Electrical heating tape for frost protection or temperature maintenance of instrument lines, pipework or vessels in safe or hazardous area environments
Description
Quintherm ILS is a super high temperature industrial/commercial grade self-regulating heating tape that can be used for super high process temperature of pipework or vessels in the pharmaceutical [&] chemical or construction industries up to 250°C (switched off) likely to be subject to steam cleaning. It can be cut-to-length on site to match exact pipe lengths without any complicated design considerations.
ILS is approved for use in non-hazardous, hazardous or corrosive environments to world-wide standards.
Its self-regulating characteristics improve safety and reliability. ILS will not overheat or burnout, even if overlapped upon itself. Its power output is automatically self-regulated in response to pipe or heating surface temperature. This ensures safety and reliability.
Installation of ILS is quick and easy, requiring no special tools or skills. Terminations, in-line splicing and power connection components are all available in convenient kits.
Available Options
ILS../Qx Base heating tape without any braiding or outerjacket (for non-Ex applications only) (available upon special request)
ILS..N/Qx Base heating tape with nickel-plated copper braid providing mechanical protection or where traced equipment does not provide an effective earth path, e.g. plastic or non-metallic pipework or surfaces. (available upon special request)
ILS..NF/Qx Base heating tape with nickel-plated copper braid and
fluoropolymer outerjacket for added mechanical and aggressive
chemical protection.
Technical Data
Max. Allowed Exposure Temperature: Power ON: Power OFF: |
|
220°C 250°C |
|
Min. Installation Temperature: | -40OC |
Min. Operating Temperature: | -65OC |
Power Supply: | 220-277V AC |
Temperature Class: | T3 = up to [&] incl. ILS60.. T2 = ILS75= and ILSw100= |
Max. Resistance of Protective Braiding: | ≤18,2 Ω/km |
Type | Dimensions Nominal (mm) | Weight kg/100 m | Min. Bending Radius (mm) | Gland Size |
---|---|---|---|---|
ILS.. | 10,2 x 3,5 | 7,6 | 20 | M20 |
ILS..N | 11,2 x 4,5 | 11,3 | 30 | M20 |
ILS..NF | 12,1 x 5,4 | 14,6 | 35 | M20 |
ILSw.. | 12,5 x 3,7 | 11,4 | 25 | M25 |
ILSw..N | 13,5 x 4,7 | 15,8 | 30 | M25 |
ILSw..NF | 14,4 x 5,6 | 19,5 | 35 | M25 |
Nominal Power Output at 230V when ILS is installed on thermally insulated carbon steel pipes.
Max. Cct Length (m) vs. MCB Size (A)
Type | Start-up Temp. |
10A | 16A | 20A | 25A |
---|---|---|---|---|---|
ILS152.. | 10°C | 76 | 122 | 154 | 154 |
0°C | 70 | 112 | 140 | 146 | |
-20°C | 62 | 98 | 122 | 138 | |
-40°C | 52 | 82 | 102 | 126 | |
ILS302.. | 10°C | 52 | 82 | 102 | 108 |
0°C | 46 | 74 | 92 | 104 | |
-20°C | 40 | 66 | 82 | 98 | |
-40C | 30 | 50 | 62 | 88 | |
ILS452... | 10°C | 38 | 62 | 76 | 88 |
0°C | 32 | 52 | 66 | 84 | |
-20°C | 24 | 38 | 46 | 76 | |
-40°C | 14 | 24 | 28 | 46 | |
ILS602.. | 10°C | 24 | 38 | 46 | 76 |
0°C | 18 | 30 | 36 | 58 | |
-20°C | 12 | 20 | 26 | 42 | |
-40°C | 8 | 12 | 16 | 24 | |
ILS752.. | 10°C | 14 | 24 | 24 | 46 |
0°C | 12 | 18 | 18 | 36 | |
-20°C | 8 | 12 | 12 | 24 | |
-40°C | 4 | 8 | 8 | 14 | |
ILS902.. | 10°C | 20 | 20 | 23 | 38 |
0°C | 15 | 15 | 18 | 30 | |
-20°C | 10 | 10 | 13 | 20 | |
-40°C | 6 | 6 | 2 | 11 | |
ILSw1202.. | 10°C | 22 | 22 | 28 | 46 |
0°C | 18 | 18 | 24 | 36 | |
-20°C | 14 | 14 | 16 | 26 | |
-40°C | 10 | 10 | 12 | 20 |
Accessories
A full range of accessories are available to compliment our heating tapes, such as terminations, end seals, junction boxes and thermostats. Most items carry separate approvals where required for use in hazardous areas.
Are you interested in this product? Do you need additional information or individual pricing?
Electrical heating tape for frost protection or temperature maintenance of instrument lines, pipework or vessels in safe or hazardous area environments
Description
Quintherm ILS is a super high temperature industrial/commercial grade self-regulating heating tape that can be used for super high process temperature of pipework or vessels in the pharmaceutical [&] chemical or construction industries up to 250°C (switched off) likely to be subject to steam cleaning. It can be cut-to-length on site to match exact pipe lengths without any complicated design considerations.
ILS is approved for use in non-hazardous, hazardous or corrosive environments to world-wide standards.
Its self-regulating characteristics improve safety and reliability. ILS will not overheat or burnout, even if overlapped upon itself. Its power output is automatically self-regulated in response to pipe or heating surface temperature. This ensures safety and reliability.
Installation of ILS is quick and easy, requiring no special tools or skills. Terminations, in-line splicing and power connection components are all available in convenient kits.
Available Options
ILS../Qx Base heating tape without any braiding or outerjacket (for non-Ex applications only) (available upon special request)
ILS..N/Qx Base heating tape with nickel-plated copper braid providing mechanical protection or where traced equipment does not provide an effective earth path, e.g. plastic or non-metallic pipework or surfaces. (available upon special request)
ILS..NF/Qx Base heating tape with nickel-plated copper braid and
fluoropolymer outerjacket for added mechanical and aggressive
chemical protection.
Technical Data
Max. Allowed Exposure Temperature: Power ON: Power OFF: |
|
220°C 250°C |
|
Min. Installation Temperature: | -40OC |
Min. Operating Temperature: | -65OC |
Power Supply: | 220-277V AC |
Temperature Class: | T3 = up to [&] incl. ILS60.. T2 = ILS75= and ILSw100= |
Max. Resistance of Protective Braiding: | ≤18,2 Ω/km |
Type | Dimensions Nominal (mm) | Weight kg/100 m | Min. Bending Radius (mm) | Gland Size |
---|---|---|---|---|
ILS.. | 10,2 x 3,5 | 7,6 | 20 | M20 |
ILS..N | 11,2 x 4,5 | 11,3 | 30 | M20 |
ILS..NF | 12,1 x 5,4 | 14,6 | 35 | M20 |
ILSw.. | 12,5 x 3,7 | 11,4 | 25 | M25 |
ILSw..N | 13,5 x 4,7 | 15,8 | 30 | M25 |
ILSw..NF | 14,4 x 5,6 | 19,5 | 35 | M25 |
Nominal Power Output at 230V when ILS is installed on thermally insulated carbon steel pipes.
Max. Cct Length (m) vs. MCB Size (A)
Type | Start-up Temp. |
10A | 16A | 20A | 25A |
---|---|---|---|---|---|
ILS152.. | 10°C | 76 | 122 | 154 | 154 |
0°C | 70 | 112 | 140 | 146 | |
-20°C | 62 | 98 | 122 | 138 | |
-40°C | 52 | 82 | 102 | 126 | |
ILS302.. | 10°C | 52 | 82 | 102 | 108 |
0°C | 46 | 74 | 92 | 104 | |
-20°C | 40 | 66 | 82 | 98 | |
-40C | 30 | 50 | 62 | 88 | |
ILS452... | 10°C | 38 | 62 | 76 | 88 |
0°C | 32 | 52 | 66 | 84 | |
-20°C | 24 | 38 | 46 | 76 | |
-40°C | 14 | 24 | 28 | 46 | |
ILS602.. | 10°C | 24 | 38 | 46 | 76 |
0°C | 18 | 30 | 36 | 58 | |
-20°C | 12 | 20 | 26 | 42 | |
-40°C | 8 | 12 | 16 | 24 | |
ILS752.. | 10°C | 14 | 24 | 24 | 46 |
0°C | 12 | 18 | 18 | 36 | |
-20°C | 8 | 12 | 12 | 24 | |
-40°C | 4 | 8 | 8 | 14 | |
ILS902.. | 10°C | 20 | 20 | 23 | 38 |
0°C | 15 | 15 | 18 | 30 | |
-20°C | 10 | 10 | 13 | 20 | |
-40°C | 6 | 6 | 2 | 11 | |
ILSw1202.. | 10°C | 22 | 22 | 28 | 46 |
0°C | 18 | 18 | 24 | 36 | |
-20°C | 14 | 14 | 16 | 26 | |
-40°C | 10 | 10 | 12 | 20 |