-
BackX
-
Components
-
-
Category
-
Semiconductors
- Diodes
- Thyristors
-
Electro-insulated Modules
- Electro-insulated Modules | VISHAY (IR)
- Electro-insulated Modules | INFINEON (EUPEC)
- Electro-insulated Modules | Semikron
- Electro-insulated Modules | POWEREX
- Electro-insulated Modules | IXYS
- Electro-insulated Modules | POSEICO
- Electro-insulated Modules | ABB
- Electro-insulated Modules | TECHSEM
- Go to the subcategory
- Bridge Rectifiers
-
Transistors
- Transistors | GeneSiC
- SiC MOSFET Modules | Mitsubishi
- SiC MOSFET Modules | STARPOWER
- Module SiC MOSFET ABB’s
- IGBT Modules | MITSUBISHI
- Transistor Modules | MITSUBISHI
- MOSFET Modules | MITSUBISHI
- Transistor Modules | ABB
- IGBT Modules | POWEREX
- IGBT Modules | INFINEON (EUPEC)
- Silicon Carbide (SiC) semiconductor elements
- Go to the subcategory
- Gate Drivers
- Power Blocks
- Go to the subcategory
-
Electrical Transducers
-
Current Transducers | LEM
- Closed-Loop Current Transducers (C/L)
- Open-Loop Current Transducers (O/L)
- Current Transducers supplied with unipolar voltage
- 'Eta' Current Transducers
- Current Transducers - LF xx10 Series
- Current Transducers - LH Series
- Current Transducer - HOYL and HOYS Series
- Current Transducers - GO–SME & GO–SMS Series
- AUTOMOTIVE current transducers
- Go to the subcategory
-
Voltage Transducers | LEM
- Voltage Transducers - LV Series
- Voltage Transducers - DVL Series
- Precision Voltage Transducers with double magnetic core - CV Series
- Voltage Transducer for Traction - DV 4200/SP4
- Voltage Transducers - DVM Series
- Voltage Transducer - DVC 1000-P
- Voltage Transducers - DVC 1000 Series
- Go to the subcategory
- Precision Current Transducers | LEM
- Go to the subcategory
-
Current Transducers | LEM
-
Passive components (capacitors, resistors, fuses, filters)
- Resistors
-
Fuses
- Miniature Fuses for electronic circuits - ABC & AGC Series
- Tubular Fast-acting Fuses
- Time-delay Fuse Links with GL/GG & AM characteristics
- Ultrafast Fuse Links
- Fast-acting Fuses (British & American standard)
- Fast-acting Fuses (European standard)
- Traction Fuses
- High-voltage Fuse Links
- Go to the subcategory
- Capacitors
- EMI Filters
- Supercapacitors
- Power surge protection
- Go to the subcategory
-
Relays and Contactors
- Relays and Contactors - Theory
- 3-Phase AC Semiconductor Relays
- DC Semiconductor Relays
- Controllers, Control Systems and Accessories
- Soft Starters and Reversible Relays
- Electromechanical Relays
- Contactors
- Rotary Switches
-
Single-Phase AC Semiconductor Relays
- AC ONE PHASE RELAYS 1 series| D2425 | D2450
- One phase semiconductor AC relays CWA and CWD series
- One phase semiconductor AC relays CMRA and CMRD series
- One phase semiconductor AC relays - PS series
- Double and quadruple semiconductor AC relays - D24 D, TD24 Q, H12D48 D series
- One phase semiconductor relays - gn series
- Ckr series single phase solid state relays
- One phase AC semiconductor relays for DIN bus - ERDA I ERAA series
- 150A AC single phase relays
- Rail Mountable Solid State Relays With Integrated Heat Sink - ENDA, ERDA1 / ERAA1 series
- Go to the subcategory
- Single-Phase AC Semiconductor Relays for PCBs
- Interface Relays
- Go to the subcategory
- Cores and Other Inductive Components
- Heatsinks, Varistors, Thermal Protection
- Fans
- Air Conditioning, Accessories for Electrical Cabinets, Coolers
-
Batteries, Chargers, Buffer Power Supplies and Inverters
- Batteries, Chargers - Theoretical Description
- Modular Li-ion Battery Building Blocks, Custom Batteries, BMS
- Batteries
- Battery Chargers and Accessories
- Uninterruptible Power Supply and Buffer Power Supplies
- Inverters and Photovoltaic Equipments
- Energy storage
- Fuel cells
- Lithium-ion batteries
- Go to the subcategory
-
Automatics
- Futaba Drone Parts
- Limit Switches, Microswitches
- Sensors, Transducers
-
Infrared Thermometers (Pyrometers)
- IR-TE Series - Water-proof Palm-sized Radiation Thermometer
- IR-TA Series - Handheld Type Radiation Thermometer
- IR-H Series - Handheld Type Radiation Thermometer
- IR-BA Series - High-speed Compact Radiation Thermometer
- IR-FA Series - Fiber Optic Radiation Thermometer
- IR-BZ Series - Compact Infrared Thermometers
- Go to the subcategory
- Counters, Time Relays, Panel Meters
- Industrial Protection Devices
- Light and Sound Signalling
- Thermographic Camera
- LED Displays
- Control Equipments
-
Recorders
- Hybrid Recorders - AL3000 Series | CHINO
- Graphic Recorder - KR2000 Series | CHINO
- Ubiquitous Recorders - KR5000 Series | CHINO
- Palm-sized Temperature/Humidity Meters - HN-CH Series | CHINO
- Consumables for Recorders
- 71VR1 - Compact Paperless Recorder | M-SYSTEM
- Graphic Recorder - KR3000 Series | CHINO
- PC Recorders - R1M Series | M-SYSTEM
- PC Recorders - R2M Series | M-SYSTEM
- PC Recorders - RZMS Series | M-SYSTEM
- PC Recorders - RZUS Series | M-SYSTEM
- Go to the subcategory
- Go to the subcategory
-
Cables, Litz wires, Conduits, Flexible connections
- Wires
- Litz wires
- Cables for extreme applications
- Sleevings
-
Braids
- Flat Braids
- Round Braids
- Very Flexible Flat Braids
- Very Flexible Round Braids
- Cylindrical Cooper Braids
- Cylindrical Cooper Braids and Sleevings
- Flexible Earthing Connections
- Galvanized and Stainless Steel Cylindrical Braids
- PCV Insulated Copper Braids (temp. up to 85C)
- Flat Aluminium Braids
- Junction Set - Braids and Tubes
- Go to the subcategory
- Traction Equipment
- Cable Terminals
- Flexible Insulated Busbars
- Flexible Multilayer Busbars
- Cable Duct Systems
- Hoses
- Go to the subcategory
- View all categories
-
Semiconductors
-
-
- Suppliers
-
Applications
- CNC Machine Tools
- DC and AC Drives (Inverters)
- Energetics
- Energy bank
- Equipment and Components for Hazardous Areas [Ex]
- Equipment for Distribution, Control and Telecommunications Cabinets
- HVAC Automation
- Induction Heating
- Industrial Automation
- Industrial Protective Devices
- Machines for Drying and Wood Processing
- Machines for Thermoforming Plastics
- Mining, Metallurgy and Foundry
- Motors and Transformers
- Power Supplies (UPS) and Rectifier Systems
- Printing
- Temperature Measurement and Regulation
- Test and Laboratory Measurements
- Tram and Railway Traction
- Welding Machines
-
Assembly
-
-
Montaż urządzeń
- Assembly of equipment on request
- Designing and Assembling of Busbar Cabinets, Switching Cabinets, Power Cabinets
- Power systems installation
- Components
- Machines built for order
- R&D research and development work
-
Industrial Testers
- Tester for diodes and thyristors measurement
- Thermal and motor circuit breakers testing stand
- Varistors and surge protectors testers
- Car fuses testing stand
- Tester for the power diode and thyristor reverse recovery charge Qrr measurement
- Rotor tester FD series
- Circuit breakers tester
- Tester for calibrating relays
- Video inspection tester for gas spring piston rods
- High-current thyristor switch
- Mesh ripping tester
- Go to the subcategory
- View all categories
-
-
-
Inductors
-
-
Modernizacja induktorów
- Repair of used inductors
- Modernization of inductors
-
Production of new inductors
- Inductors for crankshaft hardening
- Hardening of band saw teeth
- Inductors for heating elements before gluing
- Hardening of raceways of automotive wheel hub bearings
- Hardening of the drive transmission components
- Hardening of stepped shafts
- Heating in contraction joints
- Induction for scanning hardening
- Soft soldering
- Billet heaters
- Go to the subcategory
- Knowledge base
- View all categories
-
-
-
Induction devices
-
-
Urządzenia indukcyjne
-
Induction heating generators
-
Induction Heating Products Ambrell
- Generators power 500 W, frequency 150 - 400 kHz
- Generators power 1.2 - 2.4 kW, frequency 150 - 400 kHz
- Generators power 4.2 - 10 kW, frequency 150 - 400 kHz
- Generators power 10-15 kW, frequency 50-150 kHz
- Generators power 30-45 kW, frequency 50-150 kHz
- Generators power 65-135 kW, frequency 50-150 kHz
- Generators power 180-270 kW, frequency 50-150 kHz
- Generators power 20-35-50 kW, frequency 15-45 kHz
- Generators power 75-150 kW, frequency 15-45 kHz
- Generators power 200-500 kW, frequency 15-45 kHz
- Generators power 20-50 kW, frequency 5-15 kHz
- Go to the subcategory
- Induction heating products Denki Kogyo
-
JKZ induction heating generators
- Generators CX, frequency: 50-120kHz, power: 5-25kW
- Generators SWS, frequency: 15-30kHz, power: 25-260kW
- Molding and forging furnaces MFS, frequency: 0,5-10kHz, power: 80-500kW
- Melting metals furnaces MFS, frequency: 0,5-10kHz, power: 70-200kW
- Generators UHT, frequency: 200-400kHz, power: 10-160kW
- Go to the subcategory
- Lamp generators for induction heating
- Induction Heating Products - Himmelwerk
- Go to the subcategory
-
Induction Heating Products Ambrell
- Repairs and modernization
- Peripherals
-
Applications
- Medical Applications with Precision Induction Heating
- Applications for automotive industry
- Soldering
- Brazing
- Aluminum Brazing
- Brazing a magnetic steel cutting tool
- Pin Sealing
- Atmospheric Brazing
- Soldering brass and steel radiator caps
- Carbide Tipping
- Soldering a copper lug and a wire
- Go to the subcategory
- Knowledge base
- View all categories
-
Induction heating generators
-
-
-
Service
-
-
asd
- Service of industrial water coolers and air conditioners
- Machines Repairs and Modernizations
- Repair and Maintenance of Power Electronics, Electronic and Industrial Automation Devices
- HV Power Supplies for Electrostatic Precipitators
- Industrial Printers and Labelling Machines
- Certificates / Entitlements
- View all categories
-
-
- Contact
- Zobacz wszystkie kategorie
Photos are for informational purposes only. View product specification
please use latin characters
QNix® 4600
Rethinking coating thickness measurement QUALITY
With more than 100 measurements per minute, in terms of speed the QNix® 4600 can easily keep up with its measuring objects. Thanks to the handy and ergonomic design, the QNix® 4600 is in the vehicle appraisal in pole position.
The quick inspection of the paintwork succeeds reliably and accurately with the practical one-button operation. Without complex device configuration the QNix® 4600 provides precise measurement results.
Switch on, put on, read off. The large contact surface and the low centre of gravity ensure a safe placement and avoid incorrect measurements.
Whether it's powder coating or wet painting, the QNix® 4600 performs in the field of industrial painting and vehicle appraisal.
The brilliant 2" large colour LCD of the QNix® 4600 with its automatically flipping display makes readings of the measured values easier in any situation – even in low light conditions. The indication of average, standard deviation as well as the highest and lowest measured value provides all the necessary statistical information to the current series of measurements.
QNix® 4600 The Coating Thickness Gauge
TIME SAVING AND EASY OPERATION
- Automatic substrate detection
- High measuring speed: Put on, read off value
- Immediate evaluation of the readings by significant statistics
- No adjustment for standard applications needed
RELIABILITY OF VALUES THROUGH PRECISION AND CORRECTNESS
- High trueness over the entire range
- High repeatability of the measurement results
- Temperature compensation directly in the probe
PROCESS RELIABILITY AND READABILITY
- Brilliant IPS LCD, 2", colour, 350 cd / m2, viewing angle 70°
- Automatically flipping display 0°, 90°, 180°, 270°
- Low center of gravity with large contact surface for stable measurements
QNix® 4600 Scope of supply
Scope of supply of the QNix® 4600 Optional with Fe or Dual probe
- Gauge QNix® 4600
- Fe and NFe reference plate
- Calibration certificate
- Operation manual
- 2 Mignon batteries 1,5 V (AA) alkaline
- Plastic case for transport and storage
QNix® 4600 with automatically flipping display
Bright, 2" large colour display for an easy reading even under low light conditions
Measured value of the coating thickness in μm or mil
Average value
Maximum measured value of the current series of measurements
Minimum measured value of the current series of measurements
Standard deviation
Easy to use by one button
Large contact surface for a stable placement to avoid incorrect measurements
Automatically flipping display
Electrical details
Power supply | 2 × AA (batteries or rechargeable batteries) |
Battery life when gauge is not in use at min. 50 % battery capacity | > 1 year |
Battery life at one measurement per second | up to 40.000 readings |
Display | IPS-LCD, 2", colour, 350 cd / m2, viewing angle 70° all directions |
Weight and dimensions
Dimensions (H x W x D) | 135 × 63 × 43 mm |
Weight | 100 g |
Environmental conditions
Operating temperature | 0 °C to +50 °C / 32 °F to 122 °F |
Storage temperature | -20 °C to +70 °C / -4 °F to 158 °F |
Climatic conditions | 10 to 90 % relative humidity, non-condensing |
Metrological characteristics
Measuring principle | magnetic: magnetic field amendment / hall-effect Fe / eddy-current NFe |
Measuring speed (measurements per minute) | ≥ 100 |
Accuracy of measurement on Fe substrates related to QNix® reference standards | ± (1 μm + 2 % of the reading) to 2,0 mm ± 5 % of the reading from 2,0 mm |
Accuracy of measurement on NFe substrates related to QNix® reference standards | ± (2 μm + 2 % of the reading) to 2,0 mm ± 5 % of the reading from 2,0 mm |
Smallest measuring surface Fe / NFe | diameter 28 mm |
Smallest curvature konvex Fe | 10 mm – Zero point adjustment on original substrate (accuracy checked up to 250 μm) |
Smallest curvature konvex NFe | 50 mm – Zero point adjustment on original substrate (accuracy checked up to 250 μm) |
Minimum thickness of base metal Fe | 100 μm – Zero point adjustment on original substrate (accuracy checked up to 250 μm) |
Minimum thickness of base metal NFe | 50 μm – Zero point adjustment on original substrate (accuracy checked up to 250 μm) |
Send an inquiry
Are you interested in this product? Do you need additional information or individual pricing?
Contact us
QNix® 4600
Rethinking coating thickness measurement QUALITY
With more than 100 measurements per minute, in terms of speed the QNix® 4600 can easily keep up with its measuring objects. Thanks to the handy and ergonomic design, the QNix® 4600 is in the vehicle appraisal in pole position.
The quick inspection of the paintwork succeeds reliably and accurately with the practical one-button operation. Without complex device configuration the QNix® 4600 provides precise measurement results.
Switch on, put on, read off. The large contact surface and the low centre of gravity ensure a safe placement and avoid incorrect measurements.
Whether it's powder coating or wet painting, the QNix® 4600 performs in the field of industrial painting and vehicle appraisal.
The brilliant 2" large colour LCD of the QNix® 4600 with its automatically flipping display makes readings of the measured values easier in any situation – even in low light conditions. The indication of average, standard deviation as well as the highest and lowest measured value provides all the necessary statistical information to the current series of measurements.
QNix® 4600 The Coating Thickness Gauge
TIME SAVING AND EASY OPERATION
- Automatic substrate detection
- High measuring speed: Put on, read off value
- Immediate evaluation of the readings by significant statistics
- No adjustment for standard applications needed
RELIABILITY OF VALUES THROUGH PRECISION AND CORRECTNESS
- High trueness over the entire range
- High repeatability of the measurement results
- Temperature compensation directly in the probe
PROCESS RELIABILITY AND READABILITY
- Brilliant IPS LCD, 2", colour, 350 cd / m2, viewing angle 70°
- Automatically flipping display 0°, 90°, 180°, 270°
- Low center of gravity with large contact surface for stable measurements
QNix® 4600 Scope of supply
Scope of supply of the QNix® 4600 Optional with Fe or Dual probe
- Gauge QNix® 4600
- Fe and NFe reference plate
- Calibration certificate
- Operation manual
- 2 Mignon batteries 1,5 V (AA) alkaline
- Plastic case for transport and storage
QNix® 4600 with automatically flipping display
Bright, 2" large colour display for an easy reading even under low light conditions
Measured value of the coating thickness in μm or mil
Average value
Maximum measured value of the current series of measurements
Minimum measured value of the current series of measurements
Standard deviation
Easy to use by one button
Large contact surface for a stable placement to avoid incorrect measurements
Automatically flipping display
Electrical details
Power supply | 2 × AA (batteries or rechargeable batteries) |
Battery life when gauge is not in use at min. 50 % battery capacity | > 1 year |
Battery life at one measurement per second | up to 40.000 readings |
Display | IPS-LCD, 2", colour, 350 cd / m2, viewing angle 70° all directions |
Weight and dimensions
Dimensions (H x W x D) | 135 × 63 × 43 mm |
Weight | 100 g |
Environmental conditions
Operating temperature | 0 °C to +50 °C / 32 °F to 122 °F |
Storage temperature | -20 °C to +70 °C / -4 °F to 158 °F |
Climatic conditions | 10 to 90 % relative humidity, non-condensing |
Metrological characteristics
Measuring principle | magnetic: magnetic field amendment / hall-effect Fe / eddy-current NFe |
Measuring speed (measurements per minute) | ≥ 100 |
Accuracy of measurement on Fe substrates related to QNix® reference standards | ± (1 μm + 2 % of the reading) to 2,0 mm ± 5 % of the reading from 2,0 mm |
Accuracy of measurement on NFe substrates related to QNix® reference standards | ± (2 μm + 2 % of the reading) to 2,0 mm ± 5 % of the reading from 2,0 mm |
Smallest measuring surface Fe / NFe | diameter 28 mm |
Smallest curvature konvex Fe | 10 mm – Zero point adjustment on original substrate (accuracy checked up to 250 μm) |
Smallest curvature konvex NFe | 50 mm – Zero point adjustment on original substrate (accuracy checked up to 250 μm) |
Minimum thickness of base metal Fe | 100 μm – Zero point adjustment on original substrate (accuracy checked up to 250 μm) |
Minimum thickness of base metal NFe | 50 μm – Zero point adjustment on original substrate (accuracy checked up to 250 μm) |
Your review appreciation cannot be sent
Report comment
Report sent
Your report cannot be sent
Write your review
Review sent
Your review cannot be sent