BackX
-
Components
-
-
Category
-
Semiconductors
- Diodes
- Thyristors
-
Electro-insulated Modules
- Electro-insulated Modules | VISHAY (IR)
- Electro-insulated Modules | INFINEON (EUPEC)
- Electro-insulated Modules | Semikron
- Electro-insulated Modules | POWEREX
- Electro-insulated Modules | IXYS
- Electro-insulated Modules | POSEICO
- Electro-insulated Modules | ABB
- Electro-insulated Modules | TECHSEM
- Go to the subcategory
- Bridge Rectifiers
-
Transistors
- Transistors | GeneSiC
- SiC MOSFET Modules | Mitsubishi
- SiC MOSFET Modules | STARPOWER
- Module SiC MOSFET ABB’s
- IGBT Modules | MITSUBISHI
- Transistor Modules | MITSUBISHI
- MOSFET Modules | MITSUBISHI
- Transistor Modules | ABB
- IGBT Modules | POWEREX
- IGBT Modules | INFINEON (EUPEC)
- Silicon Carbide (SiC) semiconductor elements
- Go to the subcategory
- Gate Drivers
- Power Blocks
- Go to the subcategory
-
Electrical Transducers
-
Current Transducers | LEM
- Closed-Loop Current Transducers (C/L)
- Open-Loop Current Transducers (O/L)
- Current Transducers supplied with unipolar voltage
- 'Eta' Current Transducers
- Current Transducers - LF xx10 Series
- Current Transducers - LH Series
- Current Transducer - HOYL and HOYS Series
- Current Transducers - GO–SME & GO–SMS Series
- AUTOMOTIVE current transducers
- Go to the subcategory
-
Voltage Transducers | LEM
- Voltage Transducers - LV Series
- Voltage Transducers - DVL Series
- Precision Voltage Transducers with double magnetic core - CV Series
- Voltage Transducer for Traction - DV 4200/SP4
- Voltage Transducers - DVM Series
- Voltage Transducer - DVC 1000-P
- Voltage Transducers - DVC 1000 Series
- Go to the subcategory
- Precision Current Transducers | LEM
- Go to the subcategory
-
Current Transducers | LEM
-
Passive components (capacitors, resistors, fuses, filters)
- Resistors
-
Fuses
- Miniature Fuses for electronic circuits - ABC & AGC Series
- Tubular Fast-acting Fuses
- Time-delay Fuse Links with GL/GG & AM characteristics
- Ultrafast Fuse Links
- Fast-acting Fuses (British & American standard)
- Fast-acting Fuses (European standard)
- Traction Fuses
- High-voltage Fuse Links
- Go to the subcategory
- Capacitors
- EMI Filters
- Supercapacitors
- Power surge protection
- Go to the subcategory
-
Relays and Contactors
- Relays and Contactors - Theory
- 3-Phase AC Semiconductor Relays
- DC Semiconductor Relays
- Controllers, Control Systems and Accessories
- Soft Starters and Reversible Relays
- Electromechanical Relays
- Contactors
- Rotary Switches
-
Single-Phase AC Semiconductor Relays
- AC ONE PHASE RELAYS 1 series| D2425 | D2450
- One phase semiconductor AC relays CWA and CWD series
- One phase semiconductor AC relays CMRA and CMRD series
- One phase semiconductor AC relays - PS series
- Double and quadruple semiconductor AC relays - D24 D, TD24 Q, H12D48 D series
- One phase semiconductor relays - gn series
- Ckr series single phase solid state relays
- One phase AC semiconductor relays for DIN bus - ERDA I ERAA series
- 150A AC single phase relays
- Rail Mountable Solid State Relays With Integrated Heat Sink - ENDA, ERDA1 / ERAA1 series
- Go to the subcategory
- Single-Phase AC Semiconductor Relays for PCBs
- Interface Relays
- Go to the subcategory
- Cores and Other Inductive Components
- Heatsinks, Varistors, Thermal Protection
- Fans
- Air Conditioning, Accessories for Electrical Cabinets, Coolers
-
Batteries, Chargers, Buffer Power Supplies and Inverters
- Batteries, Chargers - Theoretical Description
- Modular Li-ion Battery Building Blocks, Custom Batteries, BMS
- Batteries
- Battery Chargers and Accessories
- Uninterruptible Power Supply and Buffer Power Supplies
- Inverters and Photovoltaic Equipments
- Energy storage
- Fuel cells
- Lithium-ion batteries
- Go to the subcategory
-
Automatics
- Futaba Drone Parts
- Limit Switches, Microswitches
- Sensors, Transducers
-
Infrared Thermometers (Pyrometers)
- IR-TE Series - Water-proof Palm-sized Radiation Thermometer
- IR-TA Series - Handheld Type Radiation Thermometer
- IR-H Series - Handheld Type Radiation Thermometer
- IR-BA Series - High-speed Compact Radiation Thermometer
- IR-FA Series - Fiber Optic Radiation Thermometer
- IR-BZ Series - Compact Infrared Thermometers
- Go to the subcategory
- Counters, Time Relays, Panel Meters
- Industrial Protection Devices
- Light and Sound Signalling
- Thermographic Camera
- LED Displays
- Control Equipments
-
Recorders
- Hybrid Recorders - AL3000 Series | CHINO
- Graphic Recorder - KR2000 Series | CHINO
- Ubiquitous Recorders - KR5000 Series | CHINO
- Palm-sized Temperature/Humidity Meters - HN-CH Series | CHINO
- Consumables for Recorders
- 71VR1 - Compact Paperless Recorder | M-SYSTEM
- Graphic Recorder - KR3000 Series | CHINO
- PC Recorders - R1M Series | M-SYSTEM
- PC Recorders - R2M Series | M-SYSTEM
- PC Recorders - RZMS Series | M-SYSTEM
- PC Recorders - RZUS Series | M-SYSTEM
- Go to the subcategory
- Go to the subcategory
-
Cables, Litz wires, Conduits, Flexible connections
- Wires
- Litz wires
- Cables for extreme applications
- Sleevings
-
Braids
- Flat Braids
- Round Braids
- Very Flexible Flat Braids
- Very Flexible Round Braids
- Cylindrical Cooper Braids
- Cylindrical Cooper Braids and Sleevings
- Flexible Earthing Connections
- Galvanized and Stainless Steel Cylindrical Braids
- PCV Insulated Copper Braids (temp. up to 85C)
- Flat Aluminium Braids
- Junction Set - Braids and Tubes
- Go to the subcategory
- Traction Equipment
- Cable Terminals
- Flexible Insulated Busbars
- Flexible Multilayer Busbars
- Cable Duct Systems
- Hoses
- Go to the subcategory
- View all categories
-
Semiconductors
-
-
- Suppliers
-
Applications
- CNC Machine Tools
- DC and AC Drives (Inverters)
- Energetics
- Energy bank
- Equipment and Components for Hazardous Areas [Ex]
- Equipment for Distribution, Control and Telecommunications Cabinets
- HVAC Automation
- Induction Heating
- Industrial Automation
- Industrial Protective Devices
- Machines for Drying and Wood Processing
- Machines for Thermoforming Plastics
- Mining, Metallurgy and Foundry
- Motors and Transformers
- Power Supplies (UPS) and Rectifier Systems
- Printing
- Temperature Measurement and Regulation
- Test and Laboratory Measurements
- Tram and Railway Traction
- Welding Machines
-
Assembly
-
-
Montaż urządzeń
- Assembly of equipment on request
- Designing and Assembling of Busbar Cabinets, Switching Cabinets, Power Cabinets
- Power systems installation
- Components
- Machines built for order
- R&D research and development work
-
Industrial Testers
- Tester for diodes and thyristors measurement
- Thermal and motor circuit breakers testing stand
- Varistors and surge protectors testers
- Car fuses testing stand
- Tester for the power diode and thyristor reverse recovery charge Qrr measurement
- Rotor tester FD series
- Circuit breakers tester
- Tester for calibrating relays
- Video inspection tester for gas spring piston rods
- High-current thyristor switch
- Mesh ripping tester
- Go to the subcategory
- View all categories
-
-
-
Inductors
-
-
Modernizacja induktorów
- Repair of used inductors
- Modernization of inductors
-
Production of new inductors
- Inductors for crankshaft hardening
- Hardening of band saw teeth
- Inductors for heating elements before gluing
- Hardening of raceways of automotive wheel hub bearings
- Hardening of the drive transmission components
- Hardening of stepped shafts
- Heating in contraction joints
- Induction for scanning hardening
- Soft soldering
- Billet heaters
- Go to the subcategory
- Knowledge base
- View all categories
-
-
-
Induction devices
-
-
Urządzenia indukcyjne
-
Induction heating generators
-
Induction Heating Products Ambrell
- Generators power 500 W, frequency 150 - 400 kHz
- Generators power 1.2 - 2.4 kW, frequency 150 - 400 kHz
- Generators power 4.2 - 10 kW, frequency 150 - 400 kHz
- Generators power 10-15 kW, frequency 50-150 kHz
- Generators power 30-45 kW, frequency 50-150 kHz
- Generators power 65-135 kW, frequency 50-150 kHz
- Generators power 180-270 kW, frequency 50-150 kHz
- Generators power 20-35-50 kW, frequency 15-45 kHz
- Generators power 75-150 kW, frequency 15-45 kHz
- Generators power 200-500 kW, frequency 15-45 kHz
- Generators power 20-50 kW, frequency 5-15 kHz
- Go to the subcategory
- Induction heating products Denki Kogyo
-
JKZ induction heating generators
- Generators CX, frequency: 50-120kHz, power: 5-25kW
- Generators SWS, frequency: 15-30kHz, power: 25-260kW
- Molding and forging furnaces MFS, frequency: 0,5-10kHz, power: 80-500kW
- Melting metals furnaces MFS, frequency: 0,5-10kHz, power: 70-200kW
- Generators UHT, frequency: 200-400kHz, power: 10-160kW
- Go to the subcategory
- Lamp generators for induction heating
- Induction Heating Products - Himmelwerk
- Go to the subcategory
-
Induction Heating Products Ambrell
- Repairs and modernization
- Peripherals
-
Applications
- Medical Applications with Precision Induction Heating
- Applications for automotive industry
- Soldering
- Brazing
- Aluminum Brazing
- Brazing a magnetic steel cutting tool
- Pin Sealing
- Atmospheric Brazing
- Soldering brass and steel radiator caps
- Carbide Tipping
- Soldering a copper lug and a wire
- Go to the subcategory
- Knowledge base
- View all categories
-
Induction heating generators
-
-
-
Service
-
-
asd
- Service of industrial water coolers and air conditioners
- Machines Repairs and Modernizations
- Repair and Maintenance of Power Electronics, Electronic and Industrial Automation Devices
- HV Power Supplies for Electrostatic Precipitators
- Industrial Printers and Labelling Machines
- Certificates / Entitlements
- View all categories
-
-
- Contact
- Zobacz wszystkie kategorie
Photos are for informational purposes only. View product specification
please use latin characters
Network Analyzer - AHM1
The AHM1 is designed to be used for the measurement and calculation of electrical variables such as voltage, current, frequency, power, power factor, energy, harmonic components, etc. Memory of 8 MB incorporated.
GENERAL FEATURES
- IN 96 x 96 mm.
- MEMORY 8 MB.
- THD on V and I.
- HARMONIC RMS (1-31).
- DIGITAL INPUT/OUTPUT.
- MAXIMUM DEMAND, A, kW, kVA, kvar.
- PROGRAMMABLE RATED V AND I.
- 4 QUADRANT MEASUREMENT.
- RS-485 PORT.
- MAXIMUM AND MINIMUM VALUES.
- ETHERNET TCP-IP (Optional).
ELECTRICAL PARAMETER | UNIT | L1 | L2 | L3 | TOTAL | MAX/MIN | DEMAND |
---|---|---|---|---|---|---|---|
Voltage (Phase - Neutral) | V, kV | | | | | ||
Voltage (Phase - Phase) | V, kV | | | | | ||
Current | A, kA | | | | | | |
Neutral current | A, kA | | |||||
Active power (P) | kW, MW, GW | | | | | | |
Reactive power (Q) | kvar, Mvar, Gvar | | | | | | |
Apparent power (S) | kVA | | | | | | |
Power factor (Cos φ) | PF | | | | | | |
Frequency | Hz | | | ||||
Import active energy (EP+) | Wh, M Wh, G Wh | | |||||
Export active energy (EP-) | kWh, M Wh, G wh | | |||||
Import reactive energy (Eq+) | kvarh, M varh ,G varh | | |||||
Export reactive energy (Eq-) | kvarh, M varh, G varh | | |||||
Hour meter | h: min | | |||||
THD Current and Voltage | A, V | | | | |||
Harmonic RMS-U and I (1-31) | % | | | | |||
Unbalanced -U and I | % | |
2 DIGITAL INPUTS
- See input state
- Select tariff (Up to 4 tariff available)
- Pulse counter
- Maximum demand synchronization
OVERLOAD
- 2 Vn x 10 s
- 1,2 Vn permanent
- 20 In x 1 s
- 2 In permanent
2 CONTACT OUTPUTS
- Alarms
- Energy pulses
- Remote mode
INPUT | |
---|---|
Rated voltage (Un) | 3 x 400 / 690 V AC |
Overload | 1,2 Un |
Impedance | 1MΩ |
Rated current (In) | 1 A and 5 A |
Overload continuous | 2 In |
Overload instantaneous | 10 In/5s or 20 In/1s |
Burden | < 0,1 VA |
Rated value | < 2 0 mΩ |
GENERAL FEATURES | |
---|---|
Case material | ABS, UL94 V0 |
Dimensions | DIN 96 x 96 mm |
Terminals | Pluggable |
Max. wire section | 2,5 mm² General |
4 mm² Current(I) | |
Weight | 0,4 Kg |
Protection | IP 65 - front pane |
IP 20 - meter body | |
Operating temperature | -10 - 60 °C |
Storage temperature | -25 - 70 °C |
Relative humidity | 5 – 95 % |
AUXILIARY VOLTAGE | |
---|---|
Aux. V. AC/DC | 80 - 270 V |
Burden | < 10 VA |
OUTPUT | |
---|---|
Relay output | 250V/5A AC; 30V/5A DC |
Isolation | 2500 V AC |
Energy pulse width | 80 ± 20% ms |
RS-485 port | Modbus-RTU |
Baud rate | Up to 38400 bps programmable |
Connection | 2 wires |
Ethernet port * | TCP Modbus |
ACCURACY
PARAMETER | OPERATING RANGE | ACCURACY |
---|---|---|
Voltage | 2,5-120 % | 0,2 % |
Current | 0,005-6 A | 0,2 % |
Active power | 1-120 % | 0,2 %** |
Reactive power | 1-120 % | 0,2 %** |
Apparent power | 1-120 % | 0,2 %** |
Power factor | ± 0,5 % | 0,5 % |
Frequency | 45-65 Hz | ± 0,01 Hz |
Active energy | 5-120 % | Class 0,5 S |
Reactive energy | 5-120 % | Class 2 |
DIMENSIONS
CONNECTIONS
Send an inquiry
Are you interested in this product? Do you need additional information or individual pricing?
Contact us
Network Analyzer - AHM1
The AHM1 is designed to be used for the measurement and calculation of electrical variables such as voltage, current, frequency, power, power factor, energy, harmonic components, etc. Memory of 8 MB incorporated.
GENERAL FEATURES
- IN 96 x 96 mm.
- MEMORY 8 MB.
- THD on V and I.
- HARMONIC RMS (1-31).
- DIGITAL INPUT/OUTPUT.
- MAXIMUM DEMAND, A, kW, kVA, kvar.
- PROGRAMMABLE RATED V AND I.
- 4 QUADRANT MEASUREMENT.
- RS-485 PORT.
- MAXIMUM AND MINIMUM VALUES.
- ETHERNET TCP-IP (Optional).
ELECTRICAL PARAMETER | UNIT | L1 | L2 | L3 | TOTAL | MAX/MIN | DEMAND |
---|---|---|---|---|---|---|---|
Voltage (Phase - Neutral) | V, kV | | | | | ||
Voltage (Phase - Phase) | V, kV | | | | | ||
Current | A, kA | | | | | | |
Neutral current | A, kA | | |||||
Active power (P) | kW, MW, GW | | | | | | |
Reactive power (Q) | kvar, Mvar, Gvar | | | | | | |
Apparent power (S) | kVA | | | | | | |
Power factor (Cos φ) | PF | | | | | | |
Frequency | Hz | | | ||||
Import active energy (EP+) | Wh, M Wh, G Wh | | |||||
Export active energy (EP-) | kWh, M Wh, G wh | | |||||
Import reactive energy (Eq+) | kvarh, M varh ,G varh | | |||||
Export reactive energy (Eq-) | kvarh, M varh, G varh | | |||||
Hour meter | h: min | | |||||
THD Current and Voltage | A, V | | | | |||
Harmonic RMS-U and I (1-31) | % | | | | |||
Unbalanced -U and I | % | |
2 DIGITAL INPUTS
- See input state
- Select tariff (Up to 4 tariff available)
- Pulse counter
- Maximum demand synchronization
OVERLOAD
- 2 Vn x 10 s
- 1,2 Vn permanent
- 20 In x 1 s
- 2 In permanent
2 CONTACT OUTPUTS
- Alarms
- Energy pulses
- Remote mode
INPUT | |
---|---|
Rated voltage (Un) | 3 x 400 / 690 V AC |
Overload | 1,2 Un |
Impedance | 1MΩ |
Rated current (In) | 1 A and 5 A |
Overload continuous | 2 In |
Overload instantaneous | 10 In/5s or 20 In/1s |
Burden | < 0,1 VA |
Rated value | < 2 0 mΩ |
GENERAL FEATURES | |
---|---|
Case material | ABS, UL94 V0 |
Dimensions | DIN 96 x 96 mm |
Terminals | Pluggable |
Max. wire section | 2,5 mm² General |
4 mm² Current(I) | |
Weight | 0,4 Kg |
Protection | IP 65 - front pane |
IP 20 - meter body | |
Operating temperature | -10 - 60 °C |
Storage temperature | -25 - 70 °C |
Relative humidity | 5 – 95 % |
AUXILIARY VOLTAGE | |
---|---|
Aux. V. AC/DC | 80 - 270 V |
Burden | < 10 VA |
OUTPUT | |
---|---|
Relay output | 250V/5A AC; 30V/5A DC |
Isolation | 2500 V AC |
Energy pulse width | 80 ± 20% ms |
RS-485 port | Modbus-RTU |
Baud rate | Up to 38400 bps programmable |
Connection | 2 wires |
Ethernet port * | TCP Modbus |
ACCURACY
PARAMETER | OPERATING RANGE | ACCURACY |
---|---|---|
Voltage | 2,5-120 % | 0,2 % |
Current | 0,005-6 A | 0,2 % |
Active power | 1-120 % | 0,2 %** |
Reactive power | 1-120 % | 0,2 %** |
Apparent power | 1-120 % | 0,2 %** |
Power factor | ± 0,5 % | 0,5 % |
Frequency | 45-65 Hz | ± 0,01 Hz |
Active energy | 5-120 % | Class 0,5 S |
Reactive energy | 5-120 % | Class 2 |
DIMENSIONS
CONNECTIONS
Your review appreciation cannot be sent
Report comment
Report sent
Your report cannot be sent
Write your review
Review sent
Your review cannot be sent