | 6 mm2 |
Type |
XAC032… |
XAC040… |
XAT061 |
XAT101 |
---|---|---|---|---|
Opening | ||||
Cable | Φ23 | Φ32 | Φ51 | |
Bar size | 32x10 mm | 40x 10 mm | 61 x 31 mm | 101x55 mm |
Pin description and diagram
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
|
RANGE (alarm range) |
XAC032… |
XAC040… |
XAT061… |
XAT101… |
---|---|---|---|---|
Code | ||||
50 A (5 to 60A) |
XAC032050XMC |
|||
100 A (10 to 120 A) |
XAC032100XMC |
|||
150 A (15 to 180A) |
XAC032150XMC |
|||
250 A (25 to 300 A) |
XAC032250XMC |
|||
400 A (40 to 480 A) |
XAC032400XMC |
XAC040400XMC |
||
600 A (60 to 720 A) |
XAC032600XMC |
XAC040600XMC |
XAT061600XMC |
|
1000 A (100 to 1200 A) |
XAC0401K0XMC |
XAT0611K0XMC |
XAT1011K0XMC |
|
1500 A (150 to 1800 A) |
XAT0611K5XMC |
XAT1011K5XMC |
||
2500 A (250 to 3000 A) |
XAT1012K5XMC |
: It is possible to set the Max. alarm threshold from10% to 120% of the current range (Example: Range=100A - Max. alarm threshold from 10A to 120A)
RANGE (alarm range) |
XAC032… |
XAC040… |
XAT061… |
XAT101… |
---|---|---|---|---|
Code | ||||
50 A (5 to 60A) |
XAC032050XMO |
|||
100 A (10 to 120 A) |
XAC032100XMO |
|||
150 A (15 to 180A) |
XAC032150XMO |
|||
250 A (25 to 300 A) |
XAC032250XMO |
|||
400 A (40 to 480 A) |
XAC032400XMO |
XAC040400XMO |
||
600 A (60 to 720 A) |
XAC032600XMO |
XAC040600XMO |
XAT061600XMO |
|
1000 A (100 to 1200 A) |
XAC0401K0XMO |
XAT0611K0XMO |
XAT1011K0XMO |
|
1500 A (150 to 1800 A) |
XAT0611K5XMO |
XAT1011K5XMO |
||
2500 A (250 to 3000 A) |
XAT1012K5XMO |
It is possible to set the Max. alarm threshold from10% to 120% of the current range (Example: Range=100A - Max. alarm threshold from 10A to 120A)
XAC032 |
XAC040 |
![]() |
![]() |
XAT061 |
XAT101 |
![]() |
![]() |
Signal alarm configuration
LED alarm signal
Normally open contact
Normally closed contact
Are you interested in this product? Do you need additional information or individual pricing?
Technical data
Self estinguishing thermoplastic material |
UL94-V0 | |
---|---|---|
Operating frequency | 45 do 65 Hz | |
Insulation reference voltage | 0,72 kV | |
Test voltage | 3 kV 1min. 50 Hz | |
Insulation | E | |
Protection degree | IP 20 | |
Continuous overcurrent | 1,2 In | |
Rated short-time thermal current (l th) | 5 In(5sec.) | |
Alarms | 1 | |
Contact rating | 100mA, 250Vac | |
Alarm intervention indication | LED | |
Alarm type | MAX | |
Contact type | ||
- normally open | N.O. (cod. X...XMO) | |
- normally closed | N.C. (cod. X…XMC) | |
Alarm configuration | 10 do 120% In | |
Intevention delay | 0 do 6 s. | |
Hysteresis | 5% | |
Operating temperature | -10 +50 oC | |
Storage temperature | -30 +70oC | |
Manufactured according | IEC/EN 60044-1, VDE, BS, UTE | |
Integrated output terminals | 6 mm2 |
Type |
XAC032… |
XAC040… |
XAT061 |
XAT101 |
---|---|---|---|---|
Opening | ||||
Cable | Φ23 | Φ32 | Φ51 | |
Bar size | 32x10 mm | 40x 10 mm | 61 x 31 mm | 101x55 mm |
Pin description and diagram
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
|
RANGE (alarm range) |
XAC032… |
XAC040… |
XAT061… |
XAT101… |
---|---|---|---|---|
Code | ||||
50 A (5 to 60A) |
XAC032050XMC |
|||
100 A (10 to 120 A) |
XAC032100XMC |
|||
150 A (15 to 180A) |
XAC032150XMC |
|||
250 A (25 to 300 A) |
XAC032250XMC |
|||
400 A (40 to 480 A) |
XAC032400XMC |
XAC040400XMC |
||
600 A (60 to 720 A) |
XAC032600XMC |
XAC040600XMC |
XAT061600XMC |
|
1000 A (100 to 1200 A) |
XAC0401K0XMC |
XAT0611K0XMC |
XAT1011K0XMC |
|
1500 A (150 to 1800 A) |
XAT0611K5XMC |
XAT1011K5XMC |
||
2500 A (250 to 3000 A) |
XAT1012K5XMC |
: It is possible to set the Max. alarm threshold from10% to 120% of the current range (Example: Range=100A - Max. alarm threshold from 10A to 120A)
RANGE (alarm range) |
XAC032… |
XAC040… |
XAT061… |
XAT101… |
---|---|---|---|---|
Code | ||||
50 A (5 to 60A) |
XAC032050XMO |
|||
100 A (10 to 120 A) |
XAC032100XMO |
|||
150 A (15 to 180A) |
XAC032150XMO |
|||
250 A (25 to 300 A) |
XAC032250XMO |
|||
400 A (40 to 480 A) |
XAC032400XMO |
XAC040400XMO |
||
600 A (60 to 720 A) |
XAC032600XMO |
XAC040600XMO |
XAT061600XMO |
|
1000 A (100 to 1200 A) |
XAC0401K0XMO |
XAT0611K0XMO |
XAT1011K0XMO |
|
1500 A (150 to 1800 A) |
XAT0611K5XMO |
XAT1011K5XMO |
||
2500 A (250 to 3000 A) |
XAT1012K5XMO |
It is possible to set the Max. alarm threshold from10% to 120% of the current range (Example: Range=100A - Max. alarm threshold from 10A to 120A)
XAC032 |
XAC040 |
![]() |
![]() |
XAT061 |
XAT101 |
![]() |
![]() |
Signal alarm configuration
LED alarm signal
Normally open contact
Normally closed contact
Your review appreciation cannot be sent
Report comment
Report sent
Your report cannot be sent
Write your review
Review sent
Your review cannot be sent