BackX
-
Components
-
-
Category
-
Semiconductors
- Diodes
- Thyristors
-
Electro-insulated Modules
- Electro-insulated Modules | VISHAY (IR)
- Electro-insulated Modules | INFINEON (EUPEC)
- Electro-insulated Modules | Semikron
- Electro-insulated Modules | POWEREX
- Electro-insulated Modules | IXYS
- Electro-insulated Modules | POSEICO
- Electro-insulated Modules | ABB
- Electro-insulated Modules | TECHSEM
- Go to the subcategory
- Bridge Rectifiers
-
Transistors
- Transistors | GeneSiC
- SiC MOSFET Modules | Mitsubishi
- SiC MOSFET Modules | STARPOWER
- Module SiC MOSFET ABB’s
- IGBT Modules | MITSUBISHI
- Transistor Modules | MITSUBISHI
- MOSFET Modules | MITSUBISHI
- Transistor Modules | ABB
- IGBT Modules | POWEREX
- IGBT Modules | INFINEON (EUPEC)
- Silicon Carbide (SiC) semiconductor elements
- Go to the subcategory
- Gate Drivers
- Power Blocks
- Go to the subcategory
-
Electrical Transducers
-
Current Transducers | LEM
- Closed-Loop Current Transducers (C/L)
- Open-Loop Current Transducers (O/L)
- Current Transducers supplied with unipolar voltage
- 'Eta' Current Transducers
- Current Transducers - LF xx10 Series
- Current Transducers - LH Series
- Current Transducer - HOYL and HOYS Series
- Current Transducers - GO–SME & GO–SMS Series
- AUTOMOTIVE current transducers
- Go to the subcategory
-
Voltage Transducers | LEM
- Voltage Transducers - LV Series
- Voltage Transducers - DVL Series
- Precision Voltage Transducers with double magnetic core - CV Series
- Voltage Transducer for Traction - DV 4200/SP4
- Voltage Transducers - DVM Series
- Voltage Transducer - DVC 1000-P
- Voltage Transducers - DVC 1000 Series
- Go to the subcategory
- Precision Current Transducers | LEM
- Go to the subcategory
-
Current Transducers | LEM
-
Passive components (capacitors, resistors, fuses, filters)
- Resistors
-
Fuses
- Miniature Fuses for electronic circuits - ABC & AGC Series
- Tubular Fast-acting Fuses
- Time-delay Fuse Links with GL/GG & AM characteristics
- Ultrafast Fuse Links
- Fast-acting Fuses (British & American standard)
- Fast-acting Fuses (European standard)
- Traction Fuses
- High-voltage Fuse Links
- Go to the subcategory
- Capacitors
- EMI Filters
- Supercapacitors
- Power surge protection
- Go to the subcategory
-
Relays and Contactors
- Relays and Contactors - Theory
- 3-Phase AC Semiconductor Relays
- DC Semiconductor Relays
- Controllers, Control Systems and Accessories
- Soft Starters and Reversible Relays
- Electromechanical Relays
- Contactors
- Rotary Switches
-
Single-Phase AC Semiconductor Relays
- AC ONE PHASE RELAYS 1 series| D2425 | D2450
- One phase semiconductor AC relays CWA and CWD series
- One phase semiconductor AC relays CMRA and CMRD series
- One phase semiconductor AC relays - PS series
- Double and quadruple semiconductor AC relays - D24 D, TD24 Q, H12D48 D series
- One phase semiconductor relays - gn series
- Ckr series single phase solid state relays
- One phase AC semiconductor relays for DIN bus - ERDA I ERAA series
- 150A AC single phase relays
- Rail Mountable Solid State Relays With Integrated Heat Sink - ENDA, ERDA1 / ERAA1 series
- Go to the subcategory
- Single-Phase AC Semiconductor Relays for PCBs
- Interface Relays
- Go to the subcategory
- Cores and Other Inductive Components
- Heatsinks, Varistors, Thermal Protection
- Fans
- Air Conditioning, Accessories for Electrical Cabinets, Coolers
-
Batteries, Chargers, Buffer Power Supplies and Inverters
- Batteries, Chargers - Theoretical Description
- Modular Li-ion Battery Building Blocks, Custom Batteries, BMS
- Batteries
- Battery Chargers and Accessories
- Uninterruptible Power Supply and Buffer Power Supplies
- Inverters and Photovoltaic Equipments
- Energy storage
- Fuel cells
- Lithium-ion batteries
- Go to the subcategory
-
Automatics
- Futaba Drone Parts
- Limit Switches, Microswitches
- Sensors, Transducers
-
Infrared Thermometers (Pyrometers)
- IR-TE Series - Water-proof Palm-sized Radiation Thermometer
- IR-TA Series - Handheld Type Radiation Thermometer
- IR-H Series - Handheld Type Radiation Thermometer
- IR-BA Series - High-speed Compact Radiation Thermometer
- IR-FA Series - Fiber Optic Radiation Thermometer
- IR-BZ Series - Compact Infrared Thermometers
- Go to the subcategory
- Counters, Time Relays, Panel Meters
- Industrial Protection Devices
- Light and Sound Signalling
- Thermographic Camera
- LED Displays
- Control Equipments
-
Recorders
- Hybrid Recorders - AL3000 Series | CHINO
- Graphic Recorder - KR2000 Series | CHINO
- Ubiquitous Recorders - KR5000 Series | CHINO
- Palm-sized Temperature/Humidity Meters - HN-CH Series | CHINO
- Consumables for Recorders
- 71VR1 - Compact Paperless Recorder | M-SYSTEM
- Graphic Recorder - KR3000 Series | CHINO
- PC Recorders - R1M Series | M-SYSTEM
- PC Recorders - R2M Series | M-SYSTEM
- PC Recorders - RZMS Series | M-SYSTEM
- PC Recorders - RZUS Series | M-SYSTEM
- Go to the subcategory
- Go to the subcategory
-
Cables, Litz wires, Conduits, Flexible connections
- Wires
- Litz wires
- Cables for extreme applications
- Sleevings
-
Braids
- Flat Braids
- Round Braids
- Very Flexible Flat Braids
- Very Flexible Round Braids
- Cylindrical Cooper Braids
- Cylindrical Cooper Braids and Sleevings
- Flexible Earthing Connections
- Galvanized and Stainless Steel Cylindrical Braids
- PCV Insulated Copper Braids (temp. up to 85C)
- Flat Aluminium Braids
- Junction Set - Braids and Tubes
- Go to the subcategory
- Traction Equipment
- Cable Terminals
- Flexible Insulated Busbars
- Flexible Multilayer Busbars
- Cable Duct Systems
- Hoses
- Go to the subcategory
- View all categories
-
Semiconductors
-
-
- Suppliers
-
Applications
- CNC Machine Tools
- DC and AC Drives (Inverters)
- Energetics
- Energy bank
- Equipment and Components for Hazardous Areas [Ex]
- Equipment for Distribution, Control and Telecommunications Cabinets
- HVAC Automation
- Induction Heating
- Industrial Automation
- Industrial Protective Devices
- Machines for Drying and Wood Processing
- Machines for Thermoforming Plastics
- Mining, Metallurgy and Foundry
- Motors and Transformers
- Power Supplies (UPS) and Rectifier Systems
- Printing
- Temperature Measurement and Regulation
- Test and Laboratory Measurements
- Tram and Railway Traction
- Welding Machines
-
Assembly
-
-
Montaż urządzeń
- Assembly of equipment on request
- Designing and Assembling of Busbar Cabinets, Switching Cabinets, Power Cabinets
- Power systems installation
- Components
- Machines built for order
- R&D research and development work
-
Industrial Testers
- Tester for diodes and thyristors measurement
- Thermal and motor circuit breakers testing stand
- Varistors and surge protectors testers
- Car fuses testing stand
- Tester for the power diode and thyristor reverse recovery charge Qrr measurement
- Rotor tester FD series
- Circuit breakers tester
- Tester for calibrating relays
- Video inspection tester for gas spring piston rods
- High-current thyristor switch
- Mesh ripping tester
- Go to the subcategory
- View all categories
-
-
-
Inductors
-
-
Modernizacja induktorów
- Repair of used inductors
- Modernization of inductors
-
Production of new inductors
- Inductors for crankshaft hardening
- Hardening of band saw teeth
- Inductors for heating elements before gluing
- Hardening of raceways of automotive wheel hub bearings
- Hardening of the drive transmission components
- Hardening of stepped shafts
- Heating in contraction joints
- Induction for scanning hardening
- Soft soldering
- Billet heaters
- Go to the subcategory
- Knowledge base
- View all categories
-
-
-
Induction devices
-
-
Urządzenia indukcyjne
-
Induction heating generators
-
Induction Heating Products Ambrell
- Generators power 500 W, frequency 150 - 400 kHz
- Generators power 1.2 - 2.4 kW, frequency 150 - 400 kHz
- Generators power 4.2 - 10 kW, frequency 150 - 400 kHz
- Generators power 10-15 kW, frequency 50-150 kHz
- Generators power 30-45 kW, frequency 50-150 kHz
- Generators power 65-135 kW, frequency 50-150 kHz
- Generators power 180-270 kW, frequency 50-150 kHz
- Generators power 20-35-50 kW, frequency 15-45 kHz
- Generators power 75-150 kW, frequency 15-45 kHz
- Generators power 200-500 kW, frequency 15-45 kHz
- Generators power 20-50 kW, frequency 5-15 kHz
- Go to the subcategory
- Induction heating products Denki Kogyo
-
JKZ induction heating generators
- Generators CX, frequency: 50-120kHz, power: 5-25kW
- Generators SWS, frequency: 15-30kHz, power: 25-260kW
- Molding and forging furnaces MFS, frequency: 0,5-10kHz, power: 80-500kW
- Melting metals furnaces MFS, frequency: 0,5-10kHz, power: 70-200kW
- Generators UHT, frequency: 200-400kHz, power: 10-160kW
- Go to the subcategory
- Lamp generators for induction heating
- Induction Heating Products - Himmelwerk
- Go to the subcategory
-
Induction Heating Products Ambrell
- Repairs and modernization
- Peripherals
-
Applications
- Medical Applications with Precision Induction Heating
- Applications for automotive industry
- Soldering
- Brazing
- Aluminum Brazing
- Brazing a magnetic steel cutting tool
- Pin Sealing
- Atmospheric Brazing
- Soldering brass and steel radiator caps
- Carbide Tipping
- Soldering a copper lug and a wire
- Go to the subcategory
- Knowledge base
- View all categories
-
Induction heating generators
-
-
-
Service
-
-
asd
- Service of industrial water coolers and air conditioners
- Machines Repairs and Modernizations
- Repair and Maintenance of Power Electronics, Electronic and Industrial Automation Devices
- HV Power Supplies for Electrostatic Precipitators
- Industrial Printers and Labelling Machines
- Certificates / Entitlements
- View all categories
-
-
- Contact
- Zobacz wszystkie kategorie
Wybuch i strefa zagrożona wybuchem.
Wybuch powstaje, gdy mieszania substancji niebezpiecznych z powietrzem, w warunkach atmosferycznych w postaci gazów, par, mgły lub pyłu, w której po wystąpieniu zapłonu spalanie rozprzestrzenia się na całą niespaloną mieszaninę.
Wybuch i atmosfera wybuchowa
Wybuch lub eksplozja za słownikiem PWN to zjawisko gwałtownej zmiany stanu układu, w trakcie której następuje uwolnienie zgromadzonej w układzie energii potencjalnej i jej zmiana na pracę mechaniczną. Podczas wybuchu następuje gwałtowna reakcja lub rozkład wywołujący wzrost temperatury i/lub ciśnienia. Pożary nie wywołują wzrostu ciśnienia, a proces ich spalania jest raczej wolny, o tyle wybuch jest procesem, w którym spalanie jest gwałtowne i połączone z bardzo szybkim, milisekundowym wzrostem ciśnienia.
Wybuch powstaje, gdy mieszania substancji niebezpiecznych z powietrzem, w warunkach atmosferycznych w postaci gazów, par, mgły lub pyłu, w której po wystąpieniu zapłonu spalanie rozprzestrzenia się na całą niespaloną mieszaninę.
Aby wystąpił wybuch nie wystarczą tylko substancje palne i powietrze. W jednym czasie musi wystąpić więcej czynników, które przedstawiane są w formie pięciokąta wybuchowości. Pięciokąt składa się z: utleniacza; paliwa; zapłonu; wymieszania; zamknięcia. Oznacza to, że wybuch nastąpi jeśli jednocześnie w przestrzeni, która jest zamknięta znajdzie się rozdrobniony pył palny z czynnikiem utleniającym (na przykład tlenem). W takiej sytuacji musi wystąpić odpowiednie stężenie oraz źródło zapłony o odpowiednio wysokiej energii (na przykład iskra). Jeśli zabraknie jednego z czynników – wybuch nie powstanie.
Czynniki warunkujące wybuch mają różną charakterystykę.
Wybuchy mogą spowodować utratę życia i poważne obrażenia, a także znaczne szkody. Zapobieganie uwalnianiu substancji niebezpiecznych, które mogą tworzyć atmosferę wybuchową, oraz zapobieganie źródłom zapłonu to dwa szeroko stosowane sposoby ograniczania ryzyka. Użycie odpowiedniego sprzętu może w tym bardzo pomóc. Przepisy dotyczące substancji niebezpiecznych i atmosfer wybuchowych z 2002 r. (DSEAR- Dangerous Substances and Explosive Atmospheres Regulations) nakładają na pracodawców obowiązek eliminowania lub kontrolowania zagrożeń związanych z atmosferą wybuchową w miejscu pracy.W DSEAR (Dangerous Substances and Explosive Atmospheres Regulations) atmosfera wybuchowa jest definiowana jako mieszanina substancji niebezpiecznych z powietrzem, w warunkach atmosferycznych, w postaci gazów, par, mgły lub pyłu, w której po wystąpieniu zapłonu spalanie rozprzestrzenia się na całą niespaloną mieszaninę. Warunki atmosferyczne są powszechnie określane jako temperatury i ciśnienia otoczenia. To znaczy temperatury od –20°C do 40°C i ciśnienia od 0,8 do 1,1 bara.
Atmosfera wybuchowa i miejsce jej występowania
Wiele miejsc pracy może zawierać lub prowadzić działalność, która wytwarza atmosferę wybuchową lub potencjalnie wybuchową. Przykładami są miejsca, w których podczas pracy powstają lub uwalniają się łatwopalne gazy lub opary, takie jak natryskiwanie lakieru samochodowego lub miejsca pracy z drobnymi pyłami organicznymi, takimi jak mąka zbożowa lub drewno.
Strefy Wybuchowej - Definicja
Obszar niebezpieczny to trójwymiarowa przestrzeń, w której występuje lub może występować atmosfera wybuchowa. Urządzenia elektryczne w obszarze niebezpiecznym muszą być odpowiednio sklasyfikowane i skutecznie uziemione, aby zapewnić odpowiednią kontrolę wszelkiego ryzyka zapłonu. Szczególne środki ostrożności są wymagane przy budowie, instalacji i stosowaniu potencjalnych źródeł zapłonu, ponieważ pożar i wybuch mogą mieć katastrofalne skutki dla ludzi i mienia. Pierwszym krokiem do zidentyfikowania ryzyka pożaru i wybuchu instalacji jest przeprowadzenie klasyfikacji obszaru niebezpiecznego w celu określenia, czy jakiekolwiek strefy, w których istnieje lub można się spodziewać, że wystąpi atmosfera wybuchowa, będą miały wpływ na poziom ochrony sprzętu elektrycznego.
Wszędzie tam, gdzie palne ciecze, opary, gazy i palne pyły są używane, przechowywane, obsługiwane lub wytwarzane, wymagana jest klasyfikacja obszarów niebezpiecznych w celu oceny ryzyka pożaru i wybuchu. Każda osoba zarządzająca lub kontrolująca instalację z zagrożeniem atmosfery wybuchowej ma obowiązek zapewnienia takiej klasyfikacji.
ATEX - Definicja
ATEX to nazwa powszechnie nadawana dwóm europejskim dyrektywom dotyczącym kontroli atmosfer wybuchowych:
1) Dyrektywa 99/92/WE (znana również jako „ATEX 137” lub „Dyrektywa ATEX dotycząca miejsc pracy”) w sprawie minimalnych wymagań dotyczących poprawy ochrony zdrowia i bezpieczeństwa pracowników potencjalnie zagrożonych atmosferą wybuchową. Tekst dyrektywy i towarzyszące wytyczne opracowane przez UE są dostępne na stronie internetowej UE. Więcej informacji na temat tego, w jaki sposób wymagania Dyrektywy zostały wprowadzone w życie w Wielkiej Brytanii, można znaleźć w poniższej sekcji Atmosfery wybuchowe w miejscu pracy.
2) Dyrektywa 94/9/WE (znana również jako „ATEX 95” lub „Dyrektywa ATEX dotycząca urządzeń”) w sprawie zbliżenia ustawodawstw Państw Członkowskich dotyczących urządzeń i systemów ochronnych przeznaczonych do użytku w przestrzeniach zagrożonych wybuchem. Tekst dyrektywy i wytyczne pomocnicze opracowane przez UE są dostępne na stronie internetowej UE. Więcej informacji o tym, jak wymagania Dyrektywy zostały wprowadzone w życie w Wielkiej Brytanii, można znaleźć w rozdziale Urządzenia i systemy ochronne przeznaczone do użytku w atmosferach wybuchowych.
Leave a comment