-
BackX
-
Components
-
-
Category
-
Semiconductors
- Diodes
- Thyristors
-
Electro-insulated Modules
- Electro-insulated Modules | VISHAY (IR)
- Electro-insulated Modules | INFINEON (EUPEC)
- Electro-insulated Modules | Semikron
- Electro-insulated Modules | POWEREX
- Electro-insulated Modules | IXYS
- Electro-insulated Modules | POSEICO
- Electro-insulated Modules | ABB
- Electro-insulated Modules | TECHSEM
- Go to the subcategory
- Bridge Rectifiers
-
Transistors
- Transistors | GeneSiC
- SiC MOSFET Modules | Mitsubishi
- SiC MOSFET Modules | STARPOWER
- Module SiC MOSFET ABB’s
- IGBT Modules | MITSUBISHI
- Transistor Modules | MITSUBISHI
- MOSFET Modules | MITSUBISHI
- Transistor Modules | ABB
- IGBT Modules | POWEREX
- IGBT Modules | INFINEON (EUPEC)
- Silicon Carbide (SiC) semiconductor elements
- Go to the subcategory
- Gate Drivers
- Power Blocks
- Go to the subcategory
- Electrical Transducers
-
Passive components (capacitors, resistors, fuses, filters)
- Resistors
-
Fuses
- Miniature Fuses for electronic circuits - ABC & AGC Series
- Tubular Fast-acting Fuses
- Time-delay Fuse Links with GL/GG & AM characteristics
- Ultrafast Fuse Links
- Fast-acting Fuses (British & American standard)
- Fast-acting Fuses (European standard)
- Traction Fuses
- High-voltage Fuse Links
- Go to the subcategory
- Capacitors
- EMI Filters
- Supercapacitors
- Power surge protection
- Go to the subcategory
-
Relays and Contactors
- Relays and Contactors - Theory
- 3-Phase AC Semiconductor Relays
- DC Semiconductor Relays
- Controllers, Control Systems and Accessories
- Soft Starters and Reversible Relays
- Electromechanical Relays
- Contactors
- Rotary Switches
-
Single-Phase AC Semiconductor Relays
- AC ONE PHASE RELAYS 1 series| D2425 | D2450
- One phase semiconductor AC relays CWA and CWD series
- One phase semiconductor AC relays CMRA and CMRD series
- One phase semiconductor AC relays - PS series
- Double and quadruple semiconductor AC relays - D24 D, TD24 Q, H12D48 D series
- One phase semiconductor relays - gn series
- Ckr series single phase solid state relays
- One phase AC semiconductor relays for DIN bus - ERDA I ERAA series
- 150A AC single phase relays
- Rail Mountable Solid State Relays With Integrated Heat Sink - ENDA, ERDA1 / ERAA1 series
- Go to the subcategory
- Single-Phase AC Semiconductor Relays for PCBs
- Interface Relays
- Go to the subcategory
- Cores and Other Inductive Components
- Heatsinks, Varistors, Thermal Protection
- Fans
- Air Conditioning, Accessories for Electrical Cabinets, Coolers
-
Batteries, Chargers, Buffer Power Supplies and Inverters
- Batteries, Chargers - Theoretical Description
- Modular Li-ion Battery Building Blocks, Custom Batteries, BMS
- Batteries
- Battery Chargers and Accessories
- Uninterruptible Power Supply and Buffer Power Supplies
- Inverters and Photovoltaic Equipments
- Energy storage
- Fuel cells
- Lithium-ion batteries
- Go to the subcategory
-
Automatics
- Futaba Drone Parts
- Limit Switches, Microswitches
- Sensors, Transducers
-
Infrared Thermometers (Pyrometers)
- IR-TE Series - Water-proof Palm-sized Radiation Thermometer
- IR-TA Series - Handheld Type Radiation Thermometer
- IR-H Series - Handheld Type Radiation Thermometer
- IR-BA Series - High-speed Compact Radiation Thermometer
- IR-FA Series - Fiber Optic Radiation Thermometer
- IR-BZ Series - Compact Infrared Thermometers
- Go to the subcategory
- Counters, Time Relays, Panel Meters
- Industrial Protection Devices
- Light and Sound Signalling
- Thermographic Camera
- LED Displays
- Control Equipments
-
Recorders
- Hybrid Recorders - AL3000 Series | CHINO
- Graphic Recorder - KR2000 Series | CHINO
- Ubiquitous Recorders - KR5000 Series | CHINO
- Palm-sized Temperature/Humidity Meters - HN-CH Series | CHINO
- Consumables for Recorders
- 71VR1 - Compact Paperless Recorder | M-SYSTEM
- Graphic Recorder - KR3000 Series | CHINO
- PC Recorders - R1M Series | M-SYSTEM
- PC Recorders - R2M Series | M-SYSTEM
- PC Recorders - RZMS Series | M-SYSTEM
- PC Recorders - RZUS Series | M-SYSTEM
- Go to the subcategory
- Go to the subcategory
-
Cables, Litz wires, Conduits, Flexible connections
- Wires
- Litz wires
- Cables for extreme applications
- Sleevings
-
Braids
- Flat Braids
- Round Braids
- Very Flexible Flat Braids
- Very Flexible Round Braids
- Cylindrical Cooper Braids
- Cylindrical Cooper Braids and Sleevings
- Flexible Earthing Connections
- Galvanized and Stainless Steel Cylindrical Braids
- PCV Insulated Copper Braids (temp. up to 85C)
- Flat Aluminium Braids
- Junction Set - Braids and Tubes
- Go to the subcategory
- Traction Equipment
- Cable Terminals
- Flexible Insulated Busbars
- Flexible Multilayer Busbars
- Cable Duct Systems
- Hoses
- Go to the subcategory
- View all categories
-
Semiconductors
-
-
- Suppliers
-
Applications
- CNC Machine Tools
- DC and AC Drives (Inverters)
- Energetics
- Energy bank
- Equipment and Components for Hazardous Areas [Ex]
- Equipment for Distribution, Control and Telecommunications Cabinets
- HVAC Automation
- Induction Heating
- Industrial Automation
- Industrial Protective Devices
- Machines for Drying and Wood Processing
- Machines for Thermoforming Plastics
- Mining, Metallurgy and Foundry
- Motors and Transformers
- Power Supplies (UPS) and Rectifier Systems
- Printing
- Temperature Measurement and Regulation
- Test and Laboratory Measurements
- Tram and Railway Traction
- Welding Machines
-
Assembly
-
-
Montaż urządzeń
- Assembly of equipment on request
- Designing and Assembling of Busbar Cabinets, Switching Cabinets, Power Cabinets
- Power systems installation
- Components
- Machines built for order
- R&D research and development work
-
Industrial Testers
- Tester for diodes and thyristors measurement
- Thermal and motor circuit breakers testing stand
- Varistors and surge protectors testers
- Car fuses testing stand
- Tester for the power diode and thyristor reverse recovery charge Qrr measurement
- Rotor tester FD series
- Circuit breakers tester
- Tester for calibrating relays
- Video inspection tester for gas spring piston rods
- High-current thyristor switch
- Mesh ripping tester
- Go to the subcategory
- View all categories
-
-
-
Inductors
-
-
Modernizacja induktorów
- Repair of used inductors
- Modernization of inductors
-
Production of new inductors
- Inductors for crankshaft hardening
- Hardening of band saw teeth
- Inductors for heating elements before gluing
- Hardening of raceways of automotive wheel hub bearings
- Hardening of the drive transmission components
- Hardening of stepped shafts
- Heating in contraction joints
- Induction for scanning hardening
- Soft soldering
- Billet heaters
- Go to the subcategory
- Knowledge base
- View all categories
-
-
-
Induction devices
-
-
Urządzenia indukcyjne
-
Induction heating generators
-
Induction Heating Products Ambrell
- Generators power 500 W, frequency 150 - 400 kHz
- Generators power 1.2 - 2.4 kW, frequency 150 - 400 kHz
- Generators power 4.2 - 10 kW, frequency 150 - 400 kHz
- Generators power 10-15 kW, frequency 50-150 kHz
- Generators power 30-45 kW, frequency 50-150 kHz
- Generators power 65-135 kW, frequency 50-150 kHz
- Generators power 180-270 kW, frequency 50-150 kHz
- Generators power 20-35-50 kW, frequency 15-45 kHz
- Generators power 75-150 kW, frequency 15-45 kHz
- Generators power 200-500 kW, frequency 15-45 kHz
- Generators power 20-50 kW, frequency 5-15 kHz
- Go to the subcategory
- Induction heating products Denki Kogyo
-
JKZ induction heating generators
- Generators CX, frequency: 50-120kHz, power: 5-25kW
- Generators SWS, frequency: 15-30kHz, power: 25-260kW
- Molding and forging furnaces MFS, frequency: 0,5-10kHz, power: 80-500kW
- Melting metals furnaces MFS, frequency: 0,5-10kHz, power: 70-200kW
- Generators UHT, frequency: 200-400kHz, power: 10-160kW
- Go to the subcategory
- Lamp generators for induction heating
- Induction Heating Products - Himmelwerk
- Go to the subcategory
-
Induction Heating Products Ambrell
- Repairs and modernization
- Peripherals
-
Applications
- Medical Applications with Precision Induction Heating
- Applications for automotive industry
- Soldering
- Brazing
- Aluminum Brazing
- Brazing a magnetic steel cutting tool
- Pin Sealing
- Atmospheric Brazing
- Soldering brass and steel radiator caps
- Carbide Tipping
- Soldering a copper lug and a wire
- Go to the subcategory
- Knowledge base
- View all categories
-
Induction heating generators
-
-
-
Service
-
-
asd
- Service of industrial water coolers and air conditioners
- Machines Repairs and Modernizations
- Repair and Maintenance of Power Electronics, Electronic and Industrial Automation Devices
- HV Power Supplies for Electrostatic Precipitators
- Industrial Printers and Labelling Machines
- Certificates / Entitlements
- View all categories
-
-
- Contact
- Zobacz wszystkie kategorie
Basics of Electromagnetic Compatibility: What Is It and Why Is It Important? 2 of 8

Basics of Electromagnetic Compatibility: What Is It and Why Is It Important? 2 of 8
Explanation of Electromagnetic Interference
Electromagnetic interference refers to unwanted electromagnetic signals that can affect the operation of electronic devices and systems. They come in various forms such as radio waves, electromagnetic pulses, electrical surges, or conducted disturbances.
Electromagnetic interference can have a negative impact on devices, causing errors in data transmission, loss of information, operational instability, or even complete system failure. Examples of electromagnetic interference include:
Radiated emissions: These are unwanted electromagnetic signals emitted by devices that can interfere with the operation of other devices. They can originate from electronic devices as well as external sources such as radio transmissions, television broadcasts, telecommunications, or radars.
Surges and conducted disturbances: These are sudden changes in voltage or current in the electrical network that can cause electromagnetic disturbances. They can be caused by storms, short circuits, switching of electrical devices, or improper electrical connections.
Conducted interference: These are electromagnetic disturbances that are transmitted through electrical cables and can affect the operation of other devices. They can occur, for example, due to improper cable shielding, improper wire design, or the presence of strong magnetic fields in the environment.
Understanding and explaining electromagnetic interference is important for ensuring Electromagnetic Compatibility (EMC). EMC practices involve the application of appropriate design techniques, shielding, filtering, attenuation, and cable management to minimize the impact of electromagnetic interference on the operation of devices and systems.
It is important for manufacturers and designers to consider electromagnetic interference in the early stages of the design process to avoid EMC issues. Conducting proper EMC tests and adhering to standards and regulations related to Electromagnetic Compatibility helps ensure that devices will operate correctly and will not interfere with other devices in their environment.
Examples of Sources of Electromagnetic Interference
In today's electrified and electronic world, there are many different sources of electromagnetic interference that can affect the operation of electronic devices. Here are a few examples of common sources of electromagnetic interference:
- Electronic devices
Various electronic devices such as televisions, computers, cell phones, wireless routers, or speakers can generate electromagnetic interference in the form of radiated emissions. Signals emitted by one device can interfere with the operation of other nearby devices, especially if they operate in the same frequency. - Medical equipment
Many medical devices such as magnetic resonance imaging (MRI) machines, computerized tomography (CT) scanners, electrocardiographs (ECGs), or defibrillators generate strong electromagnetic fields for diagnosing and treating patients. These fields can interfere with the operation of other electronic devices in their vicinity, so appropriate protective measures are taken in hospitals and medical facilities. - Electrical and electromechanical devices
Electric motors, transformers, compressors, fluorescent ballasts, and other electromechanical devices generate electromagnetic fields during their operation. These fields can cause electromagnetic interference in other devices located in their close proximity. - Telecommunication networks
Radio transmissions, cellular networks, satellite television, and other telecommunication systems generate electromagnetic signals that can interfere with the operation of other devices nearby. In case of improper antenna design, installation, or shielding, interference can propagate over a greater distance. - External environment
External factors such as lightning strikes, solar radiation, strong magnetic fields near transformer substations, or other sources of interference in the natural environment can affect the operation of electronic devices.
These examples show that electromagnetic interference can originate from both internal and external sources. That is why it is important to design, test, and implement appropriate protective measures and EMC principles to minimize the impact of these interferences on the operation of electronic devices.
Potential Effects of Electromagnetic Interference on Electronic Devices
Electromagnetic interference can have a range of potential effects on the operation of electronic devices. Inadequate management of interference can lead to various problems that can affect the reliability, performance, and safety of the devices. Here are a few potential effects of electromagnetic interference on electronic devices:
- Failures and damages
Strong electromagnetic interference can cause failures and damages to electronic components. For example, sudden electrical surges or electromagnetic pulses can contribute to component burnout, damage microprocessors, memory, or other critical components. - Data transmission errors
Electromagnetic interference can disrupt data transmission in communication networks. It can cause errors in information transfer, signal distortions, or even data loss. In the case of communication systems, faulty transmission can lead to disruptions in connections, deteriorated call quality, or loss of transmitted data. - Instability and operational errors
Electromagnetic interference can cause instability in the operation of electronic devices. It can result in interrupted connections, unexpected program freezes, malfunctioning sensors, or controllers. In extreme cases, it can lead to complete device failure. - Electromagnetic interference
Electromagnetic interference can cause mutual interference between different devices. If devices are not adequately resistant to interference or properly isolated, mutual interference can occur, leading to deteriorated performance and increased chances of failure. - Threat to safety
In some cases, electromagnetic interference can pose a safety hazard. For example, in the case of medical systems such as implants, interference can affect the proper functioning of these devices, which can have serious consequences for the patient.
That is why managing Electromagnetic Compatibility (EMC) is extremely important. Through proper design, testing, and adherence to EMC standards and regulations, potential effects of electromagnetic interference can be minimized, ensuring reliable operation of electronic devices.
Related product
Related posts


Leave a comment