Environmental protection has never been such an important issue. One of the sources of emissions of pollutants into the atmosphere are industrial plants that release harmful gases and dust during production processes. Fortunately, over the past several decades, we have reduced the negative impact of industry on the environment by implementing increasingly stringent permissible pollution concentration standards in the air.
To prevent further infiltration of harmful particles into the atmosphere, the method of electrostatic precipitation is used. This method relies on the operation of electrofilters (electrostatic filters), which remove dust, smoke, and gases.
The company DACPOL SERVICE, thanks to its many years of experience, offers professional service for high voltage power supplies in the following areas:
As a long-term service partner of the Swedish manufacturer KraftPowercon, we offer service for high voltage power supplies:
Input Voltage | 3x 380/400/415V +/-10 % |
---|---|
Frequency | 50 /60 Hz +/-5 % |
Input Current | 142/135/130 A |
Input Power | 93 kVA |
Output DC Voltage | 60 kV DC |
Output DC Current | 1000 mA |
Output Pulse Voltage | 80 kV |
Peak Voltage | 140 kV |
Pulse Length at Output | 80-90 us |
Efficiency | ≥ 94% |
IP Protection Class | CC IP31 |
Operating Temperature | -40 … +40 °C (optionally +50 °C) |
Output Voltage | 72-90 kV DC |
---|---|
Output Current | 400-1800 mA DC |
Output Power | 32-144 kW |
Input Voltage | 3x400 ± %10 V AC, |
3x400 ± %10 V AC / 3x480 ± %10 V AC, | |
3x400 ± %10 V AC | |
Frequency | 50 ± %5 Hz, |
50 ± %5 / 60 ± %5 Hz, | |
Input Power | 35-156 kW |
Input Apparent Power | 45-173 kVA |
Efficiency | > 0.93 at rated output power |
Operating Frequency | 24 kHz |
Cooling | Oil/Air |
Height | 1975 mm / 77.75 in |
Width | 826 mm / 32.5 in |
Length | 1525 mm / 60 in |
Weight | 580 Kg / 1279 lb |
Ambient Temperature | ± 40 °C |
Relative Humidity | Max 93% |
Protection Class | IP 54 |
EMC Compliance | EN 61000-6-4:2007, EN 61000-6-2:2005 |
LVD Compliance | EN 50178:1997 |
Communication Standard | RS 485 Modbus RTU |
Communication Option | Profibus-Profinet |
Primary Voltage | std 380, 400 and 415 V, |
---|---|
Other power supply voltage options: | |
220, 440, 460, 480, 500, 575, 660, 690 | |
Output Voltage | from 70 kV to 150 kV DC |
Output Current | from 100 mA to 4000 mA |
Temperature Range | -50 to +55°C, std -10 to +40 |
Primary Voltage | std 380, 400 and 415 V |
---|---|
Other power supply voltage options: | |
220, 440, 460, 480, 500, 575, 660, 690 | |
Output Voltage | from 70 kV to 150 kV DC |
Output Current | from 100 mA to 4000 mA |
Temperature Range | -50 to +55°C, std -10 to +40 |
Are you interested in this product? Do you need additional information or individual pricing?
Environmental protection has never been such an important issue. One of the sources of emissions of pollutants into the atmosphere are industrial plants that release harmful gases and dust during production processes. Fortunately, over the past several decades, we have reduced the negative impact of industry on the environment by implementing increasingly stringent permissible pollution concentration standards in the air.
To prevent further infiltration of harmful particles into the atmosphere, the method of electrostatic precipitation is used. This method relies on the operation of electrofilters (electrostatic filters), which remove dust, smoke, and gases.
The company DACPOL SERVICE, thanks to its many years of experience, offers professional service for high voltage power supplies in the following areas:
As a long-term service partner of the Swedish manufacturer KraftPowercon, we offer service for high voltage power supplies:
Input Voltage | 3x 380/400/415V +/-10 % |
---|---|
Frequency | 50 /60 Hz +/-5 % |
Input Current | 142/135/130 A |
Input Power | 93 kVA |
Output DC Voltage | 60 kV DC |
Output DC Current | 1000 mA |
Output Pulse Voltage | 80 kV |
Peak Voltage | 140 kV |
Pulse Length at Output | 80-90 us |
Efficiency | ≥ 94% |
IP Protection Class | CC IP31 |
Operating Temperature | -40 … +40 °C (optionally +50 °C) |
Output Voltage | 72-90 kV DC |
---|---|
Output Current | 400-1800 mA DC |
Output Power | 32-144 kW |
Input Voltage | 3x400 ± %10 V AC, |
3x400 ± %10 V AC / 3x480 ± %10 V AC, | |
3x400 ± %10 V AC | |
Frequency | 50 ± %5 Hz, |
50 ± %5 / 60 ± %5 Hz, | |
Input Power | 35-156 kW |
Input Apparent Power | 45-173 kVA |
Efficiency | > 0.93 at rated output power |
Operating Frequency | 24 kHz |
Cooling | Oil/Air |
Height | 1975 mm / 77.75 in |
Width | 826 mm / 32.5 in |
Length | 1525 mm / 60 in |
Weight | 580 Kg / 1279 lb |
Ambient Temperature | ± 40 °C |
Relative Humidity | Max 93% |
Protection Class | IP 54 |
EMC Compliance | EN 61000-6-4:2007, EN 61000-6-2:2005 |
LVD Compliance | EN 50178:1997 |
Communication Standard | RS 485 Modbus RTU |
Communication Option | Profibus-Profinet |
Primary Voltage | std 380, 400 and 415 V, |
---|---|
Other power supply voltage options: | |
220, 440, 460, 480, 500, 575, 660, 690 | |
Output Voltage | from 70 kV to 150 kV DC |
Output Current | from 100 mA to 4000 mA |
Temperature Range | -50 to +55°C, std -10 to +40 |
Primary Voltage | std 380, 400 and 415 V |
---|---|
Other power supply voltage options: | |
220, 440, 460, 480, 500, 575, 660, 690 | |
Output Voltage | from 70 kV to 150 kV DC |
Output Current | from 100 mA to 4000 mA |
Temperature Range | -50 to +55°C, std -10 to +40 |