-
BackX
-
Components
-
-
Category
-
Semiconductors
- Diodes
- Thyristors
-
Electro-insulated Modules
- Electro-insulated Modules | VISHAY (IR)
- Electro-insulated Modules | INFINEON (EUPEC)
- Electro-insulated Modules | Semikron
- Electro-insulated Modules | POWEREX
- Electro-insulated Modules | IXYS
- Electro-insulated Modules | POSEICO
- Electro-insulated Modules | ABB
- Electro-insulated Modules | TECHSEM
- Go to the subcategory
- Bridge Rectifiers
-
Transistors
- Transistors | GeneSiC
- SiC MOSFET Modules | Mitsubishi
- SiC MOSFET Modules | STARPOWER
- Module SiC MOSFET ABB’s
- IGBT Modules | MITSUBISHI
- Transistor Modules | MITSUBISHI
- MOSFET Modules | MITSUBISHI
- Transistor Modules | ABB
- IGBT Modules | POWEREX
- IGBT Modules | INFINEON (EUPEC)
- Silicon Carbide (SiC) semiconductor elements
- Go to the subcategory
- Gate Drivers
- Power Blocks
- Go to the subcategory
-
Electrical Transducers
-
Current Transducers | LEM
- Closed-Loop Current Transducers (C/L)
- Open-Loop Current Transducers (O/L)
- Current Transducers supplied with unipolar voltage
- 'Eta' Current Transducers
- Current Transducers - LF xx10 Series
- Current Transducers - LH Series
- Current Transducer - HOYL and HOYS Series
- Current Transducers - GO–SME & GO–SMS Series
- AUTOMOTIVE current transducers
- Go to the subcategory
-
Voltage Transducers | LEM
- Voltage Transducers - LV Series
- Voltage Transducers - DVL Series
- Precision Voltage Transducers with double magnetic core - CV Series
- Voltage Transducer for Traction - DV 4200/SP4
- Voltage Transducers - DVM Series
- Voltage Transducer - DVC 1000-P
- Voltage Transducers - DVC 1000 Series
- Go to the subcategory
- Precision Current Transducers | LEM
- Go to the subcategory
-
Current Transducers | LEM
-
Passive components (capacitors, resistors, fuses, filters)
- Resistors
-
Fuses
- Miniature Fuses for electronic circuits - ABC & AGC Series
- Tubular Fast-acting Fuses
- Time-delay Fuse Links with GL/GG & AM characteristics
- Ultrafast Fuse Links
- Fast-acting Fuses (British & American standard)
- Fast-acting Fuses (European standard)
- Traction Fuses
- High-voltage Fuse Links
- Go to the subcategory
- Capacitors
- EMI Filters
- Supercapacitors
- Power surge protection
- Go to the subcategory
-
Relays and Contactors
- Relays and Contactors - Theory
- 3-Phase AC Semiconductor Relays
- DC Semiconductor Relays
- Controllers, Control Systems and Accessories
- Soft Starters and Reversible Relays
- Electromechanical Relays
- Contactors
- Rotary Switches
-
Single-Phase AC Semiconductor Relays
- AC ONE PHASE RELAYS 1 series| D2425 | D2450
- One phase semiconductor AC relays CWA and CWD series
- One phase semiconductor AC relays CMRA and CMRD series
- One phase semiconductor AC relays - PS series
- Double and quadruple semiconductor AC relays - D24 D, TD24 Q, H12D48 D series
- One phase semiconductor relays - gn series
- Ckr series single phase solid state relays
- One phase AC semiconductor relays for DIN bus - ERDA I ERAA series
- 150A AC single phase relays
- Rail Mountable Solid State Relays With Integrated Heat Sink - ENDA, ERDA1 / ERAA1 series
- Go to the subcategory
- Single-Phase AC Semiconductor Relays for PCBs
- Interface Relays
- Go to the subcategory
- Cores and Other Inductive Components
- Heatsinks, Varistors, Thermal Protection
- Fans
- Air Conditioning, Accessories for Electrical Cabinets, Coolers
-
Batteries, Chargers, Buffer Power Supplies and Inverters
- Batteries, Chargers - Theoretical Description
- Modular Li-ion Battery Building Blocks, Custom Batteries, BMS
- Batteries
- Battery Chargers and Accessories
- Uninterruptible Power Supply and Buffer Power Supplies
- Inverters and Photovoltaic Equipments
- Energy storage
- Fuel cells
- Lithium-ion batteries
- Go to the subcategory
-
Automatics
- Futaba Drone Parts
- Limit Switches, Microswitches
- Sensors, Transducers
-
Infrared Thermometers (Pyrometers)
- IR-TE Series - Water-proof Palm-sized Radiation Thermometer
- IR-TA Series - Handheld Type Radiation Thermometer
- IR-H Series - Handheld Type Radiation Thermometer
- IR-BA Series - High-speed Compact Radiation Thermometer
- IR-FA Series - Fiber Optic Radiation Thermometer
- IR-BZ Series - Compact Infrared Thermometers
- Go to the subcategory
- Counters, Time Relays, Panel Meters
- Industrial Protection Devices
- Light and Sound Signalling
- Thermographic Camera
- LED Displays
- Control Equipments
-
Recorders
- Hybrid Recorders - AL3000 Series | CHINO
- Graphic Recorder - KR2000 Series | CHINO
- Ubiquitous Recorders - KR5000 Series | CHINO
- Palm-sized Temperature/Humidity Meters - HN-CH Series | CHINO
- Consumables for Recorders
- 71VR1 - Compact Paperless Recorder | M-SYSTEM
- Graphic Recorder - KR3000 Series | CHINO
- PC Recorders - R1M Series | M-SYSTEM
- PC Recorders - R2M Series | M-SYSTEM
- PC Recorders - RZMS Series | M-SYSTEM
- PC Recorders - RZUS Series | M-SYSTEM
- Go to the subcategory
- Go to the subcategory
-
Cables, Litz wires, Conduits, Flexible connections
- Wires
- Litz wires
- Cables for extreme applications
- Sleevings
-
Braids
- Flat Braids
- Round Braids
- Very Flexible Flat Braids
- Very Flexible Round Braids
- Cylindrical Cooper Braids
- Cylindrical Cooper Braids and Sleevings
- Flexible Earthing Connections
- Galvanized and Stainless Steel Cylindrical Braids
- PCV Insulated Copper Braids (temp. up to 85C)
- Flat Aluminium Braids
- Junction Set - Braids and Tubes
- Go to the subcategory
- Traction Equipment
- Cable Terminals
- Flexible Insulated Busbars
- Flexible Multilayer Busbars
- Cable Duct Systems
- Hoses
- Go to the subcategory
- View all categories
-
Semiconductors
-
-
- Suppliers
-
Applications
- CNC Machine Tools
- DC and AC Drives (Inverters)
- Energetics
- Energy bank
- Equipment and Components for Hazardous Areas [Ex]
- Equipment for Distribution, Control and Telecommunications Cabinets
- HVAC Automation
- Induction Heating
- Industrial Automation
- Industrial Protective Devices
- Machines for Drying and Wood Processing
- Machines for Thermoforming Plastics
- Mining, Metallurgy and Foundry
- Motors and Transformers
- Power Supplies (UPS) and Rectifier Systems
- Printing
- Temperature Measurement and Regulation
- Test and Laboratory Measurements
- Tram and Railway Traction
- Welding Machines
-
Assembly
-
-
Montaż urządzeń
- Assembly of equipment on request
- Designing and Assembling of Busbar Cabinets, Switching Cabinets, Power Cabinets
- Power systems installation
- Components
- Machines built for order
- R&D research and development work
-
Industrial Testers
- Tester for diodes and thyristors measurement
- Thermal and motor circuit breakers testing stand
- Varistors and surge protectors testers
- Car fuses testing stand
- Tester for the power diode and thyristor reverse recovery charge Qrr measurement
- Rotor tester FD series
- Circuit breakers tester
- Tester for calibrating relays
- Video inspection tester for gas spring piston rods
- High-current thyristor switch
- Mesh ripping tester
- Go to the subcategory
- View all categories
-
-
-
Inductors
-
-
Modernizacja induktorów
- Repair of used inductors
- Modernization of inductors
-
Production of new inductors
- Inductors for crankshaft hardening
- Hardening of band saw teeth
- Inductors for heating elements before gluing
- Hardening of raceways of automotive wheel hub bearings
- Hardening of the drive transmission components
- Hardening of stepped shafts
- Heating in contraction joints
- Induction for scanning hardening
- Soft soldering
- Billet heaters
- Go to the subcategory
- Knowledge base
- View all categories
-
-
-
Induction devices
-
-
Urządzenia indukcyjne
-
Induction heating generators
-
Induction Heating Products Ambrell
- Generators power 500 W, frequency 150 - 400 kHz
- Generators power 1.2 - 2.4 kW, frequency 150 - 400 kHz
- Generators power 4.2 - 10 kW, frequency 150 - 400 kHz
- Generators power 10-15 kW, frequency 50-150 kHz
- Generators power 30-45 kW, frequency 50-150 kHz
- Generators power 65-135 kW, frequency 50-150 kHz
- Generators power 180-270 kW, frequency 50-150 kHz
- Generators power 20-35-50 kW, frequency 15-45 kHz
- Generators power 75-150 kW, frequency 15-45 kHz
- Generators power 200-500 kW, frequency 15-45 kHz
- Generators power 20-50 kW, frequency 5-15 kHz
- Go to the subcategory
- Induction heating products Denki Kogyo
-
JKZ induction heating generators
- Generators CX, frequency: 50-120kHz, power: 5-25kW
- Generators SWS, frequency: 15-30kHz, power: 25-260kW
- Molding and forging furnaces MFS, frequency: 0,5-10kHz, power: 80-500kW
- Melting metals furnaces MFS, frequency: 0,5-10kHz, power: 70-200kW
- Generators UHT, frequency: 200-400kHz, power: 10-160kW
- Go to the subcategory
- Lamp generators for induction heating
- Induction Heating Products - Himmelwerk
- Go to the subcategory
-
Induction Heating Products Ambrell
- Repairs and modernization
- Peripherals
-
Applications
- Medical Applications with Precision Induction Heating
- Applications for automotive industry
- Soldering
- Brazing
- Aluminum Brazing
- Brazing a magnetic steel cutting tool
- Pin Sealing
- Atmospheric Brazing
- Soldering brass and steel radiator caps
- Carbide Tipping
- Soldering a copper lug and a wire
- Go to the subcategory
- Knowledge base
- View all categories
-
Induction heating generators
-
-
-
Service
-
-
asd
- Service of industrial water coolers and air conditioners
- Machines Repairs and Modernizations
- Repair and Maintenance of Power Electronics, Electronic and Industrial Automation Devices
- HV Power Supplies for Electrostatic Precipitators
- Industrial Printers and Labelling Machines
- Certificates / Entitlements
- View all categories
-
-
- Contact
- Zobacz wszystkie kategorie
Photos are for informational purposes only. View product specification
please use latin characters
Perfect chargers for any type of battery
Charge voltage can be precisely adjusted to suit any sealed or unsealed battery system.
In particular, sealed maintenance free batteries must be charged correctly in order to ensure a long service life.
Overvoltage will result in excessive gassing and venting of a sealed battery. The battery will dry out and fail.
Suitable for AC and DC supply (AC-DC and DC-DC operation)
Except for the 3 phase input models, the chargers alsoaccept a DC supply.
Controlled charging
Every TG charger has a microprocessor, which accurately controls the charging in three steps. The charging
process takes place in accordance with the IUoUo characteristic and charges more rapidly than other processes.
Use of TG chargers as a power supply
As a result of the perfectly stabilized output voltage, a TG charger can be used as a power supply if batteries or
large buffer capacitors are not available.
Two outputs to charge 2 battery banks (24V models only)
The TG chargers feature 2 isolated outputs. The second output, limited to approximately 4 A and with a slightly
lower output voltage, is intended to top up a starter battery.
To increase battery life: temperature compensation
Every Skylla TG charger comes with a battery temperature sensor. When connected, charge voltage will
automatically decrease with increasing battery temperature. This feature is especially recommended for sealed
batteries which otherwise might be overcharged and dry out due to venting.
Battery voltage sense
In order to compensate for voltage loss due to cable resistance, TG chargers are provided with a voltage sense
facility so that the battery always receives the correct charge voltage
Learn more about batteries and battery charging
To learn more about batteries and charging batteries, please refer to our book ‘Energy Unlimited’ (available free
of charge from Victron Energy and downloadable from www.victronenergy.com).
Charge curve
Application example
Skylla | 24/30 TG 24/50 TG | 24/50 TG 3 phase | 24/80 TG | 24/100 TG | 24/100 TG 3 phase | 48/25 TG | 48/50 TG |
---|---|---|---|---|---|---|---|
Input voltage (V AC) | 230 | 3 x 400 | 230 | 230 | 3 x 400 | 230 | 230 |
Input voltage range (V AC) | 185-264 | 320-450 | 185-264 | 185-264 | 320-450 | 185-264 | 185-264 |
Input voltage range (V DC) | 180-400 | n. a. | 180-400 | 180-400 | n. a. | 180-400 | 180-400 |
Frequency (Hz) | 45-65 | ||||||
Power factor | 1 | ||||||
Charge voltage 'absorption' (V DC) | 28,5 | 28,5 | 28,5 | 28,5 | 28,5 | 57 | 57 |
Charge voltage 'float' (V DC) | 26,5 | 26,5 | 26,5 | 26,5 | 26,5 | 53 | 53 |
Charge current house batt. (A) (2) | 30 / 50 | 50 | 80 | 100 | 100 | 25 | 50 |
Charge current starter batt. (A) | 4 | 4 | 4 | 4 | 4 | n. a. | n. a. |
Charge characteristic | IUoUo (three step) | ||||||
Battery capacity (Ah) | 150-500 | 250-500 | 400-800 | 500-1000 | 500-1000 | 125-250 | 250-500 |
Temperature sensor | + | ||||||
Can be used as power supply | + | ||||||
Remote alarm | Potential free contacts 60V / 1A (1x NO and 1x NC) | ||||||
Forced cooling | + | ||||||
Protection (1) | a,b,c,d | ||||||
Operating temp. range | -20 to 60°C (0 - 140°F) | ||||||
Humidity (non condensing) | max 95% | ||||||
ENCLOSURE | |||||||
Material [&] Colour | aluminium (blue RAL 5012) | ||||||
Battery-connection | M8 studs | ||||||
230 V AC-connection | screw-clamp 2,5 mm² (AWG 6) | ||||||
Protection category | IP 21 | ||||||
Weight kg (lbs) | 5,5 (12.1) | 5,5 (12.1) | 5,5 (12.1) | 5,5 (12.1) | 5,5 (12.1) | 5,5 (12.1) | 5,5 (12.1) |
Dimensions hxwxd in mm (hxwxd in inches) | 365x250x147 (14.4x9.9x5.8) | 365x250x147 (14.4x9.9x5.8) | 365x250x147 (14.4x9.9x5.8) | 365x250x147 (14.4x9.9x5.8) | 365x250x147 (14.4x9.9x5.8) | 365x250x147 (14.4x9.9x5.8) | 365x250x147 (14.4x9.9x5.8) |
STANDARDS | |||||||
Safety | EN 60335-1, EN 60335-2-29 | ||||||
Emission | EN 55014-1, EN 61000-3-2 | ||||||
Immunity | EN 55014-2, EN 61000-3-3 | ||||||
1) Protection |
BMV 600S Battery Monitor The BMV 600S Battery Monitor features an advanced microprocessor control system combined with high resolution measuring systems for battery voltage and charge/discharge current. Besides this, the software includes complex calculation algorithms, like Peukert’s formula, to exactly determine the state of charge of the battery. The BMV 600S selectively displays battery voltage, current, consumed Ah or time to go. |
Skylla Control The Skylla Control allows you to alter the charge current and see the system status. Altering the charge current is useful if the shore power fuse is limited: the AC current drawn by the battery charger can be controlled by limiting the maximum output current, thereby preventing the shore power fuse from blowing. |
Charger Switch A remote on-off switch |
Battery Alarm An excessively high or low battery voltage is indicated by an audible and visual alarm. |
Send an inquiry
Are you interested in this product? Do you need additional information or individual pricing?
Contact us
Perfect chargers for any type of battery
Charge voltage can be precisely adjusted to suit any sealed or unsealed battery system.
In particular, sealed maintenance free batteries must be charged correctly in order to ensure a long service life.
Overvoltage will result in excessive gassing and venting of a sealed battery. The battery will dry out and fail.
Suitable for AC and DC supply (AC-DC and DC-DC operation)
Except for the 3 phase input models, the chargers alsoaccept a DC supply.
Controlled charging
Every TG charger has a microprocessor, which accurately controls the charging in three steps. The charging
process takes place in accordance with the IUoUo characteristic and charges more rapidly than other processes.
Use of TG chargers as a power supply
As a result of the perfectly stabilized output voltage, a TG charger can be used as a power supply if batteries or
large buffer capacitors are not available.
Two outputs to charge 2 battery banks (24V models only)
The TG chargers feature 2 isolated outputs. The second output, limited to approximately 4 A and with a slightly
lower output voltage, is intended to top up a starter battery.
To increase battery life: temperature compensation
Every Skylla TG charger comes with a battery temperature sensor. When connected, charge voltage will
automatically decrease with increasing battery temperature. This feature is especially recommended for sealed
batteries which otherwise might be overcharged and dry out due to venting.
Battery voltage sense
In order to compensate for voltage loss due to cable resistance, TG chargers are provided with a voltage sense
facility so that the battery always receives the correct charge voltage
Learn more about batteries and battery charging
To learn more about batteries and charging batteries, please refer to our book ‘Energy Unlimited’ (available free
of charge from Victron Energy and downloadable from www.victronenergy.com).
Charge curve
Application example
Skylla | 24/30 TG 24/50 TG | 24/50 TG 3 phase | 24/80 TG | 24/100 TG | 24/100 TG 3 phase | 48/25 TG | 48/50 TG |
---|---|---|---|---|---|---|---|
Input voltage (V AC) | 230 | 3 x 400 | 230 | 230 | 3 x 400 | 230 | 230 |
Input voltage range (V AC) | 185-264 | 320-450 | 185-264 | 185-264 | 320-450 | 185-264 | 185-264 |
Input voltage range (V DC) | 180-400 | n. a. | 180-400 | 180-400 | n. a. | 180-400 | 180-400 |
Frequency (Hz) | 45-65 | ||||||
Power factor | 1 | ||||||
Charge voltage 'absorption' (V DC) | 28,5 | 28,5 | 28,5 | 28,5 | 28,5 | 57 | 57 |
Charge voltage 'float' (V DC) | 26,5 | 26,5 | 26,5 | 26,5 | 26,5 | 53 | 53 |
Charge current house batt. (A) (2) | 30 / 50 | 50 | 80 | 100 | 100 | 25 | 50 |
Charge current starter batt. (A) | 4 | 4 | 4 | 4 | 4 | n. a. | n. a. |
Charge characteristic | IUoUo (three step) | ||||||
Battery capacity (Ah) | 150-500 | 250-500 | 400-800 | 500-1000 | 500-1000 | 125-250 | 250-500 |
Temperature sensor | + | ||||||
Can be used as power supply | + | ||||||
Remote alarm | Potential free contacts 60V / 1A (1x NO and 1x NC) | ||||||
Forced cooling | + | ||||||
Protection (1) | a,b,c,d | ||||||
Operating temp. range | -20 to 60°C (0 - 140°F) | ||||||
Humidity (non condensing) | max 95% | ||||||
ENCLOSURE | |||||||
Material [&] Colour | aluminium (blue RAL 5012) | ||||||
Battery-connection | M8 studs | ||||||
230 V AC-connection | screw-clamp 2,5 mm² (AWG 6) | ||||||
Protection category | IP 21 | ||||||
Weight kg (lbs) | 5,5 (12.1) | 5,5 (12.1) | 5,5 (12.1) | 5,5 (12.1) | 5,5 (12.1) | 5,5 (12.1) | 5,5 (12.1) |
Dimensions hxwxd in mm (hxwxd in inches) | 365x250x147 (14.4x9.9x5.8) | 365x250x147 (14.4x9.9x5.8) | 365x250x147 (14.4x9.9x5.8) | 365x250x147 (14.4x9.9x5.8) | 365x250x147 (14.4x9.9x5.8) | 365x250x147 (14.4x9.9x5.8) | 365x250x147 (14.4x9.9x5.8) |
STANDARDS | |||||||
Safety | EN 60335-1, EN 60335-2-29 | ||||||
Emission | EN 55014-1, EN 61000-3-2 | ||||||
Immunity | EN 55014-2, EN 61000-3-3 | ||||||
1) Protection |
BMV 600S Battery Monitor The BMV 600S Battery Monitor features an advanced microprocessor control system combined with high resolution measuring systems for battery voltage and charge/discharge current. Besides this, the software includes complex calculation algorithms, like Peukert’s formula, to exactly determine the state of charge of the battery. The BMV 600S selectively displays battery voltage, current, consumed Ah or time to go. |
Skylla Control The Skylla Control allows you to alter the charge current and see the system status. Altering the charge current is useful if the shore power fuse is limited: the AC current drawn by the battery charger can be controlled by limiting the maximum output current, thereby preventing the shore power fuse from blowing. |
Charger Switch A remote on-off switch |
Battery Alarm An excessively high or low battery voltage is indicated by an audible and visual alarm. |
Your review appreciation cannot be sent
Report comment
Report sent
Your report cannot be sent
Write your review
Review sent
Your review cannot be sent