BackX
-
Components
-
-
Category
-
Semiconductors
- Diodes
- Thyristors
-
Electro-insulated Modules
- Electro-insulated Modules | VISHAY (IR)
- Electro-insulated Modules | INFINEON (EUPEC)
- Electro-insulated Modules | Semikron
- Electro-insulated Modules | POWEREX
- Electro-insulated Modules | IXYS
- Electro-insulated Modules | POSEICO
- Electro-insulated Modules | ABB
- Electro-insulated Modules | TECHSEM
- Go to the subcategory
- Bridge Rectifiers
-
Transistors
- Transistors | GeneSiC
- SiC MOSFET Modules | Mitsubishi
- SiC MOSFET Modules | STARPOWER
- Module SiC MOSFET ABB’s
- IGBT Modules | MITSUBISHI
- Transistor Modules | MITSUBISHI
- MOSFET Modules | MITSUBISHI
- Transistor Modules | ABB
- IGBT Modules | POWEREX
- IGBT Modules | INFINEON (EUPEC)
- Silicon Carbide (SiC) semiconductor elements
- Go to the subcategory
- Gate Drivers
- Power Blocks
- Go to the subcategory
- Electrical Transducers
-
Passive components (capacitors, resistors, fuses, filters)
- Resistors
-
Fuses
- Miniature Fuses for electronic circuits - ABC & AGC Series
- Tubular Fast-acting Fuses
- Time-delay Fuse Links with GL/GG & AM characteristics
- Ultrafast Fuse Links
- Fast-acting Fuses (British & American standard)
- Fast-acting Fuses (European standard)
- Traction Fuses
- High-voltage Fuse Links
- Go to the subcategory
- Capacitors
- EMI Filters
- Supercapacitors
- Power surge protection
- Go to the subcategory
-
Relays and Contactors
- Relays and Contactors - Theory
- 3-Phase AC Semiconductor Relays
- DC Semiconductor Relays
- Controllers, Control Systems and Accessories
- Soft Starters and Reversible Relays
- Electromechanical Relays
- Contactors
- Rotary Switches
-
Single-Phase AC Semiconductor Relays
- AC ONE PHASE RELAYS 1 series| D2425 | D2450
- One phase semiconductor AC relays CWA and CWD series
- One phase semiconductor AC relays CMRA and CMRD series
- One phase semiconductor AC relays - PS series
- Double and quadruple semiconductor AC relays - D24 D, TD24 Q, H12D48 D series
- One phase semiconductor relays - gn series
- Ckr series single phase solid state relays
- One phase AC semiconductor relays for DIN bus - ERDA I ERAA series
- 150A AC single phase relays
- Rail Mountable Solid State Relays With Integrated Heat Sink - ENDA, ERDA1 / ERAA1 series
- Go to the subcategory
- Single-Phase AC Semiconductor Relays for PCBs
- Interface Relays
- Go to the subcategory
- Cores and Other Inductive Components
- Heatsinks, Varistors, Thermal Protection
- Fans
- Air Conditioning, Accessories for Electrical Cabinets, Coolers
-
Batteries, Chargers, Buffer Power Supplies and Inverters
- Batteries, Chargers - Theoretical Description
- Modular Li-ion Battery Building Blocks, Custom Batteries, BMS
- Batteries
- Battery Chargers and Accessories
- Uninterruptible Power Supply and Buffer Power Supplies
- Inverters and Photovoltaic Equipments
- Energy storage
- Fuel cells
- Lithium-ion batteries
- Go to the subcategory
-
Automatics
- Futaba Drone Parts
- Limit Switches, Microswitches
- Sensors, Transducers
-
Infrared Thermometers (Pyrometers)
- IR-TE Series - Water-proof Palm-sized Radiation Thermometer
- IR-TA Series - Handheld Type Radiation Thermometer
- IR-H Series - Handheld Type Radiation Thermometer
- IR-BA Series - High-speed Compact Radiation Thermometer
- IR-FA Series - Fiber Optic Radiation Thermometer
- IR-BZ Series - Compact Infrared Thermometers
- Go to the subcategory
- Counters, Time Relays, Panel Meters
- Industrial Protection Devices
- Light and Sound Signalling
- Thermographic Camera
- LED Displays
- Control Equipments
-
Recorders
- Hybrid Recorders - AL3000 Series | CHINO
- Graphic Recorder - KR2000 Series | CHINO
- Ubiquitous Recorders - KR5000 Series | CHINO
- Palm-sized Temperature/Humidity Meters - HN-CH Series | CHINO
- Consumables for Recorders
- 71VR1 - Compact Paperless Recorder | M-SYSTEM
- Graphic Recorder - KR3000 Series | CHINO
- PC Recorders - R1M Series | M-SYSTEM
- PC Recorders - R2M Series | M-SYSTEM
- PC Recorders - RZMS Series | M-SYSTEM
- PC Recorders - RZUS Series | M-SYSTEM
- Go to the subcategory
- Go to the subcategory
-
Cables, Litz wires, Conduits, Flexible connections
- Wires
- Litz wires
- Cables for extreme applications
- Sleevings
-
Braids
- Flat Braids
- Round Braids
- Very Flexible Flat Braids
- Very Flexible Round Braids
- Cylindrical Cooper Braids
- Cylindrical Cooper Braids and Sleevings
- Flexible Earthing Connections
- Galvanized and Stainless Steel Cylindrical Braids
- PCV Insulated Copper Braids (temp. up to 85C)
- Flat Aluminium Braids
- Junction Set - Braids and Tubes
- Go to the subcategory
- Traction Equipment
- Cable Terminals
- Flexible Insulated Busbars
- Flexible Multilayer Busbars
- Cable Duct Systems
- Hoses
- Go to the subcategory
- View all categories
-
Semiconductors
-
-
- Suppliers
-
Applications
- CNC Machine Tools
- DC and AC Drives (Inverters)
- Energetics
- Energy bank
- Equipment and Components for Hazardous Areas [Ex]
- Equipment for Distribution, Control and Telecommunications Cabinets
- HVAC Automation
- Induction Heating
- Industrial Automation
- Industrial Protective Devices
- Machines for Drying and Wood Processing
- Machines for Thermoforming Plastics
- Mining, Metallurgy and Foundry
- Motors and Transformers
- Power Supplies (UPS) and Rectifier Systems
- Printing
- Temperature Measurement and Regulation
- Test and Laboratory Measurements
- Tram and Railway Traction
- Welding Machines
-
Assembly
-
-
Montaż urządzeń
- Assembly of equipment on request
- Designing and Assembling of Busbar Cabinets, Switching Cabinets, Power Cabinets
- Power systems installation
- Components
- Machines built for order
- R&D research and development work
-
Industrial Testers
- Tester for diodes and thyristors measurement
- Thermal and motor circuit breakers testing stand
- Varistors and surge protectors testers
- Car fuses testing stand
- Tester for the power diode and thyristor reverse recovery charge Qrr measurement
- Rotor tester FD series
- Circuit breakers tester
- Tester for calibrating relays
- Video inspection tester for gas spring piston rods
- High-current thyristor switch
- Mesh ripping tester
- Go to the subcategory
- View all categories
-
-
-
Inductors
-
-
Modernizacja induktorów
- Repair of used inductors
- Modernization of inductors
-
Production of new inductors
- Inductors for crankshaft hardening
- Hardening of band saw teeth
- Inductors for heating elements before gluing
- Hardening of raceways of automotive wheel hub bearings
- Hardening of the drive transmission components
- Hardening of stepped shafts
- Heating in contraction joints
- Induction for scanning hardening
- Soft soldering
- Billet heaters
- Go to the subcategory
- Knowledge base
- View all categories
-
-
-
Induction devices
-
-
Urządzenia indukcyjne
-
Induction heating generators
-
Induction Heating Products Ambrell
- Generators power 500 W, frequency 150 - 400 kHz
- Generators power 1.2 - 2.4 kW, frequency 150 - 400 kHz
- Generators power 4.2 - 10 kW, frequency 150 - 400 kHz
- Generators power 10-15 kW, frequency 50-150 kHz
- Generators power 30-45 kW, frequency 50-150 kHz
- Generators power 65-135 kW, frequency 50-150 kHz
- Generators power 180-270 kW, frequency 50-150 kHz
- Generators power 20-35-50 kW, frequency 15-45 kHz
- Generators power 75-150 kW, frequency 15-45 kHz
- Generators power 200-500 kW, frequency 15-45 kHz
- Generators power 20-50 kW, frequency 5-15 kHz
- Go to the subcategory
- Induction heating products Denki Kogyo
-
JKZ induction heating generators
- Generators CX, frequency: 50-120kHz, power: 5-25kW
- Generators SWS, frequency: 15-30kHz, power: 25-260kW
- Molding and forging furnaces MFS, frequency: 0,5-10kHz, power: 80-500kW
- Melting metals furnaces MFS, frequency: 0,5-10kHz, power: 70-200kW
- Generators UHT, frequency: 200-400kHz, power: 10-160kW
- Go to the subcategory
- Lamp generators for induction heating
- Induction Heating Products - Himmelwerk
- Go to the subcategory
-
Induction Heating Products Ambrell
- Repairs and modernization
- Peripherals
-
Applications
- Medical Applications with Precision Induction Heating
- Applications for automotive industry
- Soldering
- Brazing
- Aluminum Brazing
- Brazing a magnetic steel cutting tool
- Pin Sealing
- Atmospheric Brazing
- Soldering brass and steel radiator caps
- Carbide Tipping
- Soldering a copper lug and a wire
- Go to the subcategory
- Knowledge base
- View all categories
-
Induction heating generators
-
-
-
Service
-
-
asd
- Service of industrial water coolers and air conditioners
- Machines Repairs and Modernizations
- Repair and Maintenance of Power Electronics, Electronic and Industrial Automation Devices
- HV Power Supplies for Electrostatic Precipitators
- Industrial Printers and Labelling Machines
- Certificates / Entitlements
- View all categories
-
-
- Contact
- Zobacz wszystkie kategorie
Measures (preventive) of explosion protection

W wielu przypadkach uniknięcie atmosfer wybuchowych i źródeł zapłonu nie jest możliwe w sposób pewny. Należy zatem podjąć odpowiednie środki, aby ograniczyć skutki wybuchu do dopuszczalnych rozmiarów.
Takimi środkami są:
- konstrukcje odporne na wybuchy;
- ujścia wybuchu;
- tłumienie wybuchu;
- zapobieganie rozprzestrzenianiu się płomieni i wybuchów.
Wymienione środki odnoszą się głównie do ograniczania niebezpiecznych skutków wybuchów rozpoczynających się w instalacjach. Urządzenia i systemy ochronne, które spełniają wymagania dyrektywy 94/9/WE są zwykle wykorzystywane jako środki ograniczające. Środki strukturalne, np.: filary ochronne, mogą zostać również podjęte.
Urządzenia odporne na wybuch
Elementy instalacji, takie jak pojemniki, naczynia i przewody rurowe, są tak skonstruowane, że mogą wytrzymać wewnętrzny wybuch bez rozerwania. Ciśnienie początkowe w elemencie instalacji musi zostać uwzględnione, jeżeli różni się od normalnego ciśnienia atmosferycznego.Ogólnie, stosuje się rozróżnienie pomiędzy rodzajami konstrukcji odpornymi na wybuch.
- konstrukcje odporne na maksymalne nadciśnienie wybuchu;
- konstrukcje odporne na zmniejszone nadciśnienie wybuchu związane z ujściem wybuchu lub tłumieniem wybuchu.
Ujście wybuchu
W szerokim tego słowa znaczeniu „ujście wybuchu” obejmuje wszystkie środki umożliwiające, w przypadku dojścia do wybuchu lub jego rozprzestrzenienia się do pewnego stopnia, krótkie lub trwałe otwarcie, w kierunku nie powodującym zagrożenia, zamkniętej instalacji, w której doszło do wybuchu, w momencie gdy osiągnięte jest ciśnienie uruchamiające urządzenie umożliwiające ujście wybuchu. Zadaniem urządzenia umożliwiającego ujście wybuchu jest zapewnienie, iż instalacja nie jest zagrożona wybuchem przekraczającym jej wytrzymałość. Wynikiem tego działania jest zmniejszone nadciśnienie wybuchu.Przykładowe urządzenia umożliwiające ujście wybuchu.
Przykładem urządzeń, które mogą być używane jako „urządzenia umożliwiające ujście wybuchu” mogą być membrany bezpieczeństwa i zawory przeciwwybuchowe. Parametry mieszaniny związane z bezpieczeństwem muszą być określone aby obliczyć niezbędną powierzchnię ujścia dla instalacji. Ujście wybuchu nie jest dopuszczalne jeżeli może spowodować emisję substancji zagrażających ludziom lub środowisku (np. emisja substancji toksycznych).
Tłumienie wybuchu
Systemy tłumienia wybuchu zapobiegają osiągnięciu maksymalnego ciśnienia wybuchu poprzez szybkie wprowadzenie środków gaśniczych do pojemników i instalacji w przypadku wybuchu. Elementy chronione w ten sposób muszą być tak skonstruowane, aby wytrzymały jedynie zmniejszone ciśnienie wybuchu. W odróżnieniu do ujścia wybuchu, zapewnia to zatrzymanie skutków wybuchu wewnątrz pojemnika. W zależności od konstrukcji, nadciśnienie wybuchu może zostać zmniejszone do 0,2 bara.
Zapobieganie rozprzestrzenianiu się wybuchów (techniczne odłączanie)
Wybuch, do którego doszło w jednej części instalacji może rozprzestrzenić się w górnych lub dolnych częściach, w których może spowodować dalsze wybuchy. Efekt przyspieszenia spowodowany przez elementy instalacji lub rozprzestrzenianie się w przewodach rurowych może zintensyfikować skutki wybuchu. Powstałe w ten sposób ciśnienie wybuchu może być dużo wyższe niż maksymalne ciśnienie wybuchu w normalnych warunkach oraz może zniszczyć elementy instalacji, nawet jeżeli ich konstrukcja jest odporna na ciśnienie wybuchu lub uderzenie ciśnienia wybuchu. Dlatego też ważnym jest ograniczenie prawdopodobnego wybuchu do pojedynczych elementów instalacji. Można to osiągnąć poprzez techniczne odłączenie przeprowadzone w drodze:
- mechanicznej izolacji o szybkim działaniu;
- gaszenia płomieni w wąskich szczelinach lub poprzez wprowadzenie środka gaśniczego;
- zatrzymania płomieni przy zastosowaniu silnego przeciwprądu;
- zamknięcia wodnego;
- zaworów obrotowych.
Opisane powyżej środki ochrony przeciwwybuchowej są utrzymywane w gotowości, monitorowane i uruchamiane przez urządzenia zabezpieczające, sterujące i regulacyjne. Ogólnie, urządzenia SSP mogą być używane aby zapobiegać pojawieniu się niebezpiecznych atmosfer wybuchowych lub źródeł zapłonu lub aby ograniczać szkodliwe skutki wybuchu. Potencjalne źródła zapłonu, takie jak gorące powierzchnie, mogą być monitorowane przez urządzenia SSP i kontrolowane tak aby bezpieczna wartość nie została przekroczona.
Potencjalne źródła zapłonu mogą zostać również wyłączone w przypadku pojawienia się niebezpiecznej atmosfery wybuchowej. Na przykład urządzenie nieodporne na wybuch może zostać wyłączone, w przypadku uruchomienia wykrywacza gazu, jeżeli zapobiega to pojawieniu się potencjalnych źródeł zapłonu wewnątrz urządzenia. Można zapobiec pojawieniu się niebezpiecznych atmosfer wybuchowych, np. poprzez uruchomienie wentylatora przed osiągnięciem maksymalnego dopuszczalnego stężenia gazu.
Zastosowanie urządzeń SSP może zmniejszyć rozmiar stref Ex oraz zapobiec lub ograniczyć prawdopodobieństwo wystąpienia niebezpiecznej atmosfery wybuchowej. Urządzenia SSP w połączeniu z systemami służącymi do ograniczania szkodliwych skutków wybuchu stanowią systemy ochronne jak choćby systemy tłumienia wybuchów. Projektowanie i zasięg wymienionych urządzeń SSP oraz środki uruchamiane przez nie zależą od prawdopodobieństwa pojawienia się niebezpiecznych atmosfer wybuchowych oraz efektywnych źródeł zapłonu. Niezawodność urządzeń SSP w połączeniu z podjętym środkami technicznymi i organizacyjnymi musi zapewnić ograniczenie niebezpieczeństwa wybuchu do dopuszczalnego poziomu we wszystkich warunkach funkcjonowania. W niektórych przypadkach, przydatne mogłoby być połączenie urządzeń SSP do zapobieganiu źródłom zapłonu z urządzeniami SSP służącymi zapobieganiu niebezpiecznych atmosfer wybuchowych.