KEW 6305 Multifunctional portable power and energy analyzer
  • KEW 6305 Multifunctional portable power and energy analyzer

Photos are for informational purposes only. View product specification

please use latin characters

Manufacturer: Kyoritsu

KEW 6305 Multifunctional portable power and energy analyzer

KEW 6305 Compact Power Meter

  • Comprehensive real-time monitoring, recording and analysis of single and 3-phase systems
  • Voltage, Current, Power Factor and Frequency measurements
  • Power analysis (Active, Apparent and Reactive power)
  • Energy analysis (Active, Apparent and Reactive power)
  • Active power accuracy: ±0.3%rdg±0.2%f.s.
  • Automatic wiring check function to prevent incorrect connections
  • Large memory capability (2GB) using built-in SD card interface
  • Real time [&] remote measurements using Android application
  • synchronous measurements between two units of KEW 6305
  • Wide selection of clamp sensors allow measurements from 0.1A to 3000A
  • The instrument automatically recognizes what kind of clamp sensor is connected to it 6305 CE
  • Windows software for data analysis and setting via USB port or Bluetooth

 
Wiring connections 1P2W, 1P3W, 3P3W, 3P3W3A, 3P4W
Measurements Voltage, Current, Frequency, Active power
Parameters Apparent power, Reactive power, Active energy, Apparent energy, Reactive energy, Power factor (cos 8), Neutral current
Voltage range 150.0/300.0/600.0V
Voltage accuracy ±0.2%rdg±0.2%f.s. (sine wave, 45~65Hz)
Current range 10.00/50.00/100.0/250.0/500.0A/Auto (with clamp sensor MODEL8125)
Current accuracy ±0.2%rdg±0.2%f.s.+ Accuracy of Clamp sensor (sine wave, 45—65Hz) *+1%f.s. at the lowest range.
Effective input range 10—110% of rating range
Display range 5~130% of each range (Voltage) 1—130% of each range (Current)
Crest factor Voltage : up to 2.5, Current : up to 3.0 (with 90% fs or less)
Active power accuracy ±0.3%rdg±0.2%f.s.+ Accuracy of Clamp sensor *+1%f.s. when the lowest current ranges is selected.
Effect of power factor Active power: ±1.0%rdg cos 8=±0.5 (PF=1)
Frequency meter range 40.0—70.0Hz
Frequency meter accuracy ±3dgt
Accuracy precondition PF=1, Sine wave, 45—65Hz, 23'C±5'C
Display update period 1 second
Operating temperature and humidity range 0—+50C, less than 85% RH (without condensation)
Storage temperature and humidity range -20—+60C, less than 85% RH (without condensation)
PC communication interface USB, Bluetooth
PC card interface SD card (2GB)
Safety standard IEC61010-1 CAT.m 600V
Power supply (AC Line) AC100—240V±10%(50/60Hz)
Power supply (DC battery) LR6 or Ni-MH(HR-15-51)x6 (Battery charger not included), Battery life approx. 15h (LR6)
Power consumption 10VA (max.)
Dimension Weight 175(L)x120(W)x65(D)mm Approx. 800g (including batteries)
Included accessories 7141B (Voltage test lead set: 4pcs), 7148 (USB cable), 7170(Powercord), 9125(Carrying case), 8326-02 (SD card 2GB), KEW WINDOWS (PC Software), Battery(LR6)x6, Quick manual, Calibration certificate
Optional accessories 8124, 8125, 8126, 8127, 8128 (Clamp sensor), 8129 (Flexible clamp sensor), 8312 (Power supply adaptor), 9132 (Magnetic carrying case)

Send an inquiry

Are you interested in this product? Do you need additional information or individual pricing?

Contact us
ASK FOR THE PRODUCT close
Thank you for sending your message. We will respond as soon as possible.
ASK FOR THE PRODUCT close
Browse

Add to Wishlist

You must be logged in

KEW 6305 Compact Power Meter

  • Comprehensive real-time monitoring, recording and analysis of single and 3-phase systems
  • Voltage, Current, Power Factor and Frequency measurements
  • Power analysis (Active, Apparent and Reactive power)
  • Energy analysis (Active, Apparent and Reactive power)
  • Active power accuracy: ±0.3%rdg±0.2%f.s.
  • Automatic wiring check function to prevent incorrect connections
  • Large memory capability (2GB) using built-in SD card interface
  • Real time [&] remote measurements using Android application
  • synchronous measurements between two units of KEW 6305
  • Wide selection of clamp sensors allow measurements from 0.1A to 3000A
  • The instrument automatically recognizes what kind of clamp sensor is connected to it 6305 CE
  • Windows software for data analysis and setting via USB port or Bluetooth

 
Wiring connections 1P2W, 1P3W, 3P3W, 3P3W3A, 3P4W
Measurements Voltage, Current, Frequency, Active power
Parameters Apparent power, Reactive power, Active energy, Apparent energy, Reactive energy, Power factor (cos 8), Neutral current
Voltage range 150.0/300.0/600.0V
Voltage accuracy ±0.2%rdg±0.2%f.s. (sine wave, 45~65Hz)
Current range 10.00/50.00/100.0/250.0/500.0A/Auto (with clamp sensor MODEL8125)
Current accuracy ±0.2%rdg±0.2%f.s.+ Accuracy of Clamp sensor (sine wave, 45—65Hz) *+1%f.s. at the lowest range.
Effective input range 10—110% of rating range
Display range 5~130% of each range (Voltage) 1—130% of each range (Current)
Crest factor Voltage : up to 2.5, Current : up to 3.0 (with 90% fs or less)
Active power accuracy ±0.3%rdg±0.2%f.s.+ Accuracy of Clamp sensor *+1%f.s. when the lowest current ranges is selected.
Effect of power factor Active power: ±1.0%rdg cos 8=±0.5 (PF=1)
Frequency meter range 40.0—70.0Hz
Frequency meter accuracy ±3dgt
Accuracy precondition PF=1, Sine wave, 45—65Hz, 23'C±5'C
Display update period 1 second
Operating temperature and humidity range 0—+50C, less than 85% RH (without condensation)
Storage temperature and humidity range -20—+60C, less than 85% RH (without condensation)
PC communication interface USB, Bluetooth
PC card interface SD card (2GB)
Safety standard IEC61010-1 CAT.m 600V
Power supply (AC Line) AC100—240V±10%(50/60Hz)
Power supply (DC battery) LR6 or Ni-MH(HR-15-51)x6 (Battery charger not included), Battery life approx. 15h (LR6)
Power consumption 10VA (max.)
Dimension Weight 175(L)x120(W)x65(D)mm Approx. 800g (including batteries)
Included accessories 7141B (Voltage test lead set: 4pcs), 7148 (USB cable), 7170(Powercord), 9125(Carrying case), 8326-02 (SD card 2GB), KEW WINDOWS (PC Software), Battery(LR6)x6, Quick manual, Calibration certificate
Optional accessories 8124, 8125, 8126, 8127, 8128 (Clamp sensor), 8129 (Flexible clamp sensor), 8312 (Power supply adaptor), 9132 (Magnetic carrying case)
Comments (0)