

Category
Photos are for informational purposes only. View product specification
please use latin characters
The PCOB-245T1 generator has been specially designed to simulate conditions occurring during EMC disturbances and in line with electromagnetic compatibility requirements: surge immunity test (SUG), fast transient group impulse immunity test, and electrostatic discharge (ESD) immunity test. The device is used to assess the performance of power cables as well as internal connecting wires in electrical and electronic equipment when subjected to high-energy disturbances caused by transients and natural atmospheric discharges. Measurement results can serve as a starting point for assessing the performance of power ports, signal ports, control ports, and grounding in electrical equipment when subjected to fast transient impulse disturbances (EFT). The measurements also allow for the evaluation of the performance of electrically powered equipment when subjected to electrostatic discharge disturbances directly by operators and adjacent objects.
Features
PCOB-245T1 | ||
Model | ||
ESD | ||
Output Voltage | 0.2~± 20 kV ± 5% Positive/Negative | |
Test Functions | Contact Discharge / Air Discharge | |
Operating Mode | Interval 0.05 ~99.99 s, Form discharge testing 20PPS; Setting below 0.05 s is called a single discharge. |
|
Capacitor /Discharge Resistor |
150pF /330 Ω (optional) | |
Rise Time | 0.7 ~ 1ns | |
Output Voltage | 500~± 5000V ± 10%, Positive/Negative/Selectable | |
Pulse Frequency | 1kHz~1200kHz ± 10%, on request | |
Resistor | 50 Ω± 20% | |
Rise Time | 5ns ± 30% | |
EFT | ||
Pulse Duration | 50 Ω load | 50ns ± 30% | |
Disturbance Count | 1k Ω load | 35 ns~150 ns | |
Disturbance Time | 1~255 | |
Open Circuit Voltage, Short Circuit Current | 300mS ( 0.15~9.99 S on request,step 0.01S ) | |
SUG | ||
Polarization | Open circuit voltage: 1.2/50 μs 0.5~ 6Kv ± 10%, | |
Phase | Short circuit current 8 /20 μ s ,0.25~ 3kA ± 10%, | |
Output Impedance | Positive/Negative/Selectable | |
Surge Count | Synchronization 0 °~ 360 °selectable/Asynchronous | |
Surge Interval | Impedance: 2 Ω 12 Ω | |
Coupling | 1~9999 | |
Surge Interval | 10~9999s | |
Coupling Path | Integrated, single-phase triple AC/DC 240V line, 16A | |
Operating Power | AC220V 50/60Hz |
Are you interested in this product? Do you need additional information or individual pricing?
The PCOB-245T1 generator has been specially designed to simulate conditions occurring during EMC disturbances and in line with electromagnetic compatibility requirements: surge immunity test (SUG), fast transient group impulse immunity test, and electrostatic discharge (ESD) immunity test. The device is used to assess the performance of power cables as well as internal connecting wires in electrical and electronic equipment when subjected to high-energy disturbances caused by transients and natural atmospheric discharges. Measurement results can serve as a starting point for assessing the performance of power ports, signal ports, control ports, and grounding in electrical equipment when subjected to fast transient impulse disturbances (EFT). The measurements also allow for the evaluation of the performance of electrically powered equipment when subjected to electrostatic discharge disturbances directly by operators and adjacent objects.
Features
PCOB-245T1 | ||
Model | ||
ESD | ||
Output Voltage | 0.2~± 20 kV ± 5% Positive/Negative | |
Test Functions | Contact Discharge / Air Discharge | |
Operating Mode | Interval 0.05 ~99.99 s, Form discharge testing 20PPS; Setting below 0.05 s is called a single discharge. |
|
Capacitor /Discharge Resistor |
150pF /330 Ω (optional) | |
Rise Time | 0.7 ~ 1ns | |
Output Voltage | 500~± 5000V ± 10%, Positive/Negative/Selectable | |
Pulse Frequency | 1kHz~1200kHz ± 10%, on request | |
Resistor | 50 Ω± 20% | |
Rise Time | 5ns ± 30% | |
EFT | ||
Pulse Duration | 50 Ω load | 50ns ± 30% | |
Disturbance Count | 1k Ω load | 35 ns~150 ns | |
Disturbance Time | 1~255 | |
Open Circuit Voltage, Short Circuit Current | 300mS ( 0.15~9.99 S on request,step 0.01S ) | |
SUG | ||
Polarization | Open circuit voltage: 1.2/50 μs 0.5~ 6Kv ± 10%, | |
Phase | Short circuit current 8 /20 μ s ,0.25~ 3kA ± 10%, | |
Output Impedance | Positive/Negative/Selectable | |
Surge Count | Synchronization 0 °~ 360 °selectable/Asynchronous | |
Surge Interval | Impedance: 2 Ω 12 Ω | |
Coupling | 1~9999 | |
Surge Interval | 10~9999s | |
Coupling Path | Integrated, single-phase triple AC/DC 240V line, 16A | |
Operating Power | AC220V 50/60Hz |
Your review appreciation cannot be sent
Report comment
Report sent
Your report cannot be sent
Write your review
Review sent
Your review cannot be sent